The magnetics diagnostic set for ITER

被引:9
作者
Chavan, R. [1 ]
Chitarin, G. [4 ,5 ]
Delogu, R. S. [4 ]
Encheva, A. [6 ]
Gallo, A. [4 ]
Hodgson, E. R. [3 ]
Ingesson, L. C. [7 ]
Le-Luyer, A. [2 ]
Lister, J. B. [1 ]
Moreau, Ph. [2 ]
Moret, J. -M. [1 ]
Peruzzo, S. [4 ]
Romero, J. [3 ]
Testa, D. S. [1 ]
Toussaint, M. [1 ]
Vayakis, G. [6 ]
Vila, R. [3 ]
机构
[1] Ecole Polytech Fed Lausanne, Ctr Rech Phys Plasmas, Assoc EURATOM Confederat Suisse, CH-1015 Lausanne, Switzerland
[2] CEA DSM IRFM, Assoc Euratom CEA, F-13108 St Paul Les Durance, France
[3] CIEMAT Assoc EURATOM, E-28040 Madrid, Spain
[4] Consorzio RFX Assoc EURATOM ENEA, I-35127 Padua, Italy
[5] Univ Padua, Dept Engn & Management, I-36100 Vicenza, Italy
[6] ITER Org, F-13108 St Paul Les Durance, France
[7] EFDA CSU, D-85748 Garching, Germany
关键词
ITER; Magnetics; Diagnostic; MHD;
D O I
10.1016/j.fusengdes.2008.12.103
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The current status of the ITER magnetics diagnostic is summarised. The various risks are discussed on the basis of when they could be present during ITER operation and appropriate mitigation is reviewed. An implementation risk or common mode operation failure risk to the magnetic diagnostic can only be mitigated by diversity. All identified risks are being handled with ongoing research and development to minimise these risks. A reasonable level of design and manufacturing diversity has been therefore introduced in the procurement and installation plans, in order to optimise overall reliability avoiding dispersion of resources. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:295 / 299
页数:5
相关论文
共 15 条
[1]  
COSTLEY AE, 2008, ITP621 IAEA
[2]   Chapter 7: Diagnostics [J].
FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein, Netherlands ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 .
Nucl Fusion, 2007, 6 (S337-S384) :S337-S384
[3]   Diagnostics for steady state plasmas [J].
Hartfuss, H-J ;
Koenig, R. ;
Werner, A. .
PLASMA PHYSICS AND CONTROLLED FUSION, 2006, 48 (10) :R83-R150
[4]   Continuous data acquisition with online analysis for the Wendelstein 7-X magnetic diagnostics [J].
Hennig, Ch. ;
Werner, A. ;
Marquardt, M. ;
Bluhm, I. ;
Kroiss, H. ;
Kuehner, G. ;
Heimann, P. ;
Maier, J. ;
Riemann, H. ;
Zilker, M. .
FUSION ENGINEERING AND DESIGN, 2008, 83 (2-3) :321-325
[5]  
KURIHARA K, 1997, P 17 IEEE NPSS S FUS
[6]  
LANGEVOORT DC, 2004, WM MARY L REV, V46, P1
[7]   Magnetic measurements on the TCV Tokamak [J].
Moret, JM ;
Buhlmann, F ;
Fasel, D ;
Hofmann, F ;
Tonetti, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (06) :2333-2348
[8]   Fast single loop diamagnetic measurements on the TCV tokamak [J].
Moret, JM ;
Buhlmann, F ;
Tonetti, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (11) :4634-4643
[9]   Radiation-induced thermoelectric sensitivity in the mineral-insulated cable of magnetic diagnostic coils for ITER [J].
Nishitani, T ;
Vayakis, G ;
Yamauchi, M ;
Sugie, T ;
Kondoh, T ;
Shikama, T ;
Ishitsuka, E ;
Kawashima, H .
JOURNAL OF NUCLEAR MATERIALS, 2004, 329 :1461-1465
[10]  
ROGERS AJ, 1998, INT J OPTOELECTRON, V3, P391