Ergonomic Evaluation of the Scrub Nurse's Posture at Different Monitor Positions During Laparoscopic Cholecystectomy

被引:8
作者
Papp, Andras [1 ]
Feussner, Hubertus [3 ]
Seitz, Thomas [2 ]
Bubb, Heiner [2 ]
Schneider, Armin [3 ]
Horvath, Ors Petet [1 ]
Vereczkei, Andras [1 ]
机构
[1] Univ Pecs, Fac Med, Dept Surg, H-7624 Pecs, Hungary
[2] Tech Univ Munich, Dept Ergon, D-8046 Garching, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Surg, Arbeitsgrp MITI, D-8000 Munich, Germany
关键词
ergonomic study; minimally invasive surgery; scrub nurse; different monitor placements; SURGERY; DESIGN;
D O I
10.1097/SLE.0b013e3181987c48
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Our aims were to measure the posture and movement of the scrub nurse very accurately, without using any markers, during a minimally invasive surgical procedure. Summary Background Data: One of the most important Subjects in ergonomic studies of minimally invasive surgery is the question of the proper placement of monitors. Method: Two simultaneous and synchronized video recordings were carried out in 2 different monitor setups. The different steps of the operation were identified and measured in seconds. Longer-lasting postures were imported to and analyzed with a software. Results of the different setups were compared with each other, and with an "ideal" comfort posture. Results: Measuring the typical postures of the most pronounced static phase, the evolving stress was significantly influenced by different monitor setups. Conclusions: With the installation of an additional monitor positioned to satisfy the nurse's comfort, the static stress could be decreased.
引用
收藏
页码:165 / 169
页数:5
相关论文
共 14 条
[1]  
ARNDT R, 1983, AM IND HYG ASSOC J, V44, P437, DOI 10.1080/15298668391405102
[2]   Ergonomic problems associated with laparoscopic surgery [J].
Berguer, R ;
Forkey, DL ;
Smith, WD .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (05) :466-468
[3]  
Burlington D B, 1996, Biomed Instrum Technol, V30, P107
[4]  
CUSCHIERI A, 1995, AM J SURG, V1, P9
[5]  
GILBRETH F., 1916, CAN J MED SURG, V40, P22
[6]   The minimally invasive surgical suite enters the 21st century -: A discussion of critical design elements [J].
Herron, DM ;
Gagner, M ;
Kenyon, TL ;
Swanström, LL .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (04) :415-422
[7]   Olympus integrated endosurgery system [J].
Imagawa, K ;
Furihata, H .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1998, 7 (05) :443-447
[8]  
KADEFORS F, 1982, MED PROG TECHNOL, V9, P149
[9]   DIRECTION OF GAZE AND COMFORT - DISCOVERING THE RELATION FOR THE ERGONOMIC OPTIMIZATION OF VISUAL TASKS [J].
MENOZZI, M ;
VONBUOL, A ;
KRUEGER, H ;
MIEGE, C .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1994, 14 (04) :393-399
[10]   Self-guided robotic camera control for laparoscopic surgery compared with human camera control [J].
Omote, K ;
Feussner, H ;
Ungeheuer, A ;
Arbter, K ;
Wei, GQ ;
Siewert, JR ;
Hirzinger, G .