Raman Analysis of Tear Fluid Alteration Following Contact Lense Use

被引:18
作者
Capaccio, Angela [1 ]
Sasso, Antonio [1 ,2 ]
Rusciano, Giulia [1 ,2 ]
机构
[1] Univ Naples Federico II, Complesso Univ Monte S Angelo, Dept Phys E Pancini, Via Cintia, I-80126 Naples, Italy
[2] CNR, INO, Via Campi Flegrei 34, I-80078 Pozzuoli, NA, Italy
关键词
tear fluid; Raman Spectroscopy; contact lens wearing; SPECTROSCOPY; INFORMATION;
D O I
10.3390/s19153392
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tear fluid is a heterogeneous solution containing mainly proteins, lipids, mucins and electrolytes, which regulates the physiology of the human eye. The complex composition of tears can be altered in the presence of eye inflammations. The use of contact lenses is one of the most frequent causes of inflammatory responses of the eye, with the related discomfort often causing the wearer to give up using them. In this paper, we exploit the potentiality of Raman Spectroscopy to analyse the biochemical changes in tear fluid in a contact lens wearer. In particular, we analysed the tear fluid collected from a volunteer as a function of the wearing time for two types of monthly contact lenses (Hydrogel and Si-Hydrogel). Our experimental results show an alteration of the relative concentrations of proteins and lipids in both of the analysed cases. More importantly, our results highlight the diagnostic sensitivity of Raman analysis to select the proper contact lens type for each wearer and optimise the lens wearing conditions.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Ammer R., 2017, PAK J OPHTHALMOL, V33, P182
  • [2] Understanding the molecular information contained in principal component analysis of vibrational spectra of biological systems
    Bonnier, F.
    Byrne, H. J.
    [J]. ANALYST, 2012, 137 (02) : 322 - 332
  • [3] Characterization of Human Tear Fluid by Means of Surface-Enhanced Raman Spectroscopy
    Camerlingo, Carlo
    Lisitskiy, Mikhail
    Lepore, Maria
    Portaccio, Marianna
    Montorio, Daniela
    Del Prete, Salvatore
    Cennamo, Gilda
    [J]. SENSORS, 2019, 19 (05)
  • [4] Label-Free Biochemical Analytic Method for the Early Detection of Adenoviral Conjunctivitis Using Human Tear Biofluids
    Choi, Samjin
    Moon, Sung Woon
    Shin, Jae-Ho
    Park, Hun-Kuk
    Jin, Kyung-Hyun
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (22) : 11093 - 11099
  • [5] Tear film lipid layer: A molecular level view
    Cwiklik, Lukasz
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2016, 1858 (10): : 2421 - 2430
  • [6] Analysis of human tear fluid by Raman spectroscopy
    Filik, J.
    Stone, N.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 616 (02) : 177 - 184
  • [7] Raman point mapping of tear ferning patterns - art. no. 685309
    Filik, Jacob
    Stone, Nicholas
    [J]. BIOMEDICAL OPTICAL SPECTROSCOPY, 2008, 6853 : 85309 - 85309
  • [8] Investigation into the protein composition of human tear fluid using centrifugal filters and drop coating deposition Raman spectroscopy
    Filik, Jacob
    Stone, Nicholas
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 2009, 40 (02) : 218 - 224
  • [9] Structure of water, proteins, and lipids in intact human skin, hair, and nail
    Gniadecka, M
    Nielsen, OF
    Christensen, DH
    Wulf, HC
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1998, 110 (04) : 393 - 398
  • [10] Golding T., 1989, CLIN EXP OPTOM, V72, P102, DOI DOI 10.1111/J.1444-0938.1989.TB03069.X