Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout

被引:110
作者
Huppertz, Alexander [1 ,2 ]
Hermann, Kay-Geert A. [1 ]
Diekhoff, Torsten [1 ]
Wagner, Moritz [1 ]
Hamm, Bernd [1 ,2 ]
Schmidt, Wolfgang A. [3 ]
机构
[1] Charite, Dept Radiol, D-10117 Berlin, Germany
[2] Imaging Sci Inst Charite, D-10115 Berlin, Germany
[3] Immanuel Krankenhaus Berlin Buch, Med Ctr Rheumatol, D-13125 Berlin, Germany
关键词
Gout; Crystal deposition arthropathy; Dual-energy computed tomography; Ultrasonography; Polarisation microscopy; URIC-ACID; DIAGNOSIS; ULTRASONOGRAPHY; DISEASE; ARTHRITIS; INSIGHTS; JOINT; HYPERURICEMIA; INVOLVEMENT; MANAGEMENT;
D O I
10.1007/s00296-014-2979-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective of the study is to compare the diagnostic accuracy for detecting monosodium urate crystal deposits between dual-energy CT (DECT) and ultrasound (US). Sixty consecutive patients (49 men, mean age 62 years) with clinically suspected gout were included in this case-control study. DECT and US of feet, knees, hands and elbows were performed in all patients. Polarisation microscopy of synovial fluid or a score incorporating serum uric acid level, first MTP joint involvement, gender, previous patient-reported arthritis attack, cardiovascular diseases, joint redness and onset within 1 day was used as standard of reference. Standard of reference classified 39 patients as gout positive. Sixteen patients had gout and a concomitant rheumatic disease. Sensitivities for diagnosis of gout disease were 84.6 % (33/39) for DECT and 100 % (39/39) for US. Specificities were 85.7 % (18/21) for DECT and 76.2 % (16/21) for US. Positive and negative predictive values were 91.7 % (33/36) and 75.0 % (18/24) for DECT, 88.6 % (39/44) and 100 % (16/16) for US, respectively. Urate crystals were detected most frequently in MTP1 joints (DECT 20/78, US 58/78), any other toe joints (DECT 25/78, US 62/78) and knees (DECT 41/78, US 31/78). The volumetry of DECT computed a mean urate crystal deposit load of 2.1 cm(3) (SD 9.6 cm(3)). A mean effective dose of a parts per thousand currency sign0.5 mSv was estimated. DECT is more specific for the diagnosis of gout than US. However, it fails to detect small urate crystal deposits. It might be particularly useful for patients with ambivalent findings, concomitant rheumatic diseases and with non-conclusive joint aspiration.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 31 条
  • [1] Dual energy computed tomography in tophaceous gout
    Choi, H. K.
    Al-Arfaj, A. M.
    Eftekhari, A.
    Munk, P. L.
    Shojania, K.
    Reid, G.
    Nicolaou, S.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) : 1609 - 1612
  • [2] Dual energy CT in gout: a prospective validation study
    Choi, Hyon K.
    Burns, Lindsay C.
    Shojania, Kamran
    Koenig, Nicole
    Reid, Graham
    Abufayyah, Mohammed
    Law, Genevieve
    Kydd, Alison S.
    Ouellette, Hugue
    Nicolaou, Savvas
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2012, 71 (09) : 1466 - 1471
  • [3] A systematic review of ultrasonography in gout and asymptomatic hyperuricaemia
    Chowalloor, Priya V.
    Keen, Helen Isobel
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2013, 72 (05) : 638 - 645
  • [4] New Therapies for Gout
    Crittenden, Daria B.
    Pillinger, Michael H.
    [J]. ANNUAL REVIEW OF MEDICINE, VOL 64, 2013, 64 : 325 - 337
  • [5] Tendon involvement in the feet of patients with gout: a dual-energy CT study
    Dalbeth, Nicola
    Kalluru, Ramanamma
    Aati, Opetaia
    Horne, Anne
    Doyle, Anthony J.
    McQueen, Fiona M.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2013, 72 (09) : 1545 - 1548
  • [6] Imaging in gout: insights into the pathological features of disease
    Dalbeth, Nicola
    Doyle, Anthony
    McQueen, Fiona M.
    [J]. CURRENT OPINION IN RHEUMATOLOGY, 2012, 24 (02) : 132 - 138
  • [7] Methods of tophus assessment in clinical trials of chronic gout: a systematic literature review and pictorial reference guide
    Dalbeth, Nicola
    Schauer, Cameron
    MacDonald, Patricia
    Perez-Ruiz, Fernando
    Schumacher, H. Ralph
    Hamburger, Steve
    Choi, Hyon K.
    McQueen, Fiona M.
    Doyle, Anthony
    Taylor, William J.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2011, 70 (04) : 597 - 604
  • [8] Clinical Utility of Dual-Energy CT for Evaluation of Tophaceous Gout
    Desai, Madhura A.
    Peterson, Jeffrey J.
    Garner, Hillary Warren
    Kransdorf, Mark J.
    [J]. RADIOGRAPHICS, 2011, 31 (05) : 1365 - 1375
  • [9] Uric acid and cardiovascular risk
    Feig, Daniel I.
    Kang, Duk-Hee
    Johnson, Richard J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (17) : 1811 - 1821
  • [10] Hyaline cartilage involvement in patients with gout and calcium pyrophosphate deposition disease. An ultrasound study
    Filippucci, E.
    Riveros, M. Gutierrez
    Georgescu, D.
    Salaffi, F.
    Grassi, W.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (02) : 178 - 181