His-Bundle Pacing for Identifying Optimal Ablation Sites in Patients Undergoing Atrioventricular Junction Ablation

被引:1
|
作者
Kulkarni, Nitin [1 ]
Moore, Curtiss [1 ]
Pandey, Ambarish [1 ]
Castillo, Demetrio [1 ]
Ayers, Colby [1 ,2 ]
Joglar, Jose [1 ]
Wu, Richard [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Div Cardiol, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Clin Sci, Dallas, TX 75390 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2017年 / 40卷 / 03期
关键词
atrial fibrillation; AVJ junction ablation; AVN node ablation; his-bundle pacing; CARDIAC RESYNCHRONIZATION; ATRIAL;
D O I
10.1111/pace.13019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrioventricular (AV) junction (AVJ) ablation is conventionally performed by localizing the His-bundle electrogram (HBE). Identification of HBE in the presence of atrial fibrillation (AF) can be difficult, and can make this simple procedure challenging. In this study, we describe our experience with an alternative approach to localize optimal ablation sites using His-bundle pacing (HBP). Methods: Between 1/1/2014 and 12/31/2015, we performed 13 AVJ ablations using the standard electrogram-guided approach and 11 ablations using HBP. All cases utilized a long femoral guiding sheath and an 8-mm-tip electrode radiofrequency (RF) energy ablation catheter. Pacing was performed at high output (10 mA at 2 ms) to initially achieve right bundle branch capture. The catheter was withdrawn until a narrow QRS morphology and increased stim-to-QRS time were observed. HBP was confirmed when paced and native QRS were identical in morphology. RF energy was applied at the site of HBP capture until AV block was observed. Results: Baseline characteristics of patients in each arm were not significantly different. Compared with the standard approach, HBP was associated with trends toward lower RF applications (3 vs. 2, P = 0.16) and shorter mean RF time (208 seconds vs. 128 seconds, P = 0.19). Conclusion: HBP is an effective technique to identify optimal ablation sites during AVJ ablation and may shorten procedure time. HBP can be used to identify the AV node during AF without recording the His potential. Future studies with larger sample size are needed to better characterize the utility of this technique. (PACE 2017; 40: 242-246)
引用
收藏
页码:242 / 246
页数:5
相关论文
共 50 条
  • [31] HIGH-ENERGY HIS-BUNDLE ABLATION - A TREATMENT OF LAST RESORT
    CAMM, AJ
    SNEDDON, JF
    CIRCULATION, 1991, 84 (05) : 2187 - 2189
  • [32] What Is the Threshold for Dyssynchrony in Patients Undergoing Atrioventricular Junction Ablation for Atrial Fibrillation?
    Cronin, Edmond M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (10):
  • [33] Honing in on Optimal Ventricular Pacing Sites: an Argument for His Bundle Pacing
    Lee M.Y.
    Yeshwant S.C.
    Lustgarten D.L.
    Current Treatment Options in Cardiovascular Medicine, 2015, 17 (4)
  • [34] His-bundle and left bundle pacing with optimized atrioventricular delay achieve superior electrical synchrony over endocardial and epicardial pacing in left bundle branch block patients
    Strocchi, Marina
    Lee, Angela W. C.
    Neic, Aurel
    Bouyssier, Julien
    Gillette, Karli
    Plank, Gernot
    Elliott, Mark K.
    Gould, Justin
    Behar, Jonathan M.
    Sidhu, Baldeep
    Mehta, Vishal
    Bishop, Martin J.
    Vigmond, Edward J.
    Rinaldi, Christopher A.
    Niederer, Steven A.
    HEART RHYTHM, 2020, 17 (11) : 1922 - 1929
  • [35] Impact of QRS morphology on response to conduction system pacing after atrioventricular junction ablation
    Wu, Shengjie
    Cai, Mengxing
    Zheng, Rujie
    Wang, Songjie
    Jiang, Limeng
    Xu, Lei
    Shi, Ruiyu
    Xiao, Fangyi
    Ellenbogen, Kenneth A.
    Cha, Yongmei
    Su, Lan
    Huang, Weijian
    ESC HEART FAILURE, 2021, 8 (02): : 1195 - 1203
  • [36] Cardiac resynchronization therapy in patients undergoing atrioventricular junction ablation for permanent atrial fibrillation: a randomized trial
    Brignole, Michele
    Botto, Gianluca
    Mont, Lluis
    Iacopino, Saverio
    De Marchi, Giuseppe
    Oddone, Daniele
    Luzi, Mario
    Tolosana, Jose M.
    Navazio, Alessandro
    Menozzi, Carlo
    EUROPEAN HEART JOURNAL, 2011, 32 (19) : 2420 - 2429
  • [37] HIS-BUNDLE ABLATION FOR SUPRAVENTRICULAR ARRHYTHMIAS TO AVOID SPURIOUS SHOCKS OF AN IMPLANTED DEFIBRILLATOR
    JORDAENS, L
    CAENEPEEL, A
    CALLE, P
    CLINICAL CARDIOLOGY, 1992, 15 (09) : 693 - 695
  • [38] Should all patients undergoing atrioventricular junction ablation receive cardiac resynchronization therapy?
    Jensen-Urstad, Mats
    EUROPACE, 2012, 14 (10): : 1383 - 1384
  • [39] Case report: Treatment of tachycardia-induced cardiogenic shock with permanent His bundle pacing and atrioventricular node ablation
    Zlahtic, Tadej
    Fister, Misa
    Radsel, Peter
    Noc, Marko
    Sinkovec, Matjaz
    Zizek, David
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [40] A review on atrioventricular junction ablation and pacing for heart rate control of atrial fibrillation
    Vlachos, Konstantinos
    Letsas, Konstantinos P.
    Korantzopoulos, Panagiotis
    Liu, Tong
    Efremidis, Michael
    Sideris, Antonios