Prognostic value of gradient echo T2*sequences for brain MR imaging in preterm infants

被引:7
|
作者
de Bruine, Francisca T. [1 ]
Steggerda, Sylke J. [2 ]
van den Berg-Huysmans, Annette A. [1 ]
Leijser, Lara M. [2 ]
Rijken, Monique [2 ]
van Buchem, Mark A. [1 ]
van Wezel-Meijler, Gerda [2 ]
van der Grond, Jeroen [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Pediat, Subdiv Neonatol, NL-2300 RC Leiden, Netherlands
关键词
Gradient echo sequences; Hemosiderin deposits; Preterm infant; Term-equivalent age; Neurodevelopmental outcome; Magnetic resonance imaging; POSTHEMORRHAGIC VENTRICULAR DILATATION; PREMATURE-INFANTS; CEREBRAL-PALSY; WHITE-MATTER; INTRAVENTRICULAR HEMORRHAGE; CEREBELLAR HEMORRHAGE; CLINICAL-APPLICATIONS; CEREBROSPINAL-FLUID; INJURY; ULTRASOUND;
D O I
10.1007/s00247-013-2803-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Gradient echo T2*-W sequences are more sensitive than T2-W spin-echo sequences for detecting hemorrhages in the brain. The aim of this study is to correlate presence of hemosiderin deposits in the brain of very preterm infants (gestational age < 32 weeks) detected by T2*-W gradient echo MRI to white matter injury and neurodevelopmental outcome at 2 years. In 101 preterm infants, presence and location of hemosiderin were assessed on T2*-W gradient echo MRI performed around term-equivalent age (range: 40-60 weeks). White matter injury was defined as the presence of > 6 non-hemorrhagic punctate white matter lesions (PWML), cysts and/or ventricular dilatation. Six infants with post-hemorrhagic ventricular dilatation detected by US in the neonatal period were excluded. Infants were seen for follow-up at 2 years. Univariate and regression analysis assessed the relation between presence and location of hemosiderin, white matter injury and neurodevelopmental outcome. In 38/95 (40%) of the infants, hemosiderin was detected. Twenty percent (19/95) of the infants were lost to follow-up. There was a correlation between hemosiderin in the ventricular wall with > 6 PWML (P < 0.001) and cysts (P < 0.001) at term-equivalent age, and with a lower psychomotor development index (PDI) (P=0.02) at 2 years. After correcting for known confounders (gestational age, gender, intrauterine growth retardation and white matter injury), the correlation with PDI was no longer significant. The clinical importance of detecting small hemosiderin deposits is limited as there is no independent association with neurodevelopmental outcome.
引用
收藏
页码:305 / 312
页数:8
相关论文
共 50 条
  • [31] High incidence of microbleeds in hemodialysis patients detected by T2*-weighted gradient-echo magnetic resonance imaging
    Yokoyama, S
    Hirano, H
    Uomizu, K
    Kajiya, Y
    Tajitsu, K
    Kusumoto, K
    NEUROLOGIA MEDICO-CHIRURGICA, 2005, 45 (11) : 556 - 560
  • [32] Susceptibility artifact morphology is more conspicuous on susceptibility-weighted imaging compared to T2 gradient echo sequences in the brains of dogs and cats with suspected intracranial disease
    La Rosa, Claudia
    Donato, Pamela Di
    Specchi, Swan
    Bernardini, Marco
    VETERINARY RADIOLOGY & ULTRASOUND, 2023, 64 (03) : 464 - 472
  • [33] MEASUREMENT OF BRAIN ACTIVITY WITH BOLUS ADMINISTRATION OF CONTRAST AGENT AND GRADIENT-ECHO MR IMAGING
    ZIGUN, JR
    FRANK, JA
    BARRIOS, FA
    JONES, DW
    FOO, TKF
    MOONEN, CTW
    PRESS, DZ
    WEINBERGER, DR
    RADIOLOGY, 1993, 186 (02) : 353 - 356
  • [34] Chronic T2 Lesions in Multiple Sclerosis are Heterogeneous Regarding Phase MR Imaging
    Siemonsen, S.
    Young, K. L.
    Bester, M.
    Sedlacik, J.
    Heesen, C.
    Fiehler, J.
    Stellmann, J. -P.
    CLINICAL NEURORADIOLOGY, 2016, 26 (04) : 457 - 464
  • [35] MRI of acute post-ischemic cerebral hemorrhage in stroke patients:: diagnosis with T2*-weighted gradient-echo sequences
    Hermier, M
    Nighoghossian, N
    Derex, L
    Bethezène, Y
    Blanc-Lasserre, K
    Trouillas, P
    Froment, JC
    NEURORADIOLOGY, 2001, 43 (10) : 809 - 815
  • [36] MRI of acute post-ischemic cerebral hemorrhage in stroke patients: diagnosis with T2*-weighted gradient-echo sequences
    M. Hermier
    N. Nighoghossian
    L. Derex
    Y. Berthezène
    K. Blanc-Lasserre
    P. Trouillas
    J. C. Froment
    Neuroradiology, 2001, 43 : 809 - 815
  • [37] Magnetic resonance imaging of short T2 relaxation components in tissue using ultrashort echo time (UTE) pulse sequences
    Bydder, M
    Znamirowski, RM
    Bydder, GM
    CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (01) : 79 - 90
  • [38] Quantification of liver iron concentration with magnetic resonance imaging by combining T1-, T2-weighted spin echo sequences and a gradient echo sequence
    Kreeftenberg, HG
    Mooyaart, EL
    Huizenga, JR
    Sluiter, WJ
    Kreeftenberg, HG
    NETHERLANDS JOURNAL OF MEDICINE, 2000, 56 (04) : 133 - 137
  • [39] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [40] DIFFERENTIAL-DIAGNOSIS OF BENIGN AND MALIGNANT VERTEBRAL COMPRESSION FRACTURES WITH MR IMAGING - VALUE OF ANTIPHASED LONG TR GRADIENT-ECHO SEQUENCES, STIR SEQUENCES AND GD-DTPA
    STABLER, A
    KRIMMEL, K
    SEIDERER, M
    GARTNER, C
    FRITSCH, S
    RAUM, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (03): : 215 - 221