Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging

被引:7
|
作者
Higgins, John V. [1 ]
Watson, Robert E., Jr. [4 ]
Jaffe, Allan S. [3 ]
Dalzell, Connie [2 ]
Acker, Nancy [2 ]
Felmlee, Joel P. [4 ]
Asirvatham, Samuel J. [2 ]
Cha, Yong-Mei [2 ]
Friedman, Paul A. [2 ]
Kapa, Suraj [2 ,5 ]
机构
[1] Univ Nebraska Med Ctr, Cardiovasc Dis, Omaha, NE USA
[2] Mayo Clin, Heart Rhythm Serv, Rochester, MN 55905 USA
[3] Mayo Clin, Cardiovasc Dis, Rochester, MN 55905 USA
[4] Mayo Clin, Radiol, Rochester, MN 55905 USA
[5] Mayo Clin, Div Cardiovasc Dis, 200 First St SW, Rochester, MN 55905 USA
关键词
Magnetic resonance imaging; Cardiac pacemaker; Implantable cardioverter-defibrillator; Cardiac troponin; CARDIOVERTER-DEFIBRILLATORS; IN-VIVO; PERMANENT PACEMAKERS; 1.5; TESLA; SAFETY; LEADS; MRI; VITRO; ASSAY;
D O I
10.1007/s10840-015-0064-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has been safely performed in many patients with cardiac implantable electronic devices (CIEDs) using institution-specific protocols. A potential risk of MRI is myocardial heating and cardiac injury, which might be detectable with cardiac Troponin (cTn). We evaluated this in patients with CIEDs undergoing MRI. Prospective data were collected from 2008 to the present in patients with CIEDs undergoing clinically indicated MRI performed under institutional protocol. Cardiac Troponin T (cTnT) levels were drawn both before and 24-36 h after the procedure. The collective data were retrospectively analyzed. MRI exams (n = 512) were performed in 398 patients. Of these, there were 348 unique scans with cTnT recorded before and after MRI (median age 68, IQ 56-78; 62 % men). cTnT did not significantly change for the group as a whole (0.00 +/- 0.056). There were 22 (6.3 %) exams with cTnT change a parts per thousand yen0.002 ng/mL following MRI (range 0.01-0.09 ng/mL). There were no clinically significant events in these patients directly attributable to MR. There were no significant changes in pacing threshold or impedance in the group with elevated cardiac biomarkers. There are very few situations where myocardial injury as detected by cTnT in patients undergoing MRI with CIEDs could be detected. No adverse clinical events or functional changes of the device were noted, even in those with increases in cTnT. Our experience supports that MRI can be performed safely for appropriately selected patients under close clinical observation. Proactive monitoring with the present iteration of cardiac biomarkers appears to be of limited utility, but prospective monitoring with high sensitivity assays may be able to detect subclinical myocardial damage.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 50 条
  • [41] Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: best practice and real-world experience
    Seewoester, Timm
    Loebe, Susanne
    Hilbert, Sebastian
    Bollmann, Andreas
    Sommer, Philipp
    Lindemann, Frank
    Bacevicius, Justinas
    Schoene, Katharina
    Richter, Sergio
    Doering, Michael
    Paetsch, Ingo
    Hindricks, Gerhard
    Jahnke, Cosima
    EUROPACE, 2019, 21 (08): : 1220 - 1228
  • [42] Magnetic resonance imaging in patients with cardiac implantable electronic devices in a cardio-oncology center
    Tajstra, Mateusz
    Dyrbus, Maciej
    Wojtynek, Elzbieta
    Wojtaszczyk, Adam
    Rutkowski, Tomasz
    Niedziela, Jacek
    Blachut, Aleksandra
    Jarzab, Michal
    Blamek, Slawomir
    Kurek, Anna
    Gorol, Jaroslaw
    Witek, Mateusz
    Skladowski, Krzysztof
    Gasior, Mariusz
    Bobek-Bilewicz, Barbara
    KARDIOLOGIA POLSKA, 2023, 81 (06) : 619 - 621
  • [43] Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices
    Nazarian, Saman
    Hansford, Rozann
    Rahsepar, Amir A.
    Weltin, Valeria
    McVeigh, Diana
    Ipek, Esra Gucuk
    Kwan, Alan
    Berger, Ronald D.
    Calkins, Hugh
    Lardo, Albert C.
    Kraut, Michael A.
    Kamel, Ihab R.
    Zimmerman, Stefan L.
    Halperin, Henry R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2017, 377 (26) : 2555 - 2564
  • [44] Magnetic Resonance Myocardial Imaging in Patients With Implantable Cardiac Devices: Challenges, Techniques, and Clinical Applications
    Gut, Pauline
    Cochet, Hubert
    Stuber, Matthias
    Bustin, Aurelien
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2024, 41 (11):
  • [45] MRI in Patients with Cardiac Implantable Electronic Devices
    Muthalaly, Rahul G.
    Nerlekar, Nitesh
    Ge, Yin
    Kwong, Raymond Y.
    Nasis, Arthur
    RADIOLOGY, 2018, 289 (02) : 281 - 292
  • [46] Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices with generator and lead(s) brand mismatch
    Minaskeian, Nareg
    Hajnal, Sofia P.
    Liu, Michael B.
    Klooster, Lindsay M.
    Devick, Katrina L.
    Schwartz, Linda
    Jokerst, Clinton E.
    Sorajja, Dan
    Scott, Luis R. P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [47] State-of-the-art approach towards magnetic resonance imaging of the nervous system structures in patients with cardiac implantable electronic devices
    Gniadek-Olejniczak, Katarzyna
    Makowski, Karol
    Olszewski, Adam
    Tomczykiewicz, Kazimierz
    Krawczyk, Andrzej
    Mroz, Jozef
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2018, 52 (06) : 652 - 656
  • [48] Magnetic Resonance Imaging in People With Cardiac Implantable Electronic Devices: A Population Based Cohort Study
    Gillam, Marianne H.
    Inacio, Maria C. S.
    Pratt, Nicole L.
    Shakib, Sepehr
    Roughead, Elizabeth E.
    HEART LUNG AND CIRCULATION, 2018, 27 (06) : 748 - 751
  • [49] Cardiovascular Magnetic Resonance in Patients With Magnetic Resonance-Conditional Cardiac Implantable Electronic Devices What Can We See?
    Simonetti, Orlando P.
    Gross, David C.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (05)
  • [50] Cardiac MRI for Patients With Cardiac Implantable Electronic Devices
    Stojanovska, Jadranka
    Runge, Mason
    Mahani, Maryam Ghadimi
    Cronin, Paul P.
    Sayyouh, Mohamed
    Bogun, Frank
    Ibrahim, El-Sayed H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 374 - 381