Mediastinal abscess and esophageal stricture following voice prosthesis insertion

被引:4
作者
Bozzo, Corrado [1 ]
Meloni, Francesco [3 ]
Trignano, Mario [4 ]
Profili, Stefano [2 ]
机构
[1] Osped P Dettori, UO ORL, I-07029 Tempio Pausania, Italy
[2] Osped SS Annunziata, UO Radiol, I-07100 Sassari, Italy
[3] Clin ORL Univ Sassari, I-07100 Sassari, Italy
[4] Univ Sassari, Ist Patol Chirurg, I-07100 Sassari, Italy
关键词
Voice prosthesis; Tracheo-esophageal puncture; Mediastinal abscess; Esophageal stent; TRACHEOESOPHAGEAL PUNCTURE; METAL STENT; BENIGN; REHABILITATION; COMPLICATION; LIFETIME;
D O I
10.1016/j.anl.2013.07.017
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The use of a tracheo-esophageal voice prosthesis is a well-established procedure to restore the voice in total laryngectomees. The insertion of the prosthesis is not a risk-free procedure, various complications having been reported especially in irradiated patients. Here described is a case of an esophageal rupture after secondary trachea-esophageal puncture with mediastinal abscess in a patient previously treated with pharyngo-laryngectomy and subsequent radiotherapy for a left pyriform sinus carcinoma, which required immediate surgical drainage through a left cervical approach. Few weeks after surgical drainage an esophageal stricture at the site of the rupture developed, which was only temporarily resolved after the insertion of biodegradable esophageal stents, followed by re-stenosis once the reabsorption of the stent took place. (c) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:229 / 233
页数:5
相关论文
共 17 条
[1]  
Bien Stanislaw, 2006, Otolaryngol Pol, V60, P129
[2]   The influence of radiotherapy on the lifetime of silicone rubber voice prostheses in laryngectomized patients [J].
Elving, GJ ;
van Weissenbruch, R ;
Busscher, HJ ;
van der Mei, HC ;
Albers, FWJ .
LARYNGOSCOPE, 2002, 112 (09) :1680-1683
[3]   A new and simple modification of the prosthetic voice restoration technique [J].
Görür, K ;
Özcan, C ;
Ünal, M ;
Özkul, MD .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2003, 117 (05) :365-367
[4]   Mechanical ileus caused by a Provox® voice prosthesis -: An "latrogenic" enteral complication in voice prosthesis rehabilitation of laryngectomees [J].
Hiltmann, O ;
Buntrock, M ;
Hagen, R .
LARYNGO-RHINO-OTOLOGIE, 2002, 81 (12) :890-893
[5]   A new fully covered metal stent for the treatment of benign and malignant dysphagia: a prospective follow-up study [J].
Hirdes, Meike M. C. ;
Siersema, Peter D. ;
Vleggaar, Frank P. .
GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) :712-718
[6]   TRACHEOESOPHAGEAL PUNCTURE IN IRRADIATED PATIENTS [J].
LABRUNA, A ;
KLATSKY, I ;
HUO, J ;
WEISS, MH .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1995, 104 (04) :279-281
[7]   In situ lifetime, causes for replacement, and complications of the Provox(TM) voice prosthesis [J].
Laccourreye, O ;
Menard, M ;
CrevierBuchman, L ;
Couloigner, V ;
Brasnu, D .
LARYNGOSCOPE, 1997, 107 (04) :527-530
[8]   Removable, Fully Covered, Self-expandable Metal Stents for the Treatment of Refractory Benign Esophagogastric Anastomotic Strictures [J].
Liu, Jingeng ;
Hu, Yi ;
Cui, Chengsen ;
Li, Yongfeng ;
Lin, Xiaodan ;
Fu, Jianhua .
DYSPHAGIA, 2012, 27 (02) :260-264
[9]  