Performance and reliability comparison of French vertical flow treatment wetlands with other decentralized wastewater treatment technologies in tropical climates

被引:3
作者
Lombard-Latune, Remi [1 ]
Leriquier, Florent [1 ]
Oucacha, Chafatayne [1 ]
Pelus, Lucas [2 ]
Lacombe, Gerald [3 ]
Le Guennec, Bernard [4 ]
Molle, Pascal [1 ]
机构
[1] INRAE, UR Reversaal Reduce Reuse & Recycle Resources Was, 5 Rue Doua CS 20244, F-69625 Villeurbanne, France
[2] ODE, Martin Water Off, 7 Ave Condorcet,BP32-97201, Fort De France, Martinique, France
[3] Etiage Guyane, 4 Rue Coulicous, F-97354 Remire Montjoly, Guyane, France
[4] French Agcy Biodivers, AFB, Nadar Hall C,5 Allee Felix Nadar, F-94300 Vincennes, France
关键词
activated sludge; coefficient of reliability; constructed wetland; facultative pond; rotating biological contactor; CONSTRUCTED WETLANDS; DEVELOPING-COUNTRIES; SEWAGE; SYSTEM;
D O I
10.2166/wst.2020.444
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When implementing a sanitation system, the selection of treatment process can be difficult. Beyond removal efficiency and effluent concentrations, reliability should be taken into account. This study compares reliability of French vertical flow treatment wetlands (F-VFTW) with the four main decentralized wastewater treatment technologies in small communities in the French Overseas Territories (FOT). Analysis of 963 regulatory self-monitoring sampling campaigns performed on 213 wastewater treatment plants show that operational disruptions due to sludge loss and loss of nitrification are often reported for activated sludge technology; rotating biological contactors often suffer from weak settlement; facultative pond removal is limited by algae; and F-VFTW fulfills all the French regulatory objectives at a frequency of 90 to 95%. In addition, the data from this study are compared to a similar database from Brazil using a statistical approach (coefficient of reliability). Amongst the eight decentralized wastewater treatment technologies evaluated, F-VFTW appears to be the most appropriate for achieving the discharge standard with a reliability close to 95%. Its reliability to face both environmental (rainfall) and social (maintenance capacities) constraints is a key parameter.
引用
收藏
页码:1701 / 1709
页数:9
相关论文
共 24 条
[1]   Implementation of constructed wetlands in developing countries [J].
Denny, P .
WATER SCIENCE AND TECHNOLOGY, 1997, 35 (05) :27-34
[2]  
Dotro G., 2017, Treatment Wetlands, V7
[3]  
Haberl R, 1999, WATER SCI TECHNOL, V40, P11, DOI 10.2166/wst.1999.0126
[4]   The potential for constructed wetlands for wastewater treatment and reuse in developing countries: a review [J].
Kivaisi, AK .
ECOLOGICAL ENGINEERING, 2001, 16 (04) :545-560
[5]   Performance of a single stage vertical flow constructed wetland system treating raw domestic sewage in Brazil [J].
Lana, L. C. O. ;
Moraes, D. C. ;
von Sperling, M. ;
Morato, M. L. N. ;
Vasconcellos, G. R. ;
Paraense, M. O. ;
Moreira, T. P. A. .
WATER SCIENCE AND TECHNOLOGY, 2013, 68 (07) :1599-1606
[6]   Which plants are needed for a French vertical-flow constructed wetland under a tropical climate? [J].
Latune, R. Lombard ;
Laporte-Daube, O. ;
Fina, N. ;
Peyrat, S. ;
Pelus, L. ;
Molle, P. .
WATER SCIENCE AND TECHNOLOGY, 2017, 75 (08) :1873-1881
[7]   Resilience and reliability of compact vertical-flow treatment wetlands designed for tropical climates [J].
Lombard-Latune, R. ;
Pelus, L. ;
Fina, N. ;
L'Etang, F. ;
Le Guennec, B. ;
Molle, P. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 642 :208-215
[8]  
Lombard-Latune R., 2019, THESIS
[9]  
Lombard-Latune R., 2017, FRENCH BIODIVERSITY
[10]   First stage of the French vertical flow constructed wetland system: experiments with the reduction of surface area and number of units [J].
Manjate, E. S. ;
Lana, L. C. O. ;
Moraes, D. C. ;
Vasconcellos, G. R. ;
Maciel, G. R. M. ;
von Sperling, M. .
JOURNAL OF WATER SANITATION AND HYGIENE FOR DEVELOPMENT, 2015, 5 (01) :50-55