A Input-Series- and Output-Parallel-Connected Inverter System for High-Input-Voltage Applications

被引:77
作者
Chen, Wu [1 ]
Zhuang, Kai [2 ]
Ruan, Xinbo [3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Aeropower Sci Tech Ctr, Coll Automat Engn, Nanjing 210016, Peoples R China
[2] GE Cons&Ind, Asia Technol Ctr, Shanghai 201203, Peoples R China
[3] Huazhong Univ Sci & Technol, Coll Elect & Elect Engn, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Input-series and output-parallel; inverter; sharing of input voltage; sharing of output current; three-loop control strategy; DC-DC CONVERTERS; SHARING CONTROL; CIRCUIT; PERFORMANCE; CONTROLLER; DESIGN;
D O I
10.1109/TPEL.2009.2019578
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the configuration and control strategy for input-series-and output-parallel- (ISOP) connected inverter system, which is constructed by connecting multiple inverters in series at input sides and parallel at output sides, such that the inverters share the input voltage and load current equally. The proposed configuration is suitable for high-input-voltage applications. In order to ensure the proper operation of ISOP inverter system, equal sharing of input voltage and sharing of output current among the constituent inverters must be ensured. The relationship between input voltage sharing (IVS) and output current sharing (OCS) is analyzed in this paper. In order to realize equilibrium among the constituent inverters, a three-loop control strategy, consisting of a common output voltage loop, IVS loops, and individual inner current loops, is proposed. The common output voltage loop regulates the inverter system at desired output voltage and provides the basic reference for inner current loops, which is adjusted by the IVS loops to achieve IVS. Both the output current and the output filter inductor current of the individual inverter can be chosen as the feedback signal for the inner current loop and the difference is compared. A 2-kVA two-module ISOP inverter system prototype is fabricated and tested in the laboratory and the experimental results verify the proposed control strategy.
引用
收藏
页码:2127 / 2137
页数:11
相关论文
共 33 条
  • [1] Active input-voltage and load-current sharing in input-series and output-parallel connected modular DC-DC converters using dynamic input-voltage reference scheme
    Ayyanar, R
    Giri, R
    Mohan, N
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (06) : 1462 - 1473
  • [2] BEKIAROV SB, P IEEE APPL POW EL C, P597
  • [3] CHEN W, P IEEE APPL POW EL C, P1531
  • [4] Fault tolerant circuit topology and control method for input-series and output-parallel modular dc-dc converters
    Choudhary, Vijay
    Ledezma, Enrique
    Ayyanar, Raja
    Button, Robert M.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (01) : 402 - 411
  • [5] Erickson R. W., 2001, Fundamentals of Power Electronics, V2nd, DOI 10.1007/b100747
  • [6] GIRI R, P IEEE APPL POW EL C, P1751
  • [7] Common-duty-ratio control of input-series connected modular DC-DC converters with active input voltage and load-current sharing
    Giri, Ramesh
    Choudhary, Vijay
    Ayyanar, Raja
    Mohan, Ned
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (04) : 1101 - 1111
  • [8] Output impendance design of parallel-connected UPS inverters with wireless load-sharing control
    Guerrero, JM
    de Vicuña, LG
    Matas, J
    Castilla, M
    Miret, J
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (04) : 1126 - 1135
  • [9] A wireless controller to enhance dynamic performance of parallel inverters in distributed generation systems
    Guerrero, JM
    de Vicuña, LG
    Matas, J
    Castilla, M
    Miret, J
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (05) : 1205 - 1213
  • [10] HE Z, P IEEE POW EL SPEC C, P222