Current-density imaging using ultra-low-field MRI with adiabatic pulses

被引:11
作者
Nieminen, Jaakko O. [1 ]
Zevenhoven, Koos C. J. [1 ]
Vesanen, Panu T. [1 ]
Hsu, Yi-Cheng [1 ,2 ]
Ilmoniemi, Risto J. [1 ]
机构
[1] Aalto Univ, Sch Sci, Dept Biomed Engn & Computat Sci, FI-00076 Aalto, Finland
[2] Natl Taiwan Univ, Dept Math, TW-10617 Taipei, Taiwan
基金
芬兰科学院;
关键词
Ultra-low-field MRI; Current-density imaging; Adiabaticity; Prepolarization; Rotation-free; SQUID SYSTEM; CONDUCTIVITY; RECONSTRUCTION; MREIT; MEG;
D O I
10.1016/j.mri.2013.07.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) allows measurement of electric current density in an object. The measurement is based on observing how the magnetic field of the current density affects the associated spins. However, as high-field MRI is sensitive to static magnetic field variations of only the field component along the main field direction, object rotations are typically needed to image three-dimensional current densities. Ultra-low-field (ULF) MRI, on the other hand, with B-0 on the order of 10-100 mu T, allows novel MRI sequences. We present a rotation-free method for imaging static magnetic fields and current densities using ULF MM. The method utilizes prepolarization pulses with adiabatic switch-off ramps. The technique is designed to reveal complete field and current-density information without the need to rotate the object. The method may find applications, e.g., in conductivity imaging. We present simulation results showing the feasibility of the sequence. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
[31]   Ultra-low field MRI food inspection system prototype [J].
Kawagoe, Satoshi ;
Toyota, Hirotomo ;
Hatta, Junichi ;
Ariyoshi, Seiichiro ;
Tanaka, Saburo .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2016, 530 :104-108
[32]   Current density imaging sequence for monitoring current distribution during delivery of electric pulses in irreversible electroporation [J].
Igor Serša ;
Matej Kranjc ;
Damijan Miklavčič .
BioMedical Engineering OnLine, 14
[33]   Ultra-sensitive SQUID systems for applications in biomagnetism and ultra-low field MRI [J].
Koerber, Rainer ;
Kieler, Oliver ;
Hommen, Peter ;
Hoefner, Nora ;
Storm, Jan-Hendrik .
2019 IEEE INTERNATIONAL SUPERCONDUCTIVE ELECTRONICS CONFERENCE (ISEC), 2019,
[34]   Magnetization transfer imaging using non-balanced SSFP at ultra-low field [J].
Balaji, Sharada ;
Wiley, Neale ;
Dvorak, Adam ;
Padormo, Francesco ;
Teixiera, Rui P. A. G. ;
Poorman, Megan E. ;
Mackay, Alex ;
Wood, Tobias ;
Cassidy, Adam R. ;
Traboulsee, Anthony ;
Li, David K. B. ;
Vavasour, Irene ;
Williams, Steven C. R. ;
Deoni, Sean C. L. ;
Ljungberg, Emil ;
Kolind, Shannon H. .
MAGNETIC RESONANCE IN MEDICINE, 2025, :602-614
[35]   First-in-human breast imaging study with ultra-low field MRI for compact proton therapy systems [J].
Longarino, Friderike K. ;
Shen, Sheng ;
Koonjoo, Neha ;
Yan, Susu ;
Jimenez, Rachel B. ;
Rosen, Matthew S. ;
Bortfeld, Thomas R. .
RADIOTHERAPY AND ONCOLOGY, 2024, 194 :S3776-S3779
[36]   Toward a magnetic resonance electrical impedance tomography in ultra-low field: A direct magnetic resonance imaging method by an external alternating current [J].
Lee, Seong-Joo ;
Shim, Jeong Hyun ;
Yu, Kwon Kyu ;
Hwang, Seong-min ;
Oh, Sangwon ;
Hilschenz, Ingo ;
Kim, Kiwoong .
APPLIED PHYSICS LETTERS, 2018, 112 (15)
[37]   Increase of nuclear magnetic resonance signal in ultra-low-field by hyperpolarization of 131Xe by spin-exchange optical pumping [J].
Takeda S. ;
Kumagai H. .
IEEJ Transactions on Electronics, Information and Systems, 2017, 137 (04) :604-606
[38]   Ultra-Low Field MRI Food Inspection System Using HTS-SQUID with Flux Transformer [J].
Tanaka, Saburo ;
Kawagoe, Satoshi ;
Demachi, Kazuma ;
Hatta, Junichi .
IEICE TRANSACTIONS ON ELECTRONICS, 2018, E101C (08) :680-684
[39]   Current Density Imaging Using Directly Measured Harmonic Bz Data in MREIT [J].
Park, Chunjae ;
Kwon, Oh In .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
[40]   Microscopic investigation of the resonant mechanism for the implementation of nc-MRI at ultra-low field MRI [J].
Cassara, A. M. ;