A simple and efficient UV irradiator specifically designed for dose reassessment by phototransferred thermo-luminescence is described. The instrument permits the automatic irradiation of loose TLD chips for a preselected time and at a controlled temperature. The good phototransference characteristics allow the efficient reassessment of absorbed doses of the order of 0.2 mGy with good measurement performance, well within the limits required for personnel dosimetry.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 50 条
  • [21] REINVESTIGATION OF THE SENSITIZATION MECHANISM IN LIF TLD-100 PHOSPHOR
    LAKSHMANAN, AR
    BHATT, RC
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1980, 57 (01): : 323 - 329
  • [22] Study of TLD-100's Repeatability in Low Dose Irradiation
    Akter, Yasmin
    Rahman, A. K. M. Mizanur
    Sahadath, Md. Hossain
    2018 INTERNATIONAL CONFERENCE ON INNOVATION IN ENGINEERING AND TECHNOLOGY (ICIET), 2018,
  • [23] ANALYSIS OF THERMOLUMINESCENT GLOW PEAKS IN LIF (TLD-100)
    TAYLOR, GC
    LILLEY, E
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1978, 11 (04) : 567 - 581
  • [24] TRAPPING PARAMETERS FOR PEAK XII IN LIF TLD-100
    KATHURIA, SP
    MOHARIL, SV
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1983, 16 (10) : 2011 - 2016
  • [25] THERMOLUMINESCENCE SPECTRUM OF HEAVILY IRRADIATED LIF(TLD-100)
    JAIN, VK
    BAPAT, VN
    KATHURIA, SP
    JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1973, 6 (17): : L343 - L344
  • [26] TRAPPING PARAMETERS FOR PEAK IV IN LIF TLD-100
    KATHURIA, SP
    MOHARIL, SV
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1983, 16 (07) : 1331 - 1341
  • [27] THERMAL QUENCHING BY PHOTOTRANSFER IN LIF TLD-100 - REPLY
    KATHURIA, SP
    SUNTA, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (04): : 604 - 605
  • [28] THERMAL QUENCHING BY PHOTOTRANSFER IN LIF TLD-100 - COMMENT
    HOROWITZ, YS
    PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (04): : 603 - 604
  • [29] ON THE PECULIARITIES OF PEAK-4 IN LIF TLD-100
    DELGADO, A
    MUNIZ, JL
    ROS, JMG
    RADIATION MEASUREMENTS, 1994, 23 (04) : 693 - 701
  • [30] Dose response of F center optical absorption in LiF:Mg,Ti (TLD-100)
    Biderman, S.
    Eliyahu, I.
    Horowitz, Y. S.
    Oster, L.
    RADIATION MEASUREMENTS, 2014, 71 : 237 - 241