Study on Fault Mechanism of Lightning Flashover Based on EMTP - RV in Wind Farm

被引:1
|
作者
Zhang, Shi [1 ]
Zhang, Bo [1 ]
Xia, Hui [1 ]
Sun, Tong [1 ]
Zhai, Jinchuan [1 ]
Kong, Xiangqi [1 ]
Cao, Li [1 ]
Huo, Huanjie [1 ]
机构
[1] Longyuan Beijing Wind Power Engn Technol Co Ltd, Beijing 100034, Peoples R China
关键词
D O I
10.1088/1742-6596/1176/6/062020
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The particularity of lightning flashover failure of wind farm is analyzed, and it is pointed out that the formation mechanism of lightning overvoltage in wind farm collector system is different from that of power system distribution network. On this basis, the mechanism of lightning flashover failure of wind farm collector system is analyzed. The EMTP-RV software is used to simulate the typical lightning overvoltage formation and propagation process of the wind farm collector system. Results show that the fault mechanism of the lightning flashover fault system is analyzed. Finally, it is pointed out that the design scheme of the insulation system of the wind farm collection system should not directly copy the design scheme of the distribution network of the power system.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Lightning Fault Rate of Power Distribution Line in Wind Farm in Winter Lightning Area
    Michishita, Koji
    Yokoyama, Shigeru
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 1377 - 1389
  • [2] EMTP RV-based study of Solid-State Fault Current Limiter for distribution systems
    Sood, V. K.
    Amin, R.
    Salam, M.
    2006 IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2006, : 733 - +
  • [3] Safety of Wind Farm Grounding Systems under Fault and Lightning Currents
    Grange, Francois
    Journet, Sebastien
    Moini, Rouzbeh
    Dawalibi, Farid Paul
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [4] Lightning Transient Analysis of Offshore Wind Turbine Based on ATP-EMTP
    Zhang P.
    Wu X.
    Zhao X.
    Zhang W.
    Liu N.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (12): : 4266 - 4273
  • [5] A study on the analysis of lightning damage impact in domestic offshore wind farm
    Seo J.-G.
    Kim K.-H.
    Kim, Kyu-Ho (kyuho@hknu.ac.kr), 2016, Korean Institute of Electrical Engineers (65): : 247 - 252
  • [6] EMTP-based smart optimization of TCSC parameters oriented for mitigating wind farm SSO
    Huang, Jie
    Chen, Wuhui
    Dong, Deyong
    Tan, Lunnong
    Dianwang Jishu/Power System Technology, 2015, 39 (09): : 2411 - 2417
  • [7] A Study of Comparative Fault Analysis & Fault Time in a UPFC Integrated Wind Farm
    Mishra, S. K.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2018, 8 (04): : 2239 - 2248
  • [8] Study of Lightning Intruding Surge for 330kVGIS Substation Based on EMTP/ATP
    Wang Zhuo
    Wang Weiquan
    Wang Qiang
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 2329 - 2332
  • [9] A new method for spatial allocation of turbines in a wind farm based on lightning protection efficiency
    Zhang, Li
    Lao, Huanjing
    Wang, Guozheng
    Zou, Liang
    Zhao, Tong
    Fang, Zhiyang
    WIND ENERGY, 2019, 22 (10) : 1310 - 1323
  • [10] Voltage Transient Study of Wind Farm under Power System Fault
    Zhang, Xin-yan
    Wang, Wei-qing
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 169 - +