Comparison of radiographic and pQCT analyses of healing rat tibial fractures

被引:23
作者
Jämsä, T
Koivukangas, A
Kippo, K
Hannuniemi, R
Jalovaara, P
Tuukkanen, J
机构
[1] Univ Oulu, Tech Serv Unit, FIN-90401 Oulu, Finland
[2] Univ Oulu, Dept Surg, FIN-90401 Oulu, Finland
[3] Leiras Oy, Biomed Res Ctr, FIN-20101 Turku, Finland
[4] Univ Oulu, Dept Anat & Cell Biol, FIN-90401 Oulu, Finland
关键词
fracture healing; callus; quantitative tomography; X-ray densitometry; image analysis;
D O I
10.1007/s002230010058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fracture healing and callus formation have traditionally been evaluated by using X-ray radiography. Here we compared X-ray radiography and peripheral quantitative computed tomography (pQCT) in evaluating the healing callus of standardized tibial fractures in 141 female rats after a 4- or 8-week follow-up. The results were compared with the tensile (4-week) and compressive (8-week) failure load of the callus. The projectional size of callus, as defined from lateral ex vivo radiographs, correlated significantly with the pQCT-defined cross-sectional area (CSA) of mid-callus. This relationship was dependent on the pQCT attenuation threshold, being higher for the CSA of compact bone (r = 0.85, P < 0.0001) than for the total bone CSA (r = 0.68, P < 0.0001). Radiographically defined callus projectional area also correlated strongly with bone mineral content (BMC) (r = 0.84-0.86, P < 0.0001). The mean optical density of the callus analyzed from the radiographs had only a weak correlation with the pQCT-defined bone mineral density (BMD) of callus. A weak negative relationship was found between CSA and BMD. The optical density analyzed from lateral radiographs did not correlate with the tensile or compressive failure load of callus. Callus size, BMC, and BMD were associated with the compressive failure load, whereas both radiographs and pQCT were poor in explaining the failure load in tension.
引用
收藏
页码:288 / 291
页数:4
相关论文
共 23 条
  • [1] PREDICTION OF PROPERTIES OF FRACTURE CALLUS BY MEASUREMENT OF MINERAL DENSITY USING MICRO-BONE DENSITOMETRY[J]. ARO, HT;WIPPERMANN, BW;HODGSON, SF;WAHNER, HW;LEWALLEN, DG;CHAO, EYS. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989(07)
  • [2] ARONSON J, 1994, CLIN ORTHOP RELAT R, P25
  • [3] Quantitative assessment of experimental fracture repair by peripheral computed tomography[J]. Augat, P;Merk, J;Genant, HK;Claes, L. CALCIFIED TISSUE INTERNATIONAL, 1997(02)
  • [4] Accuracy of cortical and trabecular bone measurements with peripheral quantitative computed tomography (pQCT)[J]. Augat, P;Gordon, CL;Lang, TF;Iida, H;Genant, HK. PHYSICS IN MEDICINE AND BIOLOGY, 1998(10)
  • [5] Dual-energy x-ray absorptiometry as a measure of healing in fractures treated by intramedullary nailing[J]. Cattermole, HC;Fordham, JN;Muckle, DS;Cunningham, JL. JOURNAL OF ORTHOPAEDIC TRAUMA, 1996(08)
  • [6] Quantification of fracture healing with three-dimensional computed tomography[J]. den Boer, FC;Bramer, JAM;Patka, P;Bakker, FC;Barentsen, RH;Feilzer, AJ;de Lange, ESM;Haarman, HJTM. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998(6-7)
  • [7] Gasser J.A., 1995, BONE S, V17, P145
  • [8] Comparison of three-point bending test and peripheral quantitative computed tomography analysis in the evaluation of the strength of mouse femur and tibia[J]. Jämsä, T;Jalovaara, P;Peng, Z;Väänänen, HK;Tuukkanen, J. BONE, 1998(02)
  • [9] A cost-effective, accurate machine for testing the torsional strength of sheep long bones[J]. Jamsa, T;Jalovaara, P. MEDICAL ENGINEERING & PHYSICS, 1996(05)
  • [10] Femoral neck strength of mouse in two loading configurations:: method evaluation and fracture characteristics[J]. Jämsä, T;Tuukkanen, J;Jalovaara, P. JOURNAL OF BIOMECHANICS, 1998(08)