A comparison of hallux valgus angles assessed with computerised plantar pressure measurements, clinical examination and radiography in patients with diabetes

被引:22
|
作者
Janssen, Daniel M. C. [1 ]
Sanders, Antal P. [2 ]
Guldemond, Nick A. [3 ]
Hermus, Joris [1 ]
Walenkamp, Geert Him [1 ]
Van Rhijn, Lodewijk W. [1 ]
机构
[1] Maastricht Univ Med Ctr, Dept Orthopaed Surg, Maastricht, Netherlands
[2] Dorati Consultancy Feet & Hlth, The Hague, Netherlands
[3] Delft Univ Technol, Fac Elect Engn Math & Comp Sci, Dept Man machine Interact, Delft, Netherlands
来源
JOURNAL OF FOOT AND ANKLE RESEARCH | 2014年 / 7卷
关键词
3-STEP PROTOCOLS; MANCHESTER SCALE; FOOT STRUCTURE; RELIABILITY; VALIDATION; FOOTPRINT; VALIDITY; ANKLE; REPRODUCIBILITY; PREVALENCE;
D O I
10.1186/1757-1146-7-33
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Hallux valgus deformity is a common musculoskeletal foot disorder with a prevalence of 3.5% in adolescents to 35.7% in adults aged over 65 years. Radiographic measurements of hallux valgus angles (HVA) are considered to be the most reproducible and accurate assessment of HVA. However, in European countries, many podiatrists do not have direct access to radiographic facilities. Therefore, alternative measurements are desired. Such measurements are computerised plantar pressure measurement and clinical goniometry. The purpose of this study was to establish the agreement of these techniques and radiographic assessments. Methods: HVA was determined in one hundred and eighty six participants suffering from diabetes. Radiographic measurements of HVA were performed with standardised static weight bearing dorsoplantar foot radiographs. The clinical goniometry for HVA was measured with a universal goniometer. Computerised plantar pressure measurement for HVA was executed with the EMED SF-4 (R) pressure platform and Novel-Ortho-Geometry software. The intra-class correlation coefficients (ICC) and levels of agreement were analysed using Bland & Altman plots. Results: Comparison of radiographic measurements to clinical goniometry for HVA showed an intra-class correlation coefficient (ICC) of 0.81 (95% confidence interval, 0.76 to 0.86; p<0.001). Radiographic measurement versus computerised plantar pressure measurement showed an ICC of 0.59 (95% confidence interval, 0.49 to 0.68; p<0.001). In addition, clinical goniometry versus computerised plantar pressure measurement showed an ICC of 0.77 (95% confidence interval, 0.70 to 0.82; p<0.001). The systematic difference of the computerised plantar pressure measurement compared with radiographic measurement and clinical goniometry was 7.0 degrees (SD 6.8) and 5.2 degrees (SD 5.0), respectively. The systemic difference of radiographic measurements compared with clinical goniometry was 1.8 degrees (SD 5.0). Conclusions: The agreement of computerised plantar pressure measurement and clinical goniometry for HVA compared to radiographic measurement of HVA is unsatisfactory. Radiographic measurements of HVA and clinical goniometry for HVA yield better agreement compared to radiographic measurements and computerised plantar pressure measurement. The traditional radiographic measurement techniques are strongly recommended for the assessment of HVA.
引用
收藏
页数:9
相关论文
共 8 条
  • [1] The Comparison of Hallux Valgus Angles between Plain Radiography and Footprint Test
    Park, Jeong Mee
    Kim, Hyun Seok
    Kwon, Sung Joo
    Lee, Dong Wook
    Im, Hyung Tae
    ANNALS OF REHABILITATION MEDICINE-ARM, 2008, 32 (06): : 689 - 692
  • [2] Comparison of plantar pressure distribution in patients with hallux valgus and healthy matched controls
    Hida, Takashi
    Okuda, Ryuzo
    Yasuda, Toshito
    Jotoku, Tsuyoshi
    Shima, Hiroaki
    Neo, Masashi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (06) : 1054 - 1059
  • [3] Radiographic Angles in Hallux Valgus: Comparison Between Protractor and iPhone Measurements
    Meng, Hong-Zheng
    Zhang, Wei-Lin
    Li, Xiu-Cheng
    Yang, Mao-Wei
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (08) : 1250 - 1254
  • [4] Transfer of plantar pressure from the medial to the central forefoot in patients with hallux valgus
    Hofmann, Ulf Krister
    Goetze, Marco
    Wiesenreiter, Katharina
    Mueller, Otto
    Wuenschel, Markus
    Mittag, Falk
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [5] Radiographic Angles in Hallux Valgus: Comparison between Manual and Computer-Assisted Measurements
    Srivastava, Subodh
    Chockalingam, Nachiappan
    El Fakhri, Tarek
    JOURNAL OF FOOT & ANKLE SURGERY, 2010, 49 (06) : 523 - 528
  • [6] Comparison of Plantar Pressure Distribution Between Postoperative Hallux Valgus Feet and Healthy Feet
    Tsujinaka, Seiya
    Shima, Hiroaki
    Yasuda, Toshito
    Mori, Katsunori
    Kizawa, Momoko
    Togei, Kosho
    Neo, Masashi
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (05) : 578 - 585
  • [7] Comparison of 2D-3D Measurements of Hallux and First Ray Sagittal Motion in Patients With and Without Hallux Valgus
    Swanson, Jessica E.
    Stoltman, Matthew G.
    Oyen, Cheyenne R.
    Mohrbacher, Jessica A.
    Orandi, Atefeh
    Olson, Jeff M.
    Glasoe, Ward M.
    FOOT & ANKLE INTERNATIONAL, 2016, 37 (02) : 227 - 232
  • [8] Tonometric devices for central aortic systolic pressure measurements in patients with type 1 diabetes: comparison of the BPro and SphygmoCor devices
    Theilade, Simone
    Hansen, Tine W.
    Joergensen, Christel
    Lajer, Maria
    Rossing, Peter
    BLOOD PRESSURE MONITORING, 2013, 18 (03) : 156 - 160