Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging

被引:7
|
作者
Higgins, John V. [1 ]
Watson, Robert E., Jr. [4 ]
Jaffe, Allan S. [3 ]
Dalzell, Connie [2 ]
Acker, Nancy [2 ]
Felmlee, Joel P. [4 ]
Asirvatham, Samuel J. [2 ]
Cha, Yong-Mei [2 ]
Friedman, Paul A. [2 ]
Kapa, Suraj [2 ,5 ]
机构
[1] Univ Nebraska Med Ctr, Cardiovasc Dis, Omaha, NE USA
[2] Mayo Clin, Heart Rhythm Serv, Rochester, MN 55905 USA
[3] Mayo Clin, Cardiovasc Dis, Rochester, MN 55905 USA
[4] Mayo Clin, Radiol, Rochester, MN 55905 USA
[5] Mayo Clin, Div Cardiovasc Dis, 200 First St SW, Rochester, MN 55905 USA
关键词
Magnetic resonance imaging; Cardiac pacemaker; Implantable cardioverter-defibrillator; Cardiac troponin; CARDIOVERTER-DEFIBRILLATORS; IN-VIVO; PERMANENT PACEMAKERS; 1.5; TESLA; SAFETY; LEADS; MRI; VITRO; ASSAY;
D O I
10.1007/s10840-015-0064-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has been safely performed in many patients with cardiac implantable electronic devices (CIEDs) using institution-specific protocols. A potential risk of MRI is myocardial heating and cardiac injury, which might be detectable with cardiac Troponin (cTn). We evaluated this in patients with CIEDs undergoing MRI. Prospective data were collected from 2008 to the present in patients with CIEDs undergoing clinically indicated MRI performed under institutional protocol. Cardiac Troponin T (cTnT) levels were drawn both before and 24-36 h after the procedure. The collective data were retrospectively analyzed. MRI exams (n = 512) were performed in 398 patients. Of these, there were 348 unique scans with cTnT recorded before and after MRI (median age 68, IQ 56-78; 62 % men). cTnT did not significantly change for the group as a whole (0.00 +/- 0.056). There were 22 (6.3 %) exams with cTnT change a parts per thousand yen0.002 ng/mL following MRI (range 0.01-0.09 ng/mL). There were no clinically significant events in these patients directly attributable to MR. There were no significant changes in pacing threshold or impedance in the group with elevated cardiac biomarkers. There are very few situations where myocardial injury as detected by cTnT in patients undergoing MRI with CIEDs could be detected. No adverse clinical events or functional changes of the device were noted, even in those with increases in cTnT. Our experience supports that MRI can be performed safely for appropriately selected patients under close clinical observation. Proactive monitoring with the present iteration of cardiac biomarkers appears to be of limited utility, but prospective monitoring with high sensitivity assays may be able to detect subclinical myocardial damage.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 50 条
  • [31] A Prospective Evaluation of a Protocol for Magnetic Resonance Imaging of Patients With Implanted Cardiac Devices
    Nazarian, Saman
    Hansford, Rozann
    Roguin, Ariel
    Goldsher, Dorith
    Zviman, Menekhem M.
    Lardo, Albert C.
    Caffo, Brian S.
    Frick, Kevin D.
    Kraut, Michael A.
    Kamel, Ihab R.
    Calkins, Hugh
    Berger, Ronald D.
    Bluemke, David A.
    Halperin, Henry R.
    ANNALS OF INTERNAL MEDICINE, 2011, 155 (07) : 415 - U39
  • [32] How to perform magnetic resonance imaging on patients with implantabte cardiac arrhythmia devices
    Nazarian, Saman
    Halperin, Henry R.
    HEART RHYTHM, 2009, 6 (01) : 138 - 143
  • [33] Reducing cardiac implantable electronic device-induced artefacts in cardiac magnetic resonance imaging
    Vuorinen, Aino-Maija
    Lehmonen, Lauri
    Karvonen, Jarkko
    Holmstrom, Miia
    Kivisto, Sari
    Kaasalainen, Touko
    EUROPEAN RADIOLOGY, 2023, 33 (02) : 1229 - 1242
  • [34] Cardiac Magnetic Resonance in Patients With Cardiac Implantable Electronic Devices Challenges and Solutions
    Rajiah, Prabhakar
    Kay, Fernando
    Bolen, Michael
    Patel, Amit R.
    Landeras, Luis
    JOURNAL OF THORACIC IMAGING, 2020, 35 (01) : W1 - W17
  • [35] The use of 1.5 T magnetic resonance imaging for therapeutic decisions in patients with cardiac implantable electronic devices and significant neurological, neurosurgical and neuro-oncology diagnostic indications
    Hawryluk, Lukasz
    Sterlinski, Maciej
    Marczak, Magdalena
    Misko, Jolanta
    Podgorski, Jan Krzysztof
    Szwed, Hanna
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2015, 49 (01) : 16 - 23
  • [36] MRI of Patients with Cardiac Implantable Electronic Devices
    Martinez, Jessica A.
    Ennis, Daniel B.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (07)
  • [37] MRI in patients with cardiac implantable electronic devices: A comprehensive review
    Deshpande, Saurabh
    Kella, Danesh
    Padmanabhan, Deepak
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (02): : 360 - 372
  • [38] Consensus document on magnetic resonance imaging in patients with cardiac implanted electronic devices
    Almeida, Ana G.
    Antonio, Natalia
    Saraiva, Carla
    Ferreira, Antonio Miguel
    Reis, Antonio Hipolito
    Marques, Hugo
    Ferreira, Nuno Dias
    Oliveira, Mario
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (01) : 41 - 52
  • [39] Multicenter retrospective evaluation of magnetic resonance imaging in pediatric and congenital heart disease patients with cardiac implantable electronic devices
    Gakenheimer-Smith, Lindsey
    Ou, Zhining
    Kuang, Jinqiu
    Moore, Jeremy P.
    Burrows, Austin
    Kovach, Joshua
    Dechert, Brynn
    Beach, Cheyenne M.
    Ayers, Mark
    Tan, Reina Bianca
    Mostafavifar, Mina
    Mah, Douglas Y.
    Conner, Tracy Marrs
    Turpin, Susan
    Avasarala, Kishor
    Shah, Maully J.
    Webster, Gregory
    Posey, Jessica
    Etheridge, Susan P.
    Binka, Edem
    Niu, Mary
    Asaki, S. Yukiko
    Lambert, Linda M.
    Pilcher, Thomas A.
    HEART RHYTHM, 2023, 20 (12) : 1752 - 1758
  • [40] Cardiac magnetic resonance imaging using wideband sequences in patients with nonconditional cardiac implanted electronic devices
    Do, Duc H.
    Eyvazian, Vaughn
    Bayoneta, Aileen J.
    Hu, Peng
    Finn, J. Paul
    Bradfield, Jason S.
    Shivkumar, Kalyanam
    Boyle, Noel G.
    HEART RHYTHM, 2018, 15 (02) : 218 - 225