Performance analysis of tower solar aided coal-fired power plant with thermal energy storage

被引:19
作者
Jiang, Yue [1 ]
Duan, Liqiang [1 ]
Yang, Ming [1 ]
Tong, Yongjing [1 ]
Pang, Liping [1 ]
机构
[1] North China Elect Power Univ, Key Lab Power Stn Energy Transfer Convers & Syst, Natl Thermal Power Engn & Technol Res Ctr, Sch Energy Power & Mech Engn,Minist Educ, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar tower; Thermal energy storage; Double reheat ultra-supercritical unit; Economic analysis; Carbon emission reduction; DOUBLE-SOURCE BOILER; GENERATION SYSTEM; OPTIMIZATION; OPERATION; EXERGY; MODES; HEAT; SAPG;
D O I
10.1016/j.applthermaleng.2022.118101
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel tower solar aided coal-fired power generation (TSACPG) system with thermal energy storage is proposed in this paper. Based on the principle of energy grade matching and cascade utilization, the high-temperature solar energy is used to heat the first and second reheat steam extracted from the boiler and the low temperature solar energy is used to heat the boiler feed water. The maximum steam extraction mass flow rates of the boiler under different load rates are obtained and the thermal performances are also analyzed. The results show that the maximum steam extraction mass flow rates from the first and second reheat part of boiler are 69.7 kg/s and 37 kg/s in 100 %THA (Turbine Heat Acceptance), 78.7 kg/s and 37 kg/s in 90 %THA, 81 kg/s and 31.4 kg/s in 75 %THA, 76.3 kg/s and 31 kg/s in 60 %THA, 68.2 kg/s and 31.2 kg/s in 50 %THA load, respectively. And the standard coal consumption rates can be reduced by 39.85 g/kWh, 39.47 g/kWh, 38.08 g/ kWh, 35.50 g/kWh and 35.25 g/kWh, respectively. Both the boiler thermal efficiency and overall thermal efficiency of the TSACPG system descend sightly and the boiler exergy efficiency ascends. With the decline of the load, the solar-to-electricity efficiency, the power output and the proportion of solar power generation descend gradually. And they can reach up to 28.62%, 120.90 MW and 18.32% in 100 %THA load, respectively. The economic performance analysis of the TSACPG system is carried out. The system configuration and investment corresponding to different typical days, different thermal energy storage hours and capacities are considered. The payback times and the levelized costs of electricity of the solar field in different DNI level regions are analyzed. The results show that these two evaluation indices are the lowest in high level DNI region and they are on the contrary in low level DNI region. As for the environmental protection, the CO2 emission rates are reduced by 69.26 g/kWh in 100 %THA, 68.61 g/kWh in 90 %THA, 66.19 g/kWh in 75 %THA, 61.69 g/kWh in 60 %THA and 61.26 g/kWh in 50 %THA load, respectively. The maximum annual CO2 emission can be reduced about 526739.55 tons. The renewable energy and traditional fossil energy are integrated organically in this study and the low-carbon transformation of coal-fired power generation system is further promoted. The study also contributes to the realization of both the carbon peak and the carbon neutralization.
引用
收藏
页数:13
相关论文
共 38 条
  • [11] Annual performance analysis and optimization of a solar tower aided coal-fired power plant
    Li, Chao
    Zhai, Rongrong
    Yang, Yongping
    Patchigolla, Kumar
    Oakey, John E.
    Turner, Peter
    [J]. APPLIED ENERGY, 2019, 237 : 440 - 456
  • [12] Thermal performance of different integration schemes for a solar tower aided coal-fired power system
    Li, Chao
    Zhai, Rongrong
    Yang, Yongping
    Patchigolla, Kumar
    Oakey, John E.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 171 : 1237 - 1245
  • [13] Off-design thermodynamic performances of a solar tower aided coal-fired power plant for different solar multiples with thermal energy storage
    Li, Chao
    Yang, Zhiping
    Zhai, Rongrong
    Yang, Yongping
    Patchigolla, Kumar
    Oakey, John E.
    [J]. ENERGY, 2018, 163 : 956 - 968
  • [14] Optimization of a heliostat field layout using hybrid PSO-GA algorithm
    Li, Chao
    Zhai, Rongrong
    Liu, Hongtao
    Yang, Yongping
    Wu, Hao
    [J]. APPLIED THERMAL ENGINEERING, 2018, 128 : 33 - 41
  • [15] Coupling performance analysis of a solar aided coal-fired power plant
    Li, Jianlan
    Yu, Xiucheng
    Wang, Jizhou
    Huang, Shuhong
    [J]. APPLIED THERMAL ENGINEERING, 2016, 106 : 613 - 624
  • [16] Off-design thermodynamic performances of a combined solar tower and parabolic trough aided coal-fired power plant
    Liu, Hongtao
    Zhai, Rongrong
    Patchigolla, Kumar
    Turner, Peter
    Yang, Yongping
    [J]. APPLIED THERMAL ENGINEERING, 2021, 183
  • [17] Multi-objective robust optimization of a solar power tower plant under uncertainty
    Luo, Yan
    Wang, Zhiyuan
    Zhu, Jiamin
    Lu, Tao
    Xiao, Gang
    Chu, Fengming
    Wang, Ruixing
    [J]. ENERGY, 2022, 238
  • [18] Thermo-economic and sensitivity analysis of a central tower hybrid Brayton solar power plant
    Merchan, R. P.
    Santos, M. J.
    Garcia-Ferrero, J.
    Medina, A.
    Hernandez, A. Calvo
    [J]. APPLIED THERMAL ENGINEERING, 2021, 186
  • [19] Role of renewable energy sources in environmental protection: A review
    Panwar, N. L.
    Kaushik, S. C.
    Kothari, Surendra
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) : 1513 - 1524
  • [20] Exergy evaluation of a typical 330 MW solar-hybrid coal-fired power plant in China
    Peng, Shuo
    Wang, Zhaoguo
    Hong, Hui
    Xu, Da
    Jin, Hongguang
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 848 - 855