Single reading with computer-aided detection performed by selected radiologists in a breast cancer screening program

被引:22
作者
Bargallo, Xavier [1 ]
Santamaria, Gorane [1 ]
del Amo, Montse [1 ]
Arguis, Pedro [1 ]
Rios, Jose [3 ]
Grau, Jaume [2 ]
Burrel, Marta [1 ]
Cores, Enrique [1 ]
Velasco, Martin [1 ]
机构
[1] Hosp Clin Barcelona, Dept Radiol CDIC, E-08036 Barcelona, Spain
[2] Hosp Clin Barcelona, Prevent Med & Epidemiol Unit, E-08036 Barcelona, Spain
[3] Hosp Clin Barcelona, Biostat & Data Management Core Facil, IDIBAPS, E-08036 Barcelona, Spain
关键词
Mammography; Breast screening; Breast neoplasms; Computer assisted diagnosis; Breast; DIAGNOSTIC MAMMOGRAPHY; DETECTION SYSTEM; RECALL RATES; BENEFIT;
D O I
10.1016/j.ejrad.2014.08.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the impact of shifting from a standard double reading plus arbitration protocol to a single reading by experienced radiologists assisted by computer-aided detection (CAD) in a breast cancer screening program. Methods: This was a prospective study approved by the ethics committee. Data from 21,321 consecutive screening mammograms in incident rounds (2010-2012) were read following a single reading plus CAD protocol and compared with data from 47,462 consecutive screening mammograms in incident rounds (2004-2010) that were interpreted following a double reading plus arbitration protocol. For the single reading, radiologists were selected on the basis of the appraisement of their previous performance. Results: Period 2010-2012 vs. period 2004-2010: Cancer detection rate (CDR): 6.1%. (95% confidence interval: 5.1-7.2) vs. 5.25%.; Recall rate (RR): 7.02% (95% confidence interval: 6.7-7.4) vs. 7.24% (selected readers before arbitration) and vs. 3.94 (all readers after arbitration); Predictive positive value of recall: 8.69% vs. 13.32%. Average size of invasive cancers: 14.6 +/- 9.5 mm vs. 14.3 +/- 9.5 mm. Stage: 0(22.3/26.1%); 1(59.2/50.8%); 11 (19.2/17.1%); III (3.1/3.3%); IV (0/1.9%). Specialized breast radiologists performed better than general radiologists. Conclusions: The cancer detection rate of the screening program improved using a single reading protocol by experienced radiologists assisted by CAD, at the cost of a moderate increase of the recall rate mainly related to the lack of arbitration. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2019 / 2023
页数:5
相关论文
共 27 条
[1]  
Agencia de Salut Publica de Barcelona, 2011, DROP
[2]   Summary of the evidence of breast cancer service screening outcomes in Europe and first estimate of the benefit and harm balance sheet [J].
Ancelle-Park, R. ;
Armaroli, P. ;
Ascunce, N. ;
Bisanti, L. ;
Bellisario, C. ;
Broeders, M. ;
Cogo, C. ;
de Koning, H. ;
Duffy, S. W. ;
Frigerio, A. ;
Giordano, L. ;
Hofvind, S. ;
Jonsson, H. ;
Lynge, E. ;
Massat, N. ;
Miccinesi, G. ;
Moss, S. ;
Naldoni, C. ;
Njor, S. ;
Nystrom, L. ;
Paap, E. ;
Paci, E. ;
Patnick, J. ;
Ponti, A. ;
Puliti, D. ;
Segnan, N. ;
Von Karsa, L. ;
Tornberg, S. ;
Zappa, M. ;
Zorzi, M. .
JOURNAL OF MEDICAL SCREENING, 2012, 19 :5-13
[3]  
[Anonymous], 2008, STAT METHODS MED RES
[4]   Breast cancer screening: characteristics and results of the Spanish programs [J].
Ascunce, Nieves ;
Delfrade, Josu ;
Salas, Dolores ;
Zubizarreta, Raquel ;
Ederra, Maria .
MEDICINA CLINICA, 2013, 141 (01) :13-23
[5]   Role of Computer-Aided Detection in Very Small Screening Detected Invasive Breast Cancers [J].
Bargallo, Xavier ;
Velasco, Martin ;
Santamaria, Gorane ;
del Amo, Montse ;
Arguis, Pedro ;
Sanchez Gomez, Sonia .
JOURNAL OF DIGITAL IMAGING, 2013, 26 (03) :572-577
[6]   Computer-aided detection in direct digital full-field mammography: initial results [J].
Baum, F ;
Fischer, U ;
Obenauer, S ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (12) :3015-3017
[7]   Computer-aided detection with screening mammography in a university hospital setting [J].
Birdwell, RL ;
Bandodkar, P ;
Ikeda, DM .
RADIOLOGY, 2005, 236 (02) :451-457
[8]   The Preponderance of Evidence Supports Computer-aided Detection for Screening Mammography [J].
Birdwell, Robyn L. .
RADIOLOGY, 2009, 253 (01) :9-16
[9]   Identifying Minimally Acceptable Interpretive Performance Criteria for Screening Mammography [J].
Carney, Patricia A. ;
Sickles, Edward A. ;
Monsees, Barbara S. ;
Bassett, Lawrence W. ;
Brenner, R. James ;
Feig, Stephen A. ;
Smith, Robert A. ;
Rosenberg, Robert D. ;
Bogart, T. Andrew ;
Browning, Sally ;
Barry, Jane W. ;
Kelly, Mary M. ;
Tran, Khai A. ;
Miglioretti, Diana L. .
RADIOLOGY, 2010, 255 (02) :354-361
[10]   Second reading of screening mammograms increases cancer detection and recall rates. Results in the Florence screening programme [J].
Ciatto, S ;
Ambrogetti, D ;
Bonardi, R ;
Catarzi, S ;
Risso, G ;
Del Turco, MR ;
Mantellini, P .