Surgical wound debridement sequentially characterized in a porcine burn model with multispectral imaging

被引:36
作者
King, Darlene R. [1 ]
Li, Weizhi [1 ]
Squiers, John J. [1 ,2 ]
Mohan, Rachit [1 ]
Sellke, Eric [1 ]
Mo, Weirong [1 ]
Zhang, Xu [1 ]
Fan, Wensheng [1 ]
DiMaio, J. Michael [1 ,2 ]
Thatcher, Jeffrey E. [1 ]
机构
[1] Spectral MD Inc, Dallas, TX 75201 USA
[2] Baylor Univ, Med Ctr, Dallas, TX USA
关键词
Burns; Multispectral imaging; Debridement; Serial tangential excision; Medical imaging; Optics; HUMAN-SKIN; DEPTH; PREDICTION; EXCISION;
D O I
10.1016/j.burns.2015.05.009
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Multispectral imaging (MSI) is an optical technique that measures specific wavelengths of light reflected from wound site tissue to determine the severity of burn wounds. A rapid MSI device to measure burn depth and guide debridement will improve clinical decision making and diagnoses. Methodology: We used a porcine burn model to study partial thickness burns of varying severity. We made eight 4 x 4 cm burns on the dorsum of one minipig. Four burns were studied intact, and four burns underwent serial tangential excision. We imaged the burn sites with 400-1000 nm wavelengths. Results: Histology confirmed that we achieved various partial thickness burns. Analysis of spectral images show that MSI detects significant variations in the spectral profiles of healthy tissue, superficial partial thickness burns, and deep partial thickness burns. The absorbance spectra of 515, 542, 629, and 669 nm were the most accurate in distinguishing superficial from deep partial thickness burns, while the absorbance spectra of 972 nm was the most accurate in guiding the debridement process. Conclusion: The ability to distinguish between partial thickness burns of varying severity to assess whether a patient requires surgery could be improved with an MSI device in a clinical setting. (C) 2015 Elsevier Ltd and ISBI. All rights reserved.
引用
收藏
页码:1478 / 1487
页数:10
相关论文
共 28 条
[1]   CLINICAL-EVALUATION OF BURN INJURIES USING AN OPTICAL REFLECTANCE TECHNIQUE [J].
AFROMOWITZ, MA ;
VANLIEW, GS ;
HEIMBACH, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (02) :114-127
[2]  
American Burn Association, 2011, 2011 NAT BURN REP RE
[3]   THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[4]   MULTISPECTRAL PHOTOGRAPHIC ANALYSIS - NEW QUANTITATIVE TOOL TO ASSIST IN EARLY DIAGNOSIS OF THERMAL BURN DEPTH [J].
ANSELMO, VJ ;
ZAWACKI, BE .
ANNALS OF BIOMEDICAL ENGINEERING, 1977, 5 (02) :179-193
[5]   Planning for burn disasters: Lessons learned from one hundred years of history [J].
Barillo, David J. ;
Wolf, Steven .
JOURNAL OF BURN CARE & RESEARCH, 2006, 27 (05) :622-634
[6]   A porcine model of full-thickness burn, excision and skin autografting [J].
Branski, Ludwik K. ;
Mittermayr, Rainer ;
Herndon, David N. ;
Norbury, William B. ;
Masters, Oscar E. ;
Hofmann, Martina ;
Traber, Daniel L. ;
Redl, Heinz ;
Jeschke, Marc G. .
BURNS, 2008, 34 (08) :1119-1127
[7]   Reflection-optical multispectral imaging method for objective determination of burn depth [J].
Eisenbeiss, W ;
Marotz, J ;
Schrade, JP .
BURNS, 1999, 25 (08) :697-704
[8]  
Graham John S, 2005, J Burns Wounds, V4, pe1
[9]  
Gurfinkel R, 2010, CAN J PLAST SURG, V18, pE33
[10]  
HEIMBACH DM, 1987, SURG CLIN N AM, V67, P93