Optimization of thermal and daylight performance of school buildings based on a multi-objective genetic algorithm in the cold climate of China

被引:178
作者
Zhang, Anxiao [1 ,2 ]
Bokel, Regina [2 ]
van den Dobbelsteenb, Andy [2 ]
Sun, Yanchen [1 ,2 ]
Huang, Qiong [1 ]
Zhang, Qi [1 ]
机构
[1] Tianjin Univ, Sch Architecture, Tianjin 300072, Peoples R China
[2] Delft Univ Technol, Fac Architecture & Built Environm, Delft, Netherlands
基金
中国国家自然科学基金;
关键词
School building; Energy demand; Adaptive thermal comfort; Useful daylight illuminance (UDI); Multi-objective optimization; China; Cold climate; INDOOR AIR-QUALITY; VISUAL COMFORT; ENERGY-CONSUMPTION; DESIGN; OFFICE; METRICS; SYSTEM;
D O I
10.1016/j.enbuild.2017.01.048
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A high demand for heating energy in winter, overheating in summer and visual discomfort are important issues in school buildings in the cold climate of China. This study presents the use of simulation-optimization tools to find the optimal trade-off between minimizing energy use for heating and lighting, reducing summer discomfort time and maximizing the Useful Daylight Illuminance (UDIavg, between 100 and 2000 lx). Different spatial configurations were investigated, including a single-sided open corridor type, a single-sided enclosed corridor type and a double-sided corridor type school. The following passive design parameters were considered in the optimization analysis: orientation, room depth and corridor depth, window-to -wall ratio of different interfaces, glazing materials and shading types. The results of the optimization study show that the energy demand for heating and lighting can be reduced by 24-28% and summer thermal discomfort by 9-23% while the UDIavg (100-2000 lx) can simultaneously increase by 15-63%. Considering all three aspects, the double-sided enclosed corridor type performs best due to its energy performance while the one-sided enclosed corridor type is the least suitable for the cold Climate because of its relatively poor visual comfort quality. In addition, the passive design parameters should be carefully considered as each spatial configuration has its own optimal passive design parameters. (C)2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:371 / 384
页数:14
相关论文
共 55 条
[1]  
A.S. ASHRAE, 2010, 9012010 ASASHRAE
[2]  
A.S. ASHRAE, 2010, 552010 ASASHARE
[3]   A review on simulation-based optimization methods applied to building performance analysis [J].
Anh-Tuan Nguyen ;
Reiter, Sigrid ;
Rigo, Philippe .
APPLIED ENERGY, 2014, 113 :1043-1058
[4]  
[Anonymous], 2011, 12665 EN
[5]  
[Anonymous], 1993, GB5107693
[6]  
[Anonymous], 1993, GB5107893
[7]  
Association Suisse des Electriciens, 1989, 418911 ASS SUISS EL
[8]  
Baker N., 2014, Daylight design of buildings: a handbook for architects and engineers
[9]   The impact of classroom design on pupils' learning: Final results of a holistic, multi-level analysis [J].
Barrett, Peter ;
Davies, Fay ;
Zhang, Yufan ;
Barrett, Lucinda .
BUILDING AND ENVIRONMENT, 2015, 89 :118-133
[10]   Improving energy performance of school buildings while ensuring indoor air quality ventilation [J].
Becker, Rachel ;
Goldberger, Itamar ;
Paciuk, Monica .
BUILDING AND ENVIRONMENT, 2007, 42 (09) :3261-3276