Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging

被引:7
作者
Higgins, John V. [1 ]
Watson, Robert E., Jr. [4 ]
Jaffe, Allan S. [3 ]
Dalzell, Connie [2 ]
Acker, Nancy [2 ]
Felmlee, Joel P. [4 ]
Asirvatham, Samuel J. [2 ]
Cha, Yong-Mei [2 ]
Friedman, Paul A. [2 ]
Kapa, Suraj [2 ,5 ]
机构
[1] Univ Nebraska Med Ctr, Cardiovasc Dis, Omaha, NE USA
[2] Mayo Clin, Heart Rhythm Serv, Rochester, MN 55905 USA
[3] Mayo Clin, Cardiovasc Dis, Rochester, MN 55905 USA
[4] Mayo Clin, Radiol, Rochester, MN 55905 USA
[5] Mayo Clin, Div Cardiovasc Dis, 200 First St SW, Rochester, MN 55905 USA
关键词
Magnetic resonance imaging; Cardiac pacemaker; Implantable cardioverter-defibrillator; Cardiac troponin; CARDIOVERTER-DEFIBRILLATORS; IN-VIVO; PERMANENT PACEMAKERS; 1.5; TESLA; SAFETY; LEADS; MRI; VITRO; ASSAY;
D O I
10.1007/s10840-015-0064-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has been safely performed in many patients with cardiac implantable electronic devices (CIEDs) using institution-specific protocols. A potential risk of MRI is myocardial heating and cardiac injury, which might be detectable with cardiac Troponin (cTn). We evaluated this in patients with CIEDs undergoing MRI. Prospective data were collected from 2008 to the present in patients with CIEDs undergoing clinically indicated MRI performed under institutional protocol. Cardiac Troponin T (cTnT) levels were drawn both before and 24-36 h after the procedure. The collective data were retrospectively analyzed. MRI exams (n = 512) were performed in 398 patients. Of these, there were 348 unique scans with cTnT recorded before and after MRI (median age 68, IQ 56-78; 62 % men). cTnT did not significantly change for the group as a whole (0.00 +/- 0.056). There were 22 (6.3 %) exams with cTnT change a parts per thousand yen0.002 ng/mL following MRI (range 0.01-0.09 ng/mL). There were no clinically significant events in these patients directly attributable to MR. There were no significant changes in pacing threshold or impedance in the group with elevated cardiac biomarkers. There are very few situations where myocardial injury as detected by cTnT in patients undergoing MRI with CIEDs could be detected. No adverse clinical events or functional changes of the device were noted, even in those with increases in cTnT. Our experience supports that MRI can be performed safely for appropriately selected patients under close clinical observation. Proactive monitoring with the present iteration of cardiac biomarkers appears to be of limited utility, but prospective monitoring with high sensitivity assays may be able to detect subclinical myocardial damage.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 25 条
[1]   Effects of magnetic resonance Imaging on cardiac pacemakers and electrodes [J].
Achenbach, S ;
Moshage, W ;
Diem, B ;
Bieberle, T ;
Schibgilla, V ;
Bachmann, K .
AMERICAN HEART JOURNAL, 1997, 134 (03) :467-473
[2]   Troponin: the biomarker of choice for the detection of cardiac injury [J].
Babuin, L ;
Jaffe, AS .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2005, 173 (10) :1191-1202
[3]   Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach [J].
Boilson, Barry Anthony ;
Wokhlu, Anita ;
Acker, Nancy G. ;
Felmlee, Joel P. ;
Watson, Robert E., Jr. ;
Julsrud, Paul R. ;
Friedman, Paul A. ;
Cha, Yong-Mei ;
Rea, Robert F. ;
Hayes, David L. ;
Shen, Win-Kuang .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 33 (01) :59-67
[4]   Magnetic Resonance Imaging in Patients with Recently Implanted Pacemakers [J].
Friedman, Hannah L. ;
Acker, Nancy ;
Dalzell, Connie ;
Shen, Win K. ;
Asirvatham, Samuel J. ;
Cha, Yong-Mei ;
Hodge, David ;
Felmlee, Joel ;
Watson, Robert ;
Friedman, Paul A. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (09) :1090-1095
[5]   Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay [J].
Giannitsis, Evangelos ;
Kurz, Kerstin ;
Hallermayer, Klaus ;
Jarausch, Jochen ;
Jaffe, Allan S. ;
Katus, Hugo A. .
CLINICAL CHEMISTRY, 2010, 56 (02) :254-261
[6]   "Power-on resets" in cardiac implantable electronic devices during magnetic resonance imaging [J].
Higgins, John V. ;
Sheldon, Seth H. ;
Watson, Robert E., Jr. ;
Dalzell, Connie ;
Acker, Nancy ;
Cha, Yong-Mei ;
Asirvatham, Samuel J. ;
Kapa, Suraj ;
Felmlee, Joel P. ;
Friedman, Paul A. .
HEART RHYTHM, 2015, 12 (03) :540-544
[7]   Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads [J].
Higgins, John V. ;
Gard, Joseph J. ;
Sheldon, Seth H. ;
Espinosa, Raul E. ;
Wood, Christopher P. ;
Felmlee, Joel P. ;
Cha, Yong-Mei ;
Asirvatham, Samuel J. ;
Dalzell, Connie ;
Acker, Nancy ;
Watson, Robert E., Jr. ;
Friedman, Paul A. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (10) :1284-1290
[8]   Safe magnetic resonance image scanning of the pacemaker patient: current technologies and future directions [J].
Jung, Werner ;
Zvereva, Vlada ;
Hajredini, Bajram ;
Jaeckle, Sebastian .
EUROPACE, 2012, 14 (05) :631-637
[9]   Current clinical issues for MRI scanning of pacemaker and defibrillator patients [J].
Kalin, R ;
Stanton, MS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (04) :326-328
[10]   Pacemaker Lead Tip Heating in Abandoned and Pacemaker-Attached Leads at 1.5 Tesla MRI [J].
Langman, Deborah A. ;
Goldberg, Ira B. ;
Finn, J. Paul ;
Ennis, Daniel B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (02) :426-431