We sought to determine whether one of two prefabricated insole designs could better manage high forefoot plantar pressures in patients with rheumatoid arthritis. Ten subjects with rheumatoid arthritis who experienced pain with shod weightbearing were studied by using a plantar pressure measurement system. Two insole designs and a shoe-only control condition were randomly tested in repeated trials. Dome- and bar-shaped metatarsal pads made of latex foam were incorporated into full-length insoles made of urethane. Significant reductions in mean peak plantar pressures over the central metatarsals were noted when using the insole and dome pad design (12% [33 kPa]) and the insole and bar pad design (21% [58 kPa]) compared with the shoe-only condition. A prefabricated insole design incorporating a bar metatarsal pad is recommended to manage high forefoot plantar pressures in patients with rheumatoid arthritis.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 45 条
  • [1] Reliability of F-Scan in-shoe measurements of plantar pressure
    Ahroni, JH
    Boyko, EJ
    Forsberg, R
    [J]. FOOT & ANKLE INTERNATIONAL, 1998, 19 (10) : 668 - 673
  • [2] Barnett S, 1998, DIABETIC FOOT, V1, P137
  • [3] Barnett S, 1999, DIABET FOOT, V2, P108
  • [4] Measurement of dynamic pressures at the shoe-foot interface during normal walking with various foot orthoses using the FSCAN system
    Brown, M
    Rudicel, S
    Esquenazi, A
    [J]. FOOT & ANKLE INTERNATIONAL, 1996, 17 (03) : 152 - 156
  • [5] BURRA G, 1999, CLIN PODIATR MED SUR, V16, P363
  • [6] CAVANAGH P.R., 1992, INT J CLIN FOOT SCI, V2, P185, DOI [10.1016/0958-2592(92)90047-S, DOI 10.1016/0958-2592(92)90047-S, 10.1016/0958-2592, DOI 10.1016/0958-2592]
  • [7] Chalmers AC, 2000, J RHEUMATOL, V27, P1643
  • [8] MULTISTEP MEASUREMENT OF PLANTAR PRESSURE ALTERATIONS USING METATARSAL PADS
    CHANG, AH
    ABUFARAJ, ZU
    HARRIS, GF
    NERY, J
    SHEREFF, MJ
    [J]. FOOT & ANKLE INTERNATIONAL, 1994, 15 (12) : 654 - 660
  • [9] CORNWALL MW, 1997, FOOT, V7, P148
  • [10] CRAXFORD AD, 1982, CLIN ORTHOP RELAT R, P121