A comparison of publicly available linear MRI stereotaxic registration techniques

被引:78
作者
Dadar, Mahsa [1 ]
Fonov, Vladimir S. [1 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, NeuroImaging & Surg Tools Lab, Montreal, PQ, Canada
基金
美国国家卫生研究院;
关键词
MRI; Linear registration; Quality control; IMAGE; PERFORMANCE; VALIDATION;
D O I
10.1016/j.neuroimage.2018.03.025
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Linear registration to a standard space is one of the major steps in processing and analyzing magnetic resonance images (MRIs) of the brain. Here we present an overview of linear stereotaxic MRI registration and compare the performance of 5 publicly available and extensively used linear registration techniques in medical image analysis. Methods: A set of 9693 T1-weighted MR images were obtained for testing from 4 datasets: ADNI, PREVENT-AD, PPMI, and HCP, two of which have multi-center and multi-scanner data and three of which have longitudinal data. Each individual native image was linearly registered to the MNI ICBM152 average template using five versions of MRITOTAL from MINC tools, FLIRT from FSL, two versions of Elastix, spm_affreg from SPM, and ANTs linear registration techniques. Quality control (QC) images were generated from the registered volumes and viewed by an expert rater to assess the quality of the registrations. The QC image contained 60 sub-images (20 of each of axial, sagittal, and coronal views at different levels throughout the brain) overlaid with contours of the ICBM152 template, enabling the expert rater to label the registration as acceptable or unacceptable. The performance of the registration techniques was then compared across different datasets. In addition, the effect of image noise, intensity non-uniformity, age, head size, and atrophy on the performance of the techniques was investigated by comparing differences between age, scaling factor, ventricle volume, brain volume, and white matter hyperintensity (WMH) volumes between passed and failed cases for each method. Results: The average registration failure rate among all datasets was 27.41%, 27.14%, 12.74%, 13.03%, 0.44% for the five versions of MRITOTAL techniques, 8.87% for ANTs, 11.11% for FSL, 12.35% for Elastix Affine, 24.40% for Elastix Similarity, and 30.66% for SPM. There were significant effects of signal to noise ratio, image intensity non-uniformity estimates, as well as age, head size, and atrophy related changes between passed and failed registrations. Conclusion: Our experiments show that the Revised BestLinReg had the best performance among the evaluated registration techniques while all techniques performed worse for images with higher levels of noise and non-uniformity as well as atrophy related changes.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 34 条
[1]   Incorporating prior knowledge into image registration [J].
Ashburner, J ;
Neelin, P ;
Collins, DL ;
Evans, A ;
Friston, K .
NEUROIMAGE, 1997, 6 (04) :344-352
[2]   A new method for structural volume analysis of longitudinal brain MRI data and its application in studying the growth trajectories of anatomical brain structures in childhood [J].
Aubert-Broche, B. ;
Fonov, V. S. ;
Garcia-Lorenzo, D. ;
Mouiha, A. ;
Guizard, N. ;
Coupe, P. ;
Eskildsen, S. F. ;
Collins, D. L. .
NEUROIMAGE, 2013, 82 :393-402
[3]   The Insight ToolKit image registration framework [J].
Avants, Brian B. ;
Tustison, Nicholas J. ;
Stauffer, Michael ;
Song, Gang ;
Wu, Baohua ;
Gee, James C. .
FRONTIERS IN NEUROINFORMATICS, 2014, 8
[4]   A reproducible evaluation of ANTs similarity metric performance in brain image registration [J].
Avants, Brian B. ;
Tustison, Nicholas J. ;
Song, Gang ;
Cook, Philip A. ;
Klein, Arno ;
Gee, James C. .
NEUROIMAGE, 2011, 54 (03) :2033-2044
[5]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[6]   Animal: Validation and applications of nonlinear registration-based segmentation [J].
Collins, DL ;
Evans, AC .
INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 1997, 11 (08) :1271-1294
[7]   An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images [J].
Coupe, Pierrick ;
Yger, Pierre ;
Prima, Sylvain ;
Hellier, Pierre ;
Kervrann, Charles ;
Barillot, Christian .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) :425-441
[8]   Robust Rician noise estimation for MR images [J].
Coupe, Pierrick ;
Manjon, Jose V. ;
Gedamu, Elias ;
Arnold, Douglas ;
Robles, Montserrat ;
Collins, D. Louis .
MEDICAL IMAGE ANALYSIS, 2010, 14 (04) :483-493
[9]  
Dadar M., 2017, IEEE T MED IMAGING
[10]   Validation of T1w-based segmentations of white matter hyperintensity volumes in large-scale datasets of aging [J].
Dadar, Mahsa ;
Maranzano, Josefina ;
Ducharme, Simon ;
Carmichael, Owen T. ;
Decarli, Charles ;
Collins, D. Louis .
HUMAN BRAIN MAPPING, 2018, 39 (03) :1093-1107