Linear Mandibular Measurements: Comparison Between Orthopantomograms and Lateral Cephalograms

被引:29
|
作者
Ongkosuwito, E. M. [1 ]
Dieleman, M. M. J. [2 ]
Kuijpers-Jagtman, A. M. [3 ,4 ]
Mulder, P. G. H. [5 ]
van Neck, J. W. [6 ]
机构
[1] Univ Med Ctr, Erasmus MC, Dept Orthodont, Rotterdam, Netherlands
[2] Univ Med Ctr, Erasmus MC, Dept Plast & Reconstruct Surg, Rotterdam, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Orthodont & Oral Biol, Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Med Ctr, Cleft Palate Craniofacial Unit, Nijmegen, Netherlands
[5] Univ Med Ctr, Erasmus MC, Dept Epidemiol & Biostat, Rotterdam, Netherlands
[6] Univ Med Ctr, Erasmus MC, Dept Plast & Reconstruct Surg, Res Unit, Rotterdam, Netherlands
关键词
cephalometry; craniofacial; facial asymmetry; mandible; orthodontics; orthopantomography (OPT); reproducibility of results; ROTATIONAL PANORAMIC RADIOGRAPHY; HEAD FILM MEASUREMENTS; HEMIFACIAL MICROSOMIA; CEPHALOMETRIC LANDMARKS; REPRODUCIBILITY; ASYMMETRY; IDENTIFICATION; RELIABILITY; IMAGES; ERROR;
D O I
10.1597/07-123.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective; To investigate the reliability of length measurements of the mandible by comparing orthopantomograms (OPTs) with lateral cephalograms. Design: Observational study. Setting: OPTs and lateral cephalograms were taken of 20 human dry skulls. Four orthodontists and four maxillofacial surgeons located landmarks on all radiographs using a computer program for cephalometric measurements. Intraobserver and Interobserver variability in locating landmarks was assessed, as well as positioning of the skulls prior to radiography between the x-ray assistants. Magnification differences between the left and right side of the mandible on the OPT were determined for five skulls. Kappa statistics were used to calculate the Intraclass correlation coefficient for intraobserver and interobserver differences. An F test was used to assess differences between methods and between type of observer. Results: No significant differences were found in the magnification factor of the left and right side of the mandible. Compared with a lateral cephalogram, the OPT had comparable reliability in measuring mandibular distances condylion-gonion, gonion-menton, and condylion-menton. No significant differences were observed between the x-ray assistants in taking the OPTs and lateral cephalograms or In repositioning the skulls. Significant differences were found between orthodontists and maxillofacial surgeons for landmark measurements. Conclusion: An OPT is as reliable as a lateral cephalogram for linear measurements of the mandible (condylion-gonion, gonion-menton, and condylion-menton).
引用
收藏
页码:147 / 153
页数:7
相关论文
共 50 条
  • [1] Comparison of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms
    Yang, S.
    Liu, D. G.
    Gu, Y.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (07)
  • [2] Comparison of the soft tissue orthodontic analysis measurements between conventional lateral cephalograms and CBCT derived lateral cephalograms.
    Khanehmasjedi, Mashallah
    Miresmaili, Amirfarhang
    Jafari, Sanaz
    Khanehmasjedi, Samaneh
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (03): : 1087 - 1090
  • [3] Precision of measurements on conventional negative 'bones white' and inverted greyscale 'bones black' digital lateral cephalograms
    Borrie, Felicity
    Thomson, Donald
    McIntyre, Grant T.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (01) : 57 - 61
  • [4] Associations of Digital Measurements: Analysis of Orthopantomography Versus Lateral Cephalograms for Evaluation of Facial Asymmetry
    Stancioiu, Andra-Alexandra
    Motofelea, Alexandru Catalin
    Husanu, Anca Adriana
    Vasica, Lorena
    Nagib, Riham
    Popa, Adelina
    Szuhanek, Camelia
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [5] A comparative analysis of angular cephalometric values between CBCT generated lateral cephalograms versus digitized conventional lateral cephalograms
    Chung, Raymond-R.
    Lagravere, Manuel-O.
    Flores-Mir, Carlos
    Heo, Giseon
    Carey, Jason P.
    Major, Paul-W.
    INTERNATIONAL ORTHODONTICS, 2009, 7 (04) : 308 - 321
  • [6] Comparison of linear and angular measurements in mandibular symphyseal region using lateral cephalometric and cone beam CT images
    Baydar, Oguzhan
    Onem, Erinc
    Baksi, B. Guniz
    ORAL SCIENCE INTERNATIONAL, 2024, 21 (02) : 237 - 243
  • [7] Comparison of Mandibular Volume and Linear Measurements in Patients with Mandibular Asymmetry
    Hikosaka, Yuki
    Koizumi, So
    Kim, Yong-Il
    Adel, Mohamed
    Nadim, Mohamed
    Hikita, Yu
    Yamaguchi, Tetsutaro
    DIAGNOSTICS, 2023, 13 (07)
  • [8] Accuracy of Gonial Angle Measurements Using Panoramic Imaging versus Lateral Cephalograms in Adults with Different Mandibular Divergence Patterns
    Tashkandi, Nada E.
    Alnaqa, Najla Hamad
    Al-Saif, Naif M.
    Allam, Eman
    JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2024, 17 : 1923 - 1929
  • [9] Comparison of conventional lateral cephalograms with corresponding CBCT radiographs
    Park, Chang-Seo
    Park, Jae-Kyu
    Kim, Huijun
    Han, Sang-Sun
    Jeong, Ho-Gul
    Park, Hyok
    IMAGING SCIENCE IN DENTISTRY, 2012, 42 (04) : 201 - 205
  • [10] Accuracy of linear measurements using three imaging modalities: two lateral cephalograms and one 3D model from CBCT data
    Pittayapat, Pisha
    Bornstein, Michael M.
    Nozu Imada, Thais Sumie
    Coucke, Wim
    Lambrichts, Ivo
    Jacobs, Reinhilde
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (02) : 202 - 208