Experimental Demonstration of In-Place Calibration for Time Domain Microwave Imaging System

被引:3
|
作者
Kwon, S. [1 ,2 ,3 ]
Son, S. [4 ]
Lee, K. [4 ]
机构
[1] Ewha Womans Univ, Dept Elect Engn, Seoul, South Korea
[2] Natl Canc Ctr, Ctr Specif Organs Canc, Goyang, South Korea
[3] Hanwha Syst, Team Software Radar, Yongin, Gyeonggi Do, South Korea
[4] ETRI, Radio Technol Res Dept, Daejeon, South Korea
关键词
microwave imaging; time domain measurement system; calibration; breast cancer; BREAST-CANCER DETECTION; RADAR; TISSUE;
D O I
10.1002/2017RS006399
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
In this study, the experimental demonstration of in-place calibration was conducted using the developed time domain measurement system. Experiments were conducted using three calibration methodsin-place calibration and two existing calibrations, that is, array rotation and differential calibration. The in-place calibration uses dual receivers located at an equal distance from the transmitter. The received signals at the dual receivers contain similar unwanted signals, that is, the directly received signal and antenna coupling. In contrast to the simulations, the antennas are not perfectly matched and there might be unexpected environmental errors. Thus, we experimented with the developed experimental system to demonstrate the proposed method. The possible problems with low signal-to-noise ratio and clock jitter, which may exist in time domain systems, were rectified by averaging repeatedly measured signals. The tumor was successfully detected using the three calibration methods according to the experimental results. The cross correlation was calculated using the reconstructed image of the ideal differential calibration for a quantitative comparison between the existing rotation calibration and the proposed in-place calibration. The mean value of cross correlation between the in-place calibration and ideal differential calibration was 0.80, and the mean value of cross correlation of the rotation calibration was 0.55. Furthermore, the results of simulation were compared with the experimental results to verify the in-place calibration method. A quantitative analysis was also performed, and the experimental results show a tendency similar to the simulation.
引用
收藏
页码:429 / 439
页数:11
相关论文
共 50 条
  • [41] Bi-Static Time Domain Study for Microwave Breast Imaging
    Katbay, Zahra
    Le Roy, Marc
    Olleik, Charif
    Perennec, Andre
    Sadek, Sawsan
    Lababidi, Raafat
    2018 18TH MEDITERRANEAN MICROWAVE SYMPOSIUM (MMS), 2018, : 411 - 414
  • [42] Experimental Demonstration of Statistical Stability in Ultrawideband Time-Reversal Imaging
    Fouda, Ahmed E.
    Lopez-Castellanos, V.
    Teixeira, Fernando L.
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2014, 11 (01) : 29 - 33
  • [43] Microwave Breast Imaging: Time-Domain Experiments on Tissue Phantoms
    Porter, Emily
    Santorelli, Adam
    Coates, Mark
    Popovic, Milica
    2011 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (APSURSI), 2011, : 695 - 698
  • [44] Time domain microwave imaging for a metallic cylinder by using evolutionary algorithms
    Sun, C-H
    Chiu, C-C
    Chen, C-H
    IMAGING SCIENCE JOURNAL, 2013, 61 (01): : 3 - 12
  • [45] EXPERIMENTAL DEMONSTRATION OF SWEPT-CARRIER TIME-DOMAIN OPTICAL MEMORY
    LIN, H
    WANG, T
    WILSON, GA
    MOSSBERG, TW
    OPTICS LETTERS, 1995, 20 (01) : 91 - 93
  • [46] Experimental demonstration of impulse-equivalent time-domain optical memory
    Shen, XA
    Kachru, R
    OPTICS LETTERS, 1996, 21 (24) : 2020 - 2022
  • [47] Time-domain system identification modeling for microwave structures
    Chtchekatourov, V
    Vietzorreck, L
    Fisch, W
    Russer, P
    MMET 2000: INTERNATIONAL CONFERENCE ON MATHEMATICAL METHODS IN ELECTROMAGNETIC THEORY, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2000, : 137 - 139
  • [48] A Self-Calibration Imaging Method for Microwave Staring Correlated Imaging Radar With Time Synchronization Errors
    Yuan, Bo
    Jiang, Zheng
    Zhang, Jianlin
    Guo, Yuanyue
    Wang, Dongjin
    IEEE SENSORS JOURNAL, 2021, 21 (03) : 3471 - 3485
  • [49] Time domain reflectometry field calibration in the Little Washita River Experimental Watershed
    Heathman, GC
    Starks, PJ
    Brown, MA
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2003, 67 (01) : 52 - 61
  • [50] Experimental demonstration of continuously variable optical encoding in a hybrid imaging system
    Demenikov, Mads
    Muyo, Gonzalo
    Harvey, Andrew R.
    OPTICS LETTERS, 2010, 35 (12) : 2100 - 2102