Experimental Demonstration of In-Place Calibration for Time Domain Microwave Imaging System

被引:3
|
作者
Kwon, S. [1 ,2 ,3 ]
Son, S. [4 ]
Lee, K. [4 ]
机构
[1] Ewha Womans Univ, Dept Elect Engn, Seoul, South Korea
[2] Natl Canc Ctr, Ctr Specif Organs Canc, Goyang, South Korea
[3] Hanwha Syst, Team Software Radar, Yongin, Gyeonggi Do, South Korea
[4] ETRI, Radio Technol Res Dept, Daejeon, South Korea
关键词
microwave imaging; time domain measurement system; calibration; breast cancer; BREAST-CANCER DETECTION; RADAR; TISSUE;
D O I
10.1002/2017RS006399
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
In this study, the experimental demonstration of in-place calibration was conducted using the developed time domain measurement system. Experiments were conducted using three calibration methodsin-place calibration and two existing calibrations, that is, array rotation and differential calibration. The in-place calibration uses dual receivers located at an equal distance from the transmitter. The received signals at the dual receivers contain similar unwanted signals, that is, the directly received signal and antenna coupling. In contrast to the simulations, the antennas are not perfectly matched and there might be unexpected environmental errors. Thus, we experimented with the developed experimental system to demonstrate the proposed method. The possible problems with low signal-to-noise ratio and clock jitter, which may exist in time domain systems, were rectified by averaging repeatedly measured signals. The tumor was successfully detected using the three calibration methods according to the experimental results. The cross correlation was calculated using the reconstructed image of the ideal differential calibration for a quantitative comparison between the existing rotation calibration and the proposed in-place calibration. The mean value of cross correlation between the in-place calibration and ideal differential calibration was 0.80, and the mean value of cross correlation of the rotation calibration was 0.55. Furthermore, the results of simulation were compared with the experimental results to verify the in-place calibration method. A quantitative analysis was also performed, and the experimental results show a tendency similar to the simulation.
引用
收藏
页码:429 / 439
页数:11
相关论文
共 50 条
  • [21] Analog Signal Processing: A Time-Domain Demonstration of Microwave Differentiation
    Percaz, Jon M.
    Chudzik, Magdalena
    Calero, Ibai
    Teberio, Fernando
    Arregui, Ivan
    Lopetegi, Txema
    Arnedo, Israel
    Laso, Miguel A. G.
    2018 48TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2018, : 870 - 873
  • [22] Hybrid Artifact Removal for Breast Imaging Applied to a Time-Domain Microwave System
    Santorelli, Adam
    Hazarika, Pragyan
    Popovic, Milica
    Elahi, Adnan
    O'Halloran, Martin
    2016 17TH INTERNATIONAL SYMPOSIUM ON ANTENNA TECHNOLOGY AND APPLIED ELECTROMAGNETICS (ANTEM), 2016,
  • [23] Super-Resolution Time Domain Reflectometry Method for Microwave Imaging System Applications
    Mahdiyar, O.
    Mazinan, A. H.
    Pourmina, M. A.
    Naser-Moghaddasi, M.
    IETE JOURNAL OF RESEARCH, 2019, 68 (01) : 368 - 378
  • [24] Experimental Investigation of the Accuracy of an Ultrawideband Time-Domain Microwave-Tomographic System
    Zeng, Xuezhi
    Fhager, Andreas
    Linner, Peter
    Persson, Mikael
    Zirath, Herbert
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (12) : 3939 - 3949
  • [25] Experimental demonstration of a flexible time-domain quantum channel
    Xing, Xingxing
    Feizpour, Amir
    Hayat, Alex
    Steinberg, Aephraim M.
    OPTICS EXPRESS, 2014, 22 (21): : 25128 - 25136
  • [26] Research on hybrid domain TDICMOS imaging technology based on imaging time calibration
    Liang N.
    Zhai L.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (02):
  • [27] A Practical UWB Microwave Imaging System Using Time-Domain DORT for Tumor Detection
    Sadeghi, S.
    Faraji-Dana, R.
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2016, 31 (06): : 692 - 699
  • [28] Demonstration of a microwave spectrum analyzer based on time domain processing of ultrafast pulses
    Saperstein, RE
    Xie, XB
    Yu, PKL
    Fainman, Y
    2005 Conference on Lasers & Electro-Optics (CLEO), Vols 1-3, 2005, : 1109 - 1111
  • [29] Experimental performances of Antennas for a proposed Microwave Tomography System using the time-domain approach
    Padhi, S. K.
    Fhager, A.
    Persson, M.
    Howard, J.
    2009 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM AND USNC/URSI NATIONAL RADIO SCIENCE MEETING, VOLS 1-6, 2009, : 856 - +
  • [30] Accuracy Evaluation of Ultrawideband Time Domain Systems for Microwave Imaging
    Zeng, Xuezhi
    Fhager, Andreas
    Persson, Mikael
    Linner, Peter
    Zirath, Herbert
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2011, 59 (11) : 4279 - 4285