His-Bundle Pacing for Identifying Optimal Ablation Sites in Patients Undergoing Atrioventricular Junction Ablation

被引:1
|
作者
Kulkarni, Nitin [1 ]
Moore, Curtiss [1 ]
Pandey, Ambarish [1 ]
Castillo, Demetrio [1 ]
Ayers, Colby [1 ,2 ]
Joglar, Jose [1 ]
Wu, Richard [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Div Cardiol, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Clin Sci, Dallas, TX 75390 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2017年 / 40卷 / 03期
关键词
atrial fibrillation; AVJ junction ablation; AVN node ablation; his-bundle pacing; CARDIAC RESYNCHRONIZATION; ATRIAL;
D O I
10.1111/pace.13019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrioventricular (AV) junction (AVJ) ablation is conventionally performed by localizing the His-bundle electrogram (HBE). Identification of HBE in the presence of atrial fibrillation (AF) can be difficult, and can make this simple procedure challenging. In this study, we describe our experience with an alternative approach to localize optimal ablation sites using His-bundle pacing (HBP). Methods: Between 1/1/2014 and 12/31/2015, we performed 13 AVJ ablations using the standard electrogram-guided approach and 11 ablations using HBP. All cases utilized a long femoral guiding sheath and an 8-mm-tip electrode radiofrequency (RF) energy ablation catheter. Pacing was performed at high output (10 mA at 2 ms) to initially achieve right bundle branch capture. The catheter was withdrawn until a narrow QRS morphology and increased stim-to-QRS time were observed. HBP was confirmed when paced and native QRS were identical in morphology. RF energy was applied at the site of HBP capture until AV block was observed. Results: Baseline characteristics of patients in each arm were not significantly different. Compared with the standard approach, HBP was associated with trends toward lower RF applications (3 vs. 2, P = 0.16) and shorter mean RF time (208 seconds vs. 128 seconds, P = 0.19). Conclusion: HBP is an effective technique to identify optimal ablation sites during AVJ ablation and may shorten procedure time. HBP can be used to identify the AV node during AF without recording the His potential. Future studies with larger sample size are needed to better characterize the utility of this technique. (PACE 2017; 40: 242-246)
引用
收藏
页码:242 / 246
页数:5
相关论文
共 50 条
  • [21] Feasibility and Efficacy of His Bundle Pacing or Left Bundle Pacing Combined With Atrioventricular Node Ablation in Patients With Persistent Atrial Fibrillation and Implantable Cardioverter-Defibrillator Therapy
    Wang, Songjie
    Wu, Shengjie
    Xu, Lei
    Xiao, Fangyi
    Whinnett, Zachary I.
    Vijayaraman, Pugazhendhi
    Su, Lan
    Huang, Weijian
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (24):
  • [22] His-bundle pacing vs biventricular pacing following atrioventricular nodal ablation in patients with atrial fibrillation and reduced ejection fraction: A multicenter, randomized, crossover study-The ALTERNATIVE-AF trial
    Huang, Weijian
    Wang, Songjie
    Su, Lan
    Fu, Guosheng
    Su, Yangang
    Chen, Keping
    Zou, Jiangang
    Han, Hongwei
    Wu, Shengjie
    Sheng, Xia
    Chen, Xueying
    Fan, Xiaohan
    Xu, Lei
    Zhou, Xiaohong
    Mao, Guangyun
    Ellenbogen, Kenneth A.
    Whinnett, Zachary, I
    HEART RHYTHM, 2022, 19 (12) : 1948 - 1955
  • [23] Permanent His-bundle pacing in patients with prosthetic cardiac valves
    Sharma, Parikshit S.
    Subzposh, Faiz A.
    Ellenbogen, Kenneth A.
    Vijayaraman, Pugazhendhi
    HEART RHYTHM, 2017, 14 (01) : 59 - 64
  • [24] Left bundle branch area pacing prevails over His bundle pacing for heart failure patients undergoing atrioventricular node ablation in permanent atrial fibrillation: a network meta-analysis
    Ding, Jing-Wen
    Jiang, Yu-Ang
    Wang, Qiu-Ting
    Yao, Jian-hui
    Dai, Gong-Qiang
    Ding, Huai-Sheng
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2025,
  • [25] "Ablate and Pace" with Conduction System Pacing: Concomitant versus Delayed Atrioventricular Junction Ablation
    Palmisano, Pietro
    Ziacchi, Matteo
    Dell'Era, Gabriele
    Donateo, Paolo
    Bartoli, Lorenzo
    Patti, Giuseppe
    Senes, Jacopo
    Parlavecchio, Antonio
    Biffi, Mauro
    Accogli, Michele
    Coluccia, Giovanni
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [26] Direct His Bundle Pacing Post AVN Ablation
    Lakshmanadoss, Umashankar
    Aggarwal, Ashim
    Huang, David T.
    Daubert, James P.
    Shah, Abrar
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (08): : 1101 - 1104
  • [27] Effectiveness and safety of AV node ablation after His bundle pacing in patients with uncontrolled atrial arrhythmias
    Morina-Vazquez, Pablo
    Teresa Moraleda-Salas, Maria
    Arce-Leon, Alvaro
    Venegas-Gamero, Jose
    Manuel Fernandez-Gomez, Juan
    Francisco Diaz-Fernandez, Jose
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (06): : 1004 - 1009
  • [28] High efficiency and workflow of His bundle pacing and atrioventricular node ablation guided by three-dimensional mapping system
    Sun, Yuanjun
    Yu, Xiaohong
    Xiao, Xianjie
    Yin, Xiaomeng
    Gao, Lianjun
    Zhang, Rongfeng
    Dai, Shiyu
    Wang, Nan
    Zhang, Duoduo
    Dong, Yingxue
    Yang, Yanzong
    Xia, Yunlong
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (10): : 1165 - 1172
  • [29] Permanent His bundle pacing and atrioventricular node ablation in a case with drug-refractory atrial fibrillation
    Saygi, Serkan
    Erturk, Emre
    Topaloglu, Caner
    Abusharekh, Mohammed
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2019, 47 (08): : 691 - 694
  • [30] A Case Report of a Wenckebach Phenomenon Occurring during a His-Bundle Pacing Procedure: Is It Atrioventricular Node Pacing?
    Ma, Chengming
    Li, Wenwen
    Cha, Yongmei
    Xia, Yunlong
    Gao, Lianjun
    Dong, Yingxue
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (07)