Application of real-time shear wave elastography in the assessment of torsional cervical dystonia

被引:8
作者
Song, Ye [1 ]
Zhang, Tian-Jie [2 ]
Li, Yuan [1 ]
Gao, Yuan [3 ]
机构
[1] Shanghai Univ Med & Hlth Sci, Coll Med Imaging, Zhoupu Hosp, Dept Ultrasonog, Shanghai 201318, Peoples R China
[2] Shanghai Huapukang Pediat Clin, Shanghai 310105, Peoples R China
[3] Tongji Univ, Dept Surg, Tongji Hosp, Shanghai 200065, Peoples R China
关键词
Shear wave elastography; real-time; torsional cervical dystonia; skeletal muscle; shear elastic modulus; PASSIVE MUSCLE-STIFFNESS; QUANTITATIVE ASSESSMENT; BOTULINUM TOXIN; RELIABILITY; CHILDREN; HARDNESS;
D O I
10.21037/qims.2019.04.08
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: This study aimed to investigate the value of real-time shear wave elastography (SWE) in the assessment of torsional cervical dystonia (TCD). Methods: Ninety healthy volunteers and 30 TCD patients were recruited, and elastography was performed at musculi sternocleidomastoideus (MSD) and musculi splenius capitis (MSC). Mean shear elastic modulus of right MSD and MSC in healthy controls and bilateral MSD and MSC in TCD patients was determined. The thickness of MSD and MSC of affected muscles was measured in TCD patients. Results: In TCD patients, the mean shear elastic modulus of affected MSD and MSC was significantly higher than that of corresponding normal muscles (P<0.01) and that of controls (P<0.01). The diagnostic threshold was 24.9 kPa for MSD and 25.07 kPa for MSC (for MSD and MSC, the area under ROC was 0.979 and 0.979, with a sensitivity of 90% and 91.3%, and a specificity of 95.6% and 96.7%, respectively). The elastic modulus of neither affected nor normal MSD and MSC was significantly related to age and body mass index (P>0.05). The shear elastic modulus of affected MSD and MSC was positively related to the peak electromyography (r=0.83-0.73, P<0.01). The thickness of affected MSD and MSC was significantly thicker than that of corresponding normal muscles in TCD patients (P<0.01). Conclusions: Real-time SWE can identify the difference in shear elastic modulus of MSD and MSC between the affected and normal side in TCD patients, indicating important diagnostic value in the assessment of muscular status for these patients.
引用
收藏
页码:662 / 670
页数:9
相关论文
共 50 条
  • [31] The role of real-time shear wave elastography in the diagnosis of idiopathic nephrotic syndrome and evaluation of the curative effect
    Xue Yang
    Fang-Lin Hou
    Cheng Zhao
    Cai-Yun Jiang
    Xiu-Mei Li
    Ning Yu
    Abdominal Radiology, 2020, 45 : 2508 - 2517
  • [32] Incorporation of shear wave elastography into a prediction model in the assessment of cervical lymph nodes
    Lo, Wu-Chia
    Hsu, Wan-Lun
    Wang, Chi-Te
    Cheng, Po-Wen
    Liao, Li-Jen
    PLOS ONE, 2019, 14 (08):
  • [33] Real-time shear wave ultrasound elastography: a new tool for the evaluation of diaphragm and limb muscle stiffness in critically ill patients
    Flattres, Aurelien
    Aarab, Yassir
    Nougaret, Stephanie
    Garnier, Fanny
    Larcher, Romaric
    Amalric, Mathieu
    Klouche, Kada
    Etienne, Pascal
    Subra, Gilles
    Jaber, Samir
    Molinari, Nicolas
    Matecki, Stefan
    Jung, Boris
    CRITICAL CARE, 2020, 24 (01)
  • [34] Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study
    Shi, Li
    Li, Xiaoju
    Liao, Wei
    Wu, Wenxin
    Xu, Ming
    DIAGNOSTICS, 2023, 13 (06)
  • [35] Comparison of Two-Dimensional Shear Wave Elastography and Real-Time Tissue Elastography for Assessing Liver Fibrosis in Chronic Hepatitis B
    Wu, Tao
    Wang, Ping
    Zhang, Ting
    Zheng, Jian
    Li, Shuoyang
    Zeng, Jie
    Kudo, Masatoshi
    Zheng, Rongqin
    DIGESTIVE DISEASES, 2016, 34 (06) : 640 - 649
  • [36] Combined Assessment of 2-D Ultrasound and Real-Time Shear Wave Elastography of Low-Intensity Pulsed Ultrasound Therapy Efficacy in Rabbits with Achilles Tendinopathy
    Liu, Mengyao
    Zheng, Qian
    Zheng, Yiwen
    Yao, Yijing
    Wang, Rui
    Ta, Dean
    Jiang, Lixin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (03) : 407 - 413
  • [37] NAFLD evaluation: Which is more appropriate, multislice computed tomography or ultrasound real-time shear wave elastography?
    Lei, Pinggui
    Jiao, Jun
    Li, Hong
    Wang, Pingxian
    Duan, Qinghong
    Liu, Jing
    Zhou, Shi
    Wei, Qian
    Wang, Xiaolin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (05) : 871 - 883
  • [38] NORMAL LIVER STIFFNESS IN HEALTHY ADULTS ASSESSED BY REAL-TIME SHEAR WAVE ELASTOGRAPHY AND FACTORS THAT INFLUENCE THIS METHOD
    Huang, Zeping
    Zheng, Jian
    Zeng, Jie
    Wang, Xiaoli
    Wu, Tao
    Zheng, Rongqin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (11) : 2549 - 2555
  • [39] Real-time two-dimensional Shear-wave elastography for liver stiffness in children: Interobserver variation and effect of breathing technique
    Yoon, Hee Mang
    Cho, Young Ah
    Kim, Jeong Rye
    Lee, Seung Soo
    Jung, Ah Young
    Lee, Jin Seong
    Oh, Seak Hee
    Kim, Kyung Mo
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 97 : 53 - 58
  • [40] Assessment of the cervical stiffness in pregnant women using Shear Wave Elastography: a feasibility study
    Muller, M.
    Ait-Belkacem, D.
    Gennisson, J. L.
    Fink, M.
    Tanter, M.
    Hessabi, M.
    Cabrol, D.
    Tsatsaris, V.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 5 - 8