Biotite Reference Materials for Secondary Ion Mass Spectrometry 18O/16O Measurements

被引:19
|
作者
Siron, Guillaume [1 ]
Baumgartner, Lukas [1 ]
Bouvier, Anne-Sophie [1 ]
Putlitz, Benita [1 ]
Vennemann, Torsten [2 ]
机构
[1] Univ Lausanne, Inst Earth Sci, CH-1015 Lausanne, Switzerland
[2] Univ Lausanne, Inst Earth Surface Dynam, CH-1015 Lausanne, Switzerland
关键词
oxygen isotopes; secondary ion mass spectrometry; ion microprobe; biotite; reference material; OXYGEN-ISOTOPE RATIOS; HIGH-PRECISION; CL-OH; MINERALS; GARNET; MICAS; SILICATES; SIMS; MG; FE;
D O I
10.1111/ggr.12148
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Five new biotite reference materials were calibrated at the SwissSIMS laboratory (University of Lausanne) for oxygen isotope determination by secondary ion mass spectrometry (SIMS) and are available to the scientific community. The oxygen isotope composition of the biotites, UNIL_B1 to B5, was determined by laser-heating fluorination to be 11.4 +/- 0.11 parts per thousand, 8.6 +/- 0.15 parts per thousand, 6.1 +/- 0.04 parts per thousand, 7.1 +/- 0.05 parts per thousand and 7.6 +/- 0.04 parts per thousand, respectively. SIMS analyses on spots smaller than 20m gave a measurement repeatability of 0.3 parts per thousand (2 standard deviation, 2s). The matrix effect due to solid solution in natural biotite could be expressed as a linear function of X-Mg and X-F for biotite. No effect was found for different crystallographic orientations. SIMS analysis allows the oxygen isotope composition of biotite to be measured with a measurement uncertainty of 0.3-0.4 parts per thousand (2s) for biotites with similar major element compositions. A measurement uncertainty of 0.5 parts per thousand (2s) is realistic when F poor biotites (lower than 0.2% m/m oxides) within the compositional range of X-Mg of 0.3-0.9 were compared from different sessions. The linear correlation with F content offers a reasonable working curve for F-rich biotites, but additional reference materials are needed to confirm the model.
引用
收藏
页码:243 / 253
页数:11
相关论文
共 50 条
  • [31] 'Box-Profile' Ion Implants as Geochemical Reference Materials for Electron Probe Microanalysis and Secondary Ion Mass Spectrometry
    Wu, Haosheng
    Boettger, Roman
    Couffignal, Frederic
    Gutzmer, Jens
    Krause, Joachim
    Munnik, Frans
    Renno, Axel D.
    Huebner, Rene
    Wiedenbeck, Michael
    Ziegenruecker, Rene
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2019, 43 (04) : 531 - 541
  • [32] Metrology for stable isotope reference materials: 13C/12C and 18O/16O isotope ratio value assignment of pure carbon dioxide gas samples on the Vienna PeeDee Belemnite-CO2 scale using dual-inlet mass spectrometry
    Srivastava, Abneesh
    Verkouteren, R. Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (17) : 4153 - 4163
  • [33] δ18O measurements of archaeological glass (Roman to Modern age) and raw materials: possible interpretation
    Silvestri, Alberta
    Longinelli, Antonio
    Molin, Gianmario
    JOURNAL OF ARCHAEOLOGICAL SCIENCE, 2010, 37 (03) : 549 - 560
  • [34] Secondary Ion Mass Spectrometry and Time-of-Flight Secondary Ion Mass Spectrometry Study of Impurity Measurements in HgCdTe
    Steve Price
    Larry Wang
    Alice Wang
    Arwa Ginwalla
    Ian Mowat
    Journal of Electronic Materials, 2007, 36 : 1106 - 1109
  • [35] Secondary ion mass spectrometry and time-of-flight secondary ion mass spectrometry study of impurity measurements in HgCdTe
    Price, Steve
    Wang, Larry
    Wang, Alice
    Ginwalla, Arwa
    Mowat, Ian
    JOURNAL OF ELECTRONIC MATERIALS, 2007, 36 (08) : 1106 - 1109
  • [36] Ion microprobe δ18O analyses to calibrate slow growth rate speleothem records with regional δ18O records of precipitation
    Dominguez-Villar, David
    Lojen, Sonja
    Krklec, Kristina
    Kozdon, Reinhard
    Edwards, R. Lawrence
    Cheng, Hai
    EARTH AND PLANETARY SCIENCE LETTERS, 2018, 482 : 367 - 376
  • [37] Accessing the position-specific 18O/16O ratios of lignin monomeric units from higher plants with highly selective hydrogenolysis followed by GC/Py/IRMS analysis
    Wang, Ying
    Zhu, Zhenyu
    Xia, Yu
    Zhong, Muyang
    Ma, Ran
    Zhao, Yu
    Yan, Qiulin
    Miao, Qing
    Wang, Bo
    Ma, Yi
    Yin, Xijie
    Zhou, Youping
    ANALYTICA CHIMICA ACTA, 2021, 1171
  • [38] A Potential New Chalcopyrite Reference Material for Secondary Ion Mass Spectrometry Sulfur Isotope Ratio Analysis
    Li, Rucao
    Xia, Xiao-Ping
    Chen, Huayong
    Wu, Nanping
    Zhao, Taiping
    Lai, Chunkit
    Yang, Qing
    Zhang, Yanqiang
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2020, 44 (03) : 485 - 500
  • [39] Comparison of δ18O analyses on individual planktic foraminifer (Orbulina universa) shells by SIMS and gas- source mass spectrometry
    Wycech, Jody B.
    Kelly, Daniel Clay
    Kozdon, Reinhard
    Orland, Ian J.
    Spero, Howard J.
    Valley, John W.
    CHEMICAL GEOLOGY, 2018, 483 : 119 - 130
  • [40] Speleothem annual layers revealed by seasonal SIMS δ 18O measurements
    Liu Yuhui
    Tang GuoQiang
    Ling XiaoXiao
    Hu ChaoYong
    Li XianHua
    SCIENCE CHINA-EARTH SCIENCES, 2015, 58 (10) : 1741 - 1747