Biotite Reference Materials for Secondary Ion Mass Spectrometry 18O/16O Measurements

被引:19
|
作者
Siron, Guillaume [1 ]
Baumgartner, Lukas [1 ]
Bouvier, Anne-Sophie [1 ]
Putlitz, Benita [1 ]
Vennemann, Torsten [2 ]
机构
[1] Univ Lausanne, Inst Earth Sci, CH-1015 Lausanne, Switzerland
[2] Univ Lausanne, Inst Earth Surface Dynam, CH-1015 Lausanne, Switzerland
关键词
oxygen isotopes; secondary ion mass spectrometry; ion microprobe; biotite; reference material; OXYGEN-ISOTOPE RATIOS; HIGH-PRECISION; CL-OH; MINERALS; GARNET; MICAS; SILICATES; SIMS; MG; FE;
D O I
10.1111/ggr.12148
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Five new biotite reference materials were calibrated at the SwissSIMS laboratory (University of Lausanne) for oxygen isotope determination by secondary ion mass spectrometry (SIMS) and are available to the scientific community. The oxygen isotope composition of the biotites, UNIL_B1 to B5, was determined by laser-heating fluorination to be 11.4 +/- 0.11 parts per thousand, 8.6 +/- 0.15 parts per thousand, 6.1 +/- 0.04 parts per thousand, 7.1 +/- 0.05 parts per thousand and 7.6 +/- 0.04 parts per thousand, respectively. SIMS analyses on spots smaller than 20m gave a measurement repeatability of 0.3 parts per thousand (2 standard deviation, 2s). The matrix effect due to solid solution in natural biotite could be expressed as a linear function of X-Mg and X-F for biotite. No effect was found for different crystallographic orientations. SIMS analysis allows the oxygen isotope composition of biotite to be measured with a measurement uncertainty of 0.3-0.4 parts per thousand (2s) for biotites with similar major element compositions. A measurement uncertainty of 0.5 parts per thousand (2s) is realistic when F poor biotites (lower than 0.2% m/m oxides) within the compositional range of X-Mg of 0.3-0.9 were compared from different sessions. The linear correlation with F content offers a reasonable working curve for F-rich biotites, but additional reference materials are needed to confirm the model.
引用
收藏
页码:243 / 253
页数:11
相关论文
共 50 条
  • [41] CLUSTER SECONDARY ION MASS SPECTROMETRY OF POLYMERS AND RELATED MATERIALS
    Mahoney, Christine M.
    MASS SPECTROMETRY REVIEWS, 2010, 29 (02) : 247 - 293
  • [42] Speleothem annual layers revealed by seasonal SIMS δ18O measurements
    LIU YuHui
    TANG GuoQiang
    LING XiaoXiao
    HU ChaoYong
    LI XianHua
    Science China(Earth Sciences), 2015, 58 (10) : 1741 - 1747
  • [43] Speleothem annual layers revealed by seasonal SIMS δ18O measurements
    YuHui Liu
    GuoQiang Tang
    XiaoXiao Ling
    ChaoYong Hu
    XianHua Li
    Science China Earth Sciences, 2015, 58 : 1741 - 1747
  • [44] Two-point normalization for reducing inter-laboratory discrepancies in δ17O, δ18O, and Δ′17O of reference silicates
    Kim, Nak Kyu
    Park, Changkun
    Kusakabe, Minoru
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2020, 11 (01)
  • [45] Recovery and interpretation of the 18O/16O of Miocene oolitic goethites in multi-generational mixtures of Fe (III) oxides from a channel iron deposit of Western Australia
    Yapp, Crayton J.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2020, 279 : 143 - 164
  • [46] Seasonal changes in sea surface temperature and salinity during the Little Ice Age in the Caribbean Sea deduced from Mg/Ca and 18O/16O ratios in corals
    Watanabe, T
    Winter, A
    Oba, T
    MARINE GEOLOGY, 2001, 173 (1-4) : 21 - 35
  • [47] Changes in the 18O/16O ratios of fluids as evidence for different metamorphic episodes in high grade gneisses from the Konovalov Mountains area (Rayner Complex, East Antarctica)
    Krylov, DP
    Hoernes, S
    Bridgwater, D
    CHEMICAL GEOLOGY, 1998, 147 (3-4) : 295 - 312
  • [48] Combined Effects of Gametogenic Calcification and Dissolution on 18O Measurements of the Planktic Foraminifer Trilobatus sacculifer
    Wycech, Jody B.
    Kelly, Daniel Clay
    Kitajima, Kouki
    Kozdon, Reinhard
    Orland, Ian J.
    Valley, John W.
    GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2018, 19 (11): : 4487 - 4501
  • [49] Isotope ratio measurements by secondary ion mass spectrometry (SIMS) and glow discharge mass spectrometry (GDMS)
    Betti, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 169 - 182
  • [50] Correction of secondary ion mass spectrometry profiles for atom diffusion measurements
    Portavoce, A.
    Rodriguez, N.
    Daineche, R.
    Grosjean, C.
    Girardeaux, C.
    MATERIALS LETTERS, 2009, 63 (08) : 676 - 678