A Randomized Comparison of the Efficacy of 2 Techniques for Piriformis Muscle Injection Ultrasound-Guided Versus Nerve Stimulator With Fluoroscopic Guidance

被引:19
作者
Fowler, Ian M. [1 ]
Tucker, Anthony A. [2 ]
Weimerskirch, Brian P. [2 ]
Moran, Thomas J. [2 ]
Mendez, Robert J. [2 ]
机构
[1] Naval Med Ctr, Dept Anesthesia & Pain Med, San Diego, CA 92134 USA
[2] Naval Med Ctr, Dept Anesthesia & Pain Med, Portsmouth, VA USA
关键词
PAIN CLINICAL-TRIALS; INTERVENTIONAL PROCEDURES; DIAGNOSIS;
D O I
10.1097/AAP.0000000000000056
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Piriformis muscle injections are most often performed using fluoroscopic guidance; however, ultrasound (US) guidance has recently been described extensively in the literature. No direct comparisons between the 2 techniques have been performed. Our objective was to compare the efficacy and efficiency of fluoroscopic- and US-guided techniques. Methods: A randomized, comparative trial was carried out to compare the 2 techniques. Twenty-eight patients with a diagnosis of piriformis syndrome, based on history and physical examination, who had failed conservative treatment were enrolled in the study. Patients were randomized to receive the injection either via US or fluoroscopy. Injections consisted of 10 mL of 1% lidocaine with 80 mg of triamcinalone. The primary outcome measure was numeric pain score, and secondary outcome measures included functional status as measured by the Multidimensional Pain Inventory, patient satisfaction as measured by the Patient Global Impression of Change scale, and procedure timing characteristics. Outcome data were measured preprocedure, immediately postprocedure, and 1 to 2 weeks and 3 months postprocedure. Results: We found no statistically significant differences in numeric pain scores, patient satisfaction, procedure timing characteristics, or most functional outcomes when comparing the 2 techniques. Statistically significant differences between the 2 techniques were found with respect to the outcome measures of household chores and outdoor work. Conclusions: Ultrasound-guided piriformis injections provide similar outcomes to fluoroscopically guided injections without differences in imaging, needling, or overall procedural times.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 31 条
[1]  
[Anonymous], 1976, ECDEU ASSESSMENT MAN
[2]   PIRIFORMIS SYNDROME - A RATIONAL APPROACH TO MANAGEMENT [J].
BARTON, PM .
PAIN, 1991, 47 (03) :345-352
[3]  
Bellingham BA, 2013, REGION ANESTH PAIN M, V37, P262
[4]   Piriformis syndrome - Anatomic considerations, a new injection technique, and a review of the literature [J].
Benzon, HT ;
Katz, JA ;
Benzon, HA ;
Iqbal, MS .
ANESTHESIOLOGY, 2003, 98 (06) :1442-1448
[5]  
Betts Andres, 2004, Pain Physician, V7, P279
[6]   Piriformis syndrome: Correlation of muscle morphology with symptoms and signs [J].
Broadhurst, NA ;
Simmons, N ;
Bond, MJ .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (12) :2036-2039
[7]  
CHEN WS, 1994, PAIN, V58, P269, DOI 10.1016/0304-3959(94)90208-9
[8]   Botulinum toxin type A use in piriformis muscle syndrome - A pilot study [J].
Childers, MK ;
Wilson, DJ ;
Gnatz, SM ;
Conway, RR ;
Sherman, AK .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2002, 81 (10) :751-759
[9]  
Cleeland C. S., 1994, Annals Academy of Medicine Singapore, V23, P129
[10]   PIRIFORMIS MUSCLE SYNDROME - AN UNDERDIAGNOSED CAUSE OF SCIATICA [J].
DURRANI, Z ;
WINNIE, AP .
JOURNAL OF PAIN AND SYMPTOM MANAGEMENT, 1991, 6 (06) :374-379