Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging

被引:7
|
作者
Higgins, John V. [1 ]
Watson, Robert E., Jr. [4 ]
Jaffe, Allan S. [3 ]
Dalzell, Connie [2 ]
Acker, Nancy [2 ]
Felmlee, Joel P. [4 ]
Asirvatham, Samuel J. [2 ]
Cha, Yong-Mei [2 ]
Friedman, Paul A. [2 ]
Kapa, Suraj [2 ,5 ]
机构
[1] Univ Nebraska Med Ctr, Cardiovasc Dis, Omaha, NE USA
[2] Mayo Clin, Heart Rhythm Serv, Rochester, MN 55905 USA
[3] Mayo Clin, Cardiovasc Dis, Rochester, MN 55905 USA
[4] Mayo Clin, Radiol, Rochester, MN 55905 USA
[5] Mayo Clin, Div Cardiovasc Dis, 200 First St SW, Rochester, MN 55905 USA
关键词
Magnetic resonance imaging; Cardiac pacemaker; Implantable cardioverter-defibrillator; Cardiac troponin; CARDIOVERTER-DEFIBRILLATORS; IN-VIVO; PERMANENT PACEMAKERS; 1.5; TESLA; SAFETY; LEADS; MRI; VITRO; ASSAY;
D O I
10.1007/s10840-015-0064-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has been safely performed in many patients with cardiac implantable electronic devices (CIEDs) using institution-specific protocols. A potential risk of MRI is myocardial heating and cardiac injury, which might be detectable with cardiac Troponin (cTn). We evaluated this in patients with CIEDs undergoing MRI. Prospective data were collected from 2008 to the present in patients with CIEDs undergoing clinically indicated MRI performed under institutional protocol. Cardiac Troponin T (cTnT) levels were drawn both before and 24-36 h after the procedure. The collective data were retrospectively analyzed. MRI exams (n = 512) were performed in 398 patients. Of these, there were 348 unique scans with cTnT recorded before and after MRI (median age 68, IQ 56-78; 62 % men). cTnT did not significantly change for the group as a whole (0.00 +/- 0.056). There were 22 (6.3 %) exams with cTnT change a parts per thousand yen0.002 ng/mL following MRI (range 0.01-0.09 ng/mL). There were no clinically significant events in these patients directly attributable to MR. There were no significant changes in pacing threshold or impedance in the group with elevated cardiac biomarkers. There are very few situations where myocardial injury as detected by cTnT in patients undergoing MRI with CIEDs could be detected. No adverse clinical events or functional changes of the device were noted, even in those with increases in cTnT. Our experience supports that MRI can be performed safely for appropriately selected patients under close clinical observation. Proactive monitoring with the present iteration of cardiac biomarkers appears to be of limited utility, but prospective monitoring with high sensitivity assays may be able to detect subclinical myocardial damage.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 50 条
  • [11] Magnetic resonance imaging in patients with cardiac implantable electronic devices: the RESONANCE Spanish registry
    Ruiz Mateas, Francisco
    Perez, Marcos Antonio
    Garcia Lopez, Fernando
    Gonzalez, Susana
    Anguera Camos, Ignasi
    Gusi Tragant, Gabriel
    Robledo Irranitu, Maria
    Fernandez Lozano, Ignacio
    Martinez, Juan Gabriel
    Alzueta Rodriguez, Francisco Javier
    EUROPACE, 2024, 26 (11):
  • [12] Cardiac magnetic resonance imaging at 1.5 T in patients with cardiac rhythm devices
    Buendia, Francisco
    Cano, Oscar
    Miguel Sanchez-Gomez, Juan
    Igual, Begona
    Osca, Joaquin
    Jose Sancho-Tello, Maria
    Olaguee, Jose
    Salvador, Antonio
    EUROPACE, 2011, 13 (04): : 533 - 538
  • [13] Magnetic resonance imaging in patients with cardiac implantable electronic devices: a single-center prospective study
    Yadava, Mrinal
    Nugent, Matthew
    Krebsbach, Angela
    Minnier, Jessica
    Jessel, Peter
    Henrikson, Charles A.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 50 (01) : 95 - 104
  • [14] Is diversity harmful?-Mixed-brand cardiac implantable electronic devices undergoing magnetic resonance imaging
    Koenig, Christoph Alexander
    Tinhofer, Florian
    Puntus, Thomas
    Burger, Achim Leo
    Neubauer, Nikolaus
    Langenberger, Herbert
    Huber, Kurt
    Nuernberg, Michael
    Zweiker, David
    WIENER KLINISCHE WOCHENSCHRIFT, 2022, 134 (7-8) : 286 - 293
  • [15] Magnetic resonance imaging in patients with cardiac implanted electronic devices: focus on contraindications to magnetic resonance imaging protocols
    Horwood, Laura
    Attili, Anil
    Luba, Frank
    Ibrahim, El-Sayed H.
    Parmar, Hemant
    Stojanovska, Jadranka
    Gadoth-Goodman, Sharon
    Fette, Carey
    Oral, Hakan
    Bogun, Frank
    EUROPACE, 2017, 19 (05): : 812 - 817
  • [16] Clinical Performance of Magnetic Resonance Imaging Conditional and Nonconditional Cardiac Implantable Electronic Devices
    Shah, Anand D.
    Patel, Adarsh U.
    Knezevic, Andrea
    Hoskins, Michael H.
    Hirsh, David S.
    Merchant, Faisal M.
    El Chami, Mikhael F.
    Delurgio, David B.
    Patel, Anshul M.
    Leon, Angel R.
    Langberg, Jonathan J.
    Lloyd, Michael S.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (05): : 467 - 475
  • [17] Safety of Magnetic Resonance Imaging in Patients with Cardiac Implantable Electronic Devices
    Lanz, Hugo
    Strauss, Katharina
    Hoepler, Julia
    Kraft, Marie
    Hoffmann, Sabine
    Binzenhoefer, Leonhard
    Gade, Nils
    Roden, Daniel
    Saleh, Inas
    Kaeaeb, Stefan
    Lackermair, Korbinian
    Sadoni, Sebastian
    Hagl, Christian
    Massberg, Steffen
    Estner, Heidi
    Fichtner, Stephanie
    Luesebrink, Enzo
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (10)
  • [18] Remote programming of cardiac implantable electronic devices: A novel approach to program cardiac devices for magnetic resonance imaging
    Siddamsetti, Sisir
    Shinn, Alexander
    Gautam, Sandeep
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (05) : 1005 - 1009
  • [19] Performing Cardiac Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices: A Contemporary Review
    Blissett, Sarah
    Chetrit, Michael
    Kovacina, Bojan
    Mardigyan, Vartan
    Afilalo, Jonathan
    CANADIAN JOURNAL OF CARDIOLOGY, 2018, 34 (12) : 1682 - 1686
  • [20] 3 Tesla magnetic resonance imaging in patients with cardiac implantable electronic devices: a single centre experience
    Fluschnik, Nina
    Tahir, Enver
    Erley, Jennifer
    Muellerleile, Kai
    Metzner, Andreas
    Wenzel, Jan-Per
    Guerreiro, Helena
    Adam, Gerhard
    Blankenberg, Stefan
    Kirchhof, Paulus
    Toennis, Tobias
    Nikorowitsch, Julius
    EUROPACE, 2023, 25 (02): : 571 - 577