Measurement of dose enhancement close to high atomic number media using optical fibre thermoluminescence dosimeters

被引:5
作者
Alalawi, Amani I. [1 ,2 ]
Hugtenburg, R. P. [3 ,4 ]
Rahman, A. T. Abdul [5 ]
Barry, M. A. [6 ]
Nisbet, A. [1 ,6 ]
Alzimami, Khalid S. [1 ,7 ]
Bradley, D. A. [1 ,8 ]
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[2] Umm AL Qura Univ, Dept Phys, Mecca, Saudi Arabia
[3] Swansea Univ, Abertawe Bro Morgannwg UHB, Dept Med Phys & Clin Engn, Swansea SA2 8PP, W Glam, Wales
[4] Swansea Univ, Sch Med, Swansea SA2 8PP, W Glam, Wales
[5] Univ Teknol MARA, Sch Phys & Mat Studies, Kuala Pilah 72000, Malaysia
[6] Royal Surrey Cty Hosp NHS Trust, Dept Med Phys, Guildford GU2 7XX, Surrey, England
[7] King Saud Univ, Dept Radiol Sci, Riyadh 11432, Saudi Arabia
[8] Univ Malaya, Dept Phys, Kuala Pilah 72000, Malaysia
关键词
Dose enhancement; Thermoluminescence dosimeter; Monte Carlo simulation;
D O I
10.1016/j.radphyschem.2013.05.017
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Present interest concerns development of a system to measure photoelectron-enhanced dose close to a tissue interface using analogue gold-coated doped silica-fibre thermoluminescence detectors and an X-ray set operating at 250 kVp. Study is made of the dose enhancement factor for various thicknesses of gold; measurements at a total gold thickness of 160 nm (accounting for incident and exiting photons) produces a mean measured dose enhancement factor of 1.33 +/- 0.01 To verify results, simulations of the experimental setup have been performed. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:145 / 147
页数:3
相关论文
共 9 条
[1]  
[Anonymous], 2005, SLACR773, DOI DOI 10.2172/877507
[2]  
Battistoni G., 2007, AIP C P
[3]  
Bradley DA, 2007, AIP CONF PROC, V909, P9, DOI 10.1063/1.2739819
[4]  
MAINEGRA E., 2012, Graphical user interface for EGSnrc RZ user codes, V1.0
[5]   IODINE CONTRAST-MEDIUM SENSITIZES CULTURED MAMMALIAN-CELLS TO X-RAYS BUT NOT TO GAMMA-RAYS [J].
MATSUDAIRA, H ;
UENO, AM ;
FURUNO, I .
RADIATION RESEARCH, 1980, 84 (01) :144-148
[6]   SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes [J].
Poludniowski, G. ;
Landry, G. ;
DeBlois, F. ;
Evans, P. M. ;
Verhaegen, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19) :N433-N438
[7]  
Sauter F, 1931, ANN PHYS-BERLIN, V9, P217
[9]   Etch rates for micromachining processing - Part II [J].
Williams, KR ;
Gupta, K ;
Wasilik, M .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (06) :761-778