A simulation of portable PET with a new geometric image reconstruction method

被引:0
|
作者
Kawatsu, Shoji
Ushiroya, Noboru
机构
[1] Kyoritu Gen Hosp, Dept Radiol, Atsuta Ku, Nagoya, Aichi 4568611, Japan
[2] Natl Ctr Geriatr & Gerontol, Natl Inst Longev Sci, Dept Brain Sci & Mol Imaging, Aichi 4748522, Japan
[3] Wakayama Natl Coll Technol, Dept Gen Educ, Wakayama 6440023, Japan
关键词
PET; image reconstruction;
D O I
10.1016/j.nima.2006.08.127
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method is proposed for three-dimensional positron emission tomography image reconstruction. The method uses the elementary geometric property of line of response whereby two lines of response, which originate from radioactive isotopes in the same position, lie within a few millimeters distance of each other. The method differs from the filtered back projection method and the iterative reconstruction method. The method is applied to a simulation of portable positron emission tomography. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:445 / 447
页数:3
相关论文
共 50 条
  • [41] PET image reconstruction method based on Mumford-Shah regularization
    Hu, Yining
    Zhou, Jian
    Luo, Limin
    Shuju Caiji Yu Chuli/Journal of Data Acquisition and Processing, 2007, 22 (04): : 391 - 395
  • [42] An image reconstruction method with a locally adaptive gating scheme for PET data
    Wang, Jizhe
    Dong, Yun
    Li, Hongdi
    Feng, Tao
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (16):
  • [43] Effect of PET-MR Inconsistency in the Kernel Image Reconstruction Method
    Deidda, Daniel
    Karakatsanis, N. A.
    Robson, Philip M.
    Efthimiou, Nikos
    Fayad, Zahi A.
    Aykroyd, Robert G.
    Tsoumpas, Charalampos
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 400 - 409
  • [44] An improved PET image reconstruction method based on super-resolution
    Wang, Ying
    Zhang, Xuezhu
    Zhang, Mengxi
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Yang, Yongfeng
    Hu, Zhanli
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 946
  • [45] An improved patch-based regularization method for PET image reconstruction
    Gao, Juan
    Liu, Qiegen
    Zhou, Chao
    Zhang, Weiguang
    Wan, Qian
    Hu, Chenxi
    Gu, Zheng
    Liang, Dong
    Liu, Xin
    Yang, Yongfeng
    Zheng, Hairong
    Hu, Zhanli
    Zhang, Na
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (02)
  • [46] Image reconstruction and image fusion (PET/CT)
    Yap, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1346 - 1346
  • [47] A NEW APPROACH TO 3-DIMENSIONAL IMAGE-RECONSTRUCTION IN PET
    ERLANDSSON, K
    STRAND, SE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1438 - 1443
  • [48] New Challenges for PET Image Reconstruction for Total-Body Imaging
    Efthimiou, Nikos
    PET CLINICS, 2020, 15 (04) : 453 - 461
  • [49] Evaluation of a new 4D PET image reconstruction method with respiratory motion compensation in a CHO study
    Chen, Si
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [50] AN IMPROVED 3DRP PET IMAGE RECONSTRUCTION METHOD WITH REBINNED DIRECT IMAGE ESTIMATE
    Jeng, Wei-Min
    Wang, Hsuan-Hui
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2006, 18 (05):