Non-invasive Blood Glucose Estimation Using Multi-sensor Based Portable and Wearable System

被引:3
作者
Mahmud, Tasfin [1 ]
Limon, Mehedi Hossen [1 ]
Ahmed, Sabbir [1 ]
Rafi, Mohammad Zunaed [1 ]
Ahamed, Borhan [1 ]
Nitol, Shadman Shahriar [1 ]
Mia, Md Yeasin [1 ]
Choudhury, Rafat Emtiaz [1 ]
Sakib, Adnan [1 ]
Subhana, Arik [1 ]
Shahnaz, Celia [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka 1205, Bangladesh
来源
2019 IEEE GLOBAL HUMANITARIAN TECHNOLOGY CONFERENCE (GHTC) | 2019年
关键词
non-invasive; blood glucose; diabetes; wearable system; convolutional neural network; multi-sensor based system; photoplethysmography;
D O I
10.1109/ghtc46095.2019.9033119
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Currently, invasive glucometers are widely used for monitoring blood glucose level. It is required to prick a finger of the subject to collect the blood sample. In this paper, a cost-effective wearable system is proposed to estimate the glucose level in a non-invasive way. Data are collected using different sensors such as photoplethysmography(PPG), galvanic skin response(GSR) and temperature sensor, and fed to a convolutional neural network (CNN) model. The model estimates the blood glucose level, which is comparable with the glucose level obtained with conventional invasive technique. This system is believed to help in monitoring blood glucose, which leads to control of diabetes and other related diseases.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 28 条
  • [1] 13. Diabetes Care in the Hospital
    不详
    [J]. DIABETES CARE, 2016, 39 : S99 - S104
  • [2] Median Based Method for Baseline Wander Removal in Photoplethysmogram Signals
    Awodeyi, Adewale Emmanuel
    Alty, Stephen R.
    Ghavami, Mohammad
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2014, : 311 - 314
  • [3] Azad S, 2017, TENCON IEEE REGION, P1, DOI 10.1109/TENCON.2017.8227826
  • [4] Boatemaa MA, 2017, ASIAN J BIOMEDICAL P, V1, P22
  • [5] Boots JMM, 2002, J AM SOC NEPHROL, V13, P221, DOI 10.1681/ASN.V131221
  • [6] Non-invasive glucose monitoring in patients with Type 1 diabetes: A Multisensor system combining sensors for dielectric and optical characterisation of skin
    Caduff, Andreas
    Talary, Mark S.
    Mueller, Martin
    Dewarrat, Francois
    Klisic, Jelena
    Donath, Marc
    Heinemann, Lutz
    Stahel, Werner A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (09) : 2778 - 2784
  • [7] Dyro J., 2014, CLIN ENG HDB
  • [8] HYPOGLYCEMIA UNAWARENESS
    GERICH, JE
    MOKAN, M
    VENEMAN, T
    KORYTKOWSKI, M
    MITRAKOU, A
    [J]. ENDOCRINE REVIEWS, 1991, 12 (04) : 356 - 371
  • [9] Hagvik J., 2007, Glucose measurement: time for a gold standard
  • [10] Humayun A., 2018, LEARNING FRONT END F, V2018, P1408