Restraint of fire-exposed concrete floor systems

被引:6
|
作者
Lim, L [1 ]
Buchanan, AH [1 ]
Moss, PJ [1 ]
机构
[1] Univ Canterbury, Christchurch, New Zealand
关键词
fire resistance; restraint; reinforced concrete; flat slabs; SAFIR;
D O I
10.1002/fam.854
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes the numerical analyses of restrained concrete floor slabs exposed to fire. The analyses of the slabs were carried out with the SAFIR finite element program considering a 200 mm thick slab, spanning 5 m between two end supports. The slabs were exposed to the ISO standard fire for up to 4 h and were analysed with pinned and rotationally restrained supports. Different heights of the line of thrust at the supports and different levels of axial restraint were also investigated. The analyses show that fully restrained pin-supported slabs can survive the 4h ISO fire without collapse if the position of the line of thrust is located near the soffit of the slab. If the position of the line of thrust is located much above the soffit of the slab, the slabs will rapidly undergo large deformations and sag into a catenary, imposing axial tensile forces at the supports. The analyses have shown that even if the line of thrust is located close to the soffit, the slab can still deform into a catenary if there is insufficient horizontal axial restraint. In this study, rotationally restrained slabs experience much smaller vertical deflections than pin-supported slabs when exposed to fires. Rotationally restrained slabs with low levels of horizontal restraint do not collapse, due to the beneficial effects of moment redistribution. However, high levels of horizontal restraint can be detrimental, causing slabs to collapse at advanced stages of the fire. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:95 / 125
页数:31
相关论文
共 50 条
  • [31] A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams
    Dwaikat, M. B.
    Kodur, V. K. R.
    FIRE SAFETY JOURNAL, 2008, 43 (04) : 291 - 307
  • [32] Finite element modeling of reinforced concrete beams exposed to fire
    Gao, W. Y.
    Dai, Jian-Guo
    Teng, J. G.
    Chen, G. M.
    ENGINEERING STRUCTURES, 2013, 52 : 488 - 501
  • [33] Effect of Load Ratios on the Behavior of Asymmetric Slim Floor Beams Exposed to Fire
    Park, Sooyoung
    Kim, Heungyoul
    Hong, Kappyo
    FIRE TECHNOLOGY, 2013, 49 (04) : 907 - 926
  • [34] TESTS OF RESIDUAL SHEAR TRANSFER STRENGTH OF CONCRETE EXPOSED TO FIRE
    Shallal, Muhaned A.
    Al Musawi, Aqil Mousa K.
    ARCHIVES OF CIVIL ENGINEERING, 2018, 64 (02) : 187 - 199
  • [35] Effect of Load Ratios on the Behavior of Asymmetric Slim Floor Beams Exposed to Fire
    Sooyoung Park
    Heungyoul Kim
    Kappyo Hong
    Fire Technology, 2013, 49 : 907 - 926
  • [36] Experimental study on the thermal behaviour of fire exposed slim-floor beams
    Albero, V
    Espinos, A.
    Serra, E.
    Romero, M. L.
    Hospitaler, A.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 819 - 823
  • [37] Experimental assessment of fire-exposed RC beam-column connections with varying reinforcement development lengths subjected to column removal
    Li, Zhi
    Liu, Yanzhi
    Huo, Jingsi
    Rong, Huang
    Chen, Jun
    Elghazouli, Ahmed Y.
    FIRE SAFETY JOURNAL, 2018, 99 : 38 - 48
  • [38] A Study on Fire Resistance of Reinforced Concrete-filled Square Steel Columns Exposed to Fire
    Park, Su Hee
    Song, Kyung Chul
    Choi, Sung Mo
    Won, Yong Ahn
    Bang, Joong Seck
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 501 - 508
  • [39] Effects of corrosion on the behaviour of precast concrete floor systems
    Cavaco, Eduardo S.
    Bastos, Afonso
    Santos, Filipe
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 145 : 411 - 418
  • [40] Numerical Modeling of Uniaxial Corroded Reinforced Concrete Columns Exposed to Fire
    Ba, Guangzhong
    Wu, Weijian
    Dai, Hongchao
    Jiao, Yu
    Zhang, Jie
    BUILDINGS, 2024, 14 (09)