Study on Fault Mechanism of Lightning Flashover Based on EMTP - RV in Wind Farm

被引:1
|
作者
Zhang, Shi [1 ]
Zhang, Bo [1 ]
Xia, Hui [1 ]
Sun, Tong [1 ]
Zhai, Jinchuan [1 ]
Kong, Xiangqi [1 ]
Cao, Li [1 ]
Huo, Huanjie [1 ]
机构
[1] Longyuan Beijing Wind Power Engn Technol Co Ltd, Beijing 100034, Peoples R China
关键词
D O I
10.1088/1742-6596/1176/6/062020
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The particularity of lightning flashover failure of wind farm is analyzed, and it is pointed out that the formation mechanism of lightning overvoltage in wind farm collector system is different from that of power system distribution network. On this basis, the mechanism of lightning flashover failure of wind farm collector system is analyzed. The EMTP-RV software is used to simulate the typical lightning overvoltage formation and propagation process of the wind farm collector system. Results show that the fault mechanism of the lightning flashover fault system is analyzed. Finally, it is pointed out that the design scheme of the insulation system of the wind farm collection system should not directly copy the design scheme of the distribution network of the power system.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Research on Asymmetric Fault Location of Wind Farm Collection System Based on Compressed Sensing
    Yu H.
    Han G.
    Luo H.
    Wang H.
    Energy Engineering: Journal of the Association of Energy Engineering, 2023, 120 (09): : 2029 - 2057
  • [22] GROUND FAULT DIAGNOSIS METHOD FOR WIND FARM BASED ON C-DWT AND FFNN
    Zhang C.
    Gao X.
    Yan L.
    Wang X.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (11): : 393 - 398
  • [23] Fault Location Method of Wind Farm Collection Line Based on Vector Deviation Degree
    Zhang K.
    Sun L.
    Zhu Y.
    Liu X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (10): : 127 - 133
  • [24] Fault Phase Selection Method for Interconnection Line of DFIG-based Wind Farm
    Wang Z.
    Xiao F.
    Wang Y.
    Zhang Z.
    Yin X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2018, 42 (08): : 170 - 176
  • [25] Wind farm earth fault protection scheme based on real-time communication
    Chen, Guoqi
    Duan, Bin
    Yang, Xianyou
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (04): : 92 - 96
  • [26] Study of wind farm control potential based on SCADA data
    Schreiber, J.
    Salbert, B.
    Bottasso, C. L.
    SCIENCE OF MAKING TORQUE FROM WIND (TORQUE 2018), 2018, 1037
  • [27] Application of Parallel Resonance Fault Current Limiter for Fault Ride Through Capability Augmentation of DFIG Based Wind Farm
    Rashid, Gilmanur
    Ali, Mohd Hasan
    2016 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2016,
  • [28] Analysis of lightning transient performance of 132 kV transmission line connected to Miramar wind farm: A case study
    Zalhaf, Amr S.
    Han, Yang
    Yang, Ping
    Wang, Congling
    Khan, Muhammad Ammar
    ENERGY REPORTS, 2022, 8 : 257 - 265
  • [29] Study on lightning protection of collector line in wind farm by multi-fracture active arc extinguishing device
    Huang, Ping
    Wang, Sen
    Wang, Guo-feng
    Wang, Ju-feng
    Zheng, Jin-pao
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 213
  • [30] Arc flash fault detection in wind farm collection feeders based on current waveform analysis
    Bin WANG
    Jiang NI
    Jianzhao GENG
    Yuanyuan LU
    Xinzhou DONG
    Journal of Modern Power Systems and Clean Energy, 2017, 5 (02) : 211 - 219