There is a demonstrated need for high-rate processes, for the treatment of storm induced sewer overflows, that are capable of removing particulate solids down to at least 10 microns in size. Chemical coagulation processes are capable of producing a high quality treated sewage effluent that would be suitable for discharge to a receiving water such as a separate stormwater system. Compact, high-rate methods of solids separation within these processes will make them more attractive for use in areas where land is expensive or unavailable for large storage basins or settling tanks. Two approaches that are being developed at the CSIRO, Division of Chemicals and Polymers, appear to fulfil this requirement; these are magnetite assisted sedimentation and a high-rate filtration process. Both approaches combine the advantages of chemical coagulation with a high-rate separation of the flocculated solids and are discussed in this paper. Copyright (C) 1996 IAWQ. Published by Elsevier Science Ltd.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 50 条
  • [1] High rate filtration for local treatment of combined sewer overflow
    Helness, H.
    Sun, C.
    Damman, S.
    Ahmadi, M.
    Raspati, G.
    Bjerkelund, V
    Moldestad, G.
    Hattori, K.
    Kato, T.
    Ando, N.
    WATER SCIENCE AND TECHNOLOGY, 2019, 79 (06) : 1206 - 1213
  • [2] Overflow rate of high-rate settlers
    Vukovic, Z
    WATER POLLUTION V: MODELLING, MEASURING AND PREDICTION, 1999, 1 : 77 - 83
  • [3] High-rate sedimentation for wastewater treatment processes
    Jimenez, B
    Ramos, J
    ENVIRONMENTAL TECHNOLOGY, 1997, 18 (11) : 1099 - 1110
  • [4] High-rate sedimentation for wastewater treatment processes
    Instituto de Ingenieriáa, UNAM, Apdo. Postal 70-472, 04510 Mexico, D.F., Mexico
    ENVIRON. TECHNOL., 11 (1099-1110):
  • [5] HIGH-RATE COLIFORM DISINFECTION OF STORMWATER OVERFLOW
    HAAS, CN
    LONGLEY, K
    SELFRIDGE, T
    RESEARCH JOURNAL OF THE WATER POLLUTION CONTROL FEDERATION, 1990, 62 (03): : 282 - 287
  • [6] High-rate wet weather solution reins in sewer overflows
    不详
    WEM-WATER ENGINEERING & MANAGEMENT, 2003, 150 (03): : 12 - 12
  • [7] HIGH-RATE BIOLOGICAL TREATMENT
    ASKEW, MW
    CHEMISTRY & INDUSTRY, 1981, (13) : 448 - 453
  • [8] Combined sewer overflow treatment - Knowledge or speculation
    Geiger, WF
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (10) : 1 - 8
  • [9] Planning and design of Combined Sewer Overflow Treatment
    Zukovs, G
    Marsalek, J
    WATER QUALITY RESEARCH JOURNAL OF CANADA, 2004, 39 (04): : 439 - 448
  • [10] Treatment Shaft for Combined Sewer Overflow Detention
    Wright, Steven J.
    Ghalib, Saad
    Eloubaidy, Aziz
    WATER ENVIRONMENT RESEARCH, 2010, 82 (05) : 434 - 439