Applications of Hg(11) sensitive polyaniline Sn(IV) phosphate composite cation-exchange material in determination of Hg2+ from aqueous solutions and in making ion-selective membrane electrode

被引:70
作者
Khan, Asif Ali [1 ]
Inamuddin [1 ]
机构
[1] Aligarh Muslim Univ, Analyt & Polymer Res Lab, Dept Appl Chem, Fac Engn & Technol, Aligarh 202002, Uttar Pradesh, India
关键词
composite cation-exchanger; determination of Hg(II); polyaniline Sn(IV) phosphate; Hg(II) ion-selective membrane electrode;
D O I
10.1016/j.snb.2006.01.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polyaniline Sn(IV) phosphate an 'organic-inorganic' composite material, was prepared via sol-gel mixing of organic polymer polyaniline into the matrices of the inorganic precipitate of Sn(IV) phosphate. The ion-exchange capacity and distribution coefficients with respect to various metal ions were determined on the column of polyaniline Sn(IV) phosphate. The distribution studies showed the selectivity of Hg(II) ions by this material. However, the sensitivity level of Hg(II) ions on the composite material was determined quantitatively. Hg(II) ions were separated and determined from the binary aqueous mixtures of Hg(II)-Cu(II), Hg(II)-Ni(II), Hg(II)-Cd(II), Hg(II)-Co(II), Hg(II)-Al(III), etc. For the determination of Hg(II) ions in aqueous solutions, a Hg(II) ion sensitive membrane electrode was prepared by means of this composite cation-exchanger as the electroactive material. The membrane electrode was mechanically stable with quick response time and could be operated over a wide pH range with a slope of 30 mV per decade change in a linear concentration range of 1 x 10(-1) to 1 x 10(-6) M. The selectivity coefficients were determined by the mixed solution method and revealed that the electrode was selective for Hg(II) in the presence of interfering cations. The practical utility of this electrode was established by employing it as an indicator electrode in the potentiometric titration of Hg(II). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 18
页数:9
相关论文
共 52 条
[1]  
Amarchand S, 2000, ELECTROANAL, V12, P522, DOI 10.1002/(SICI)1521-4109(200005)12:7<522::AID-ELAN522>3.0.CO
[2]  
2-D
[3]   An ion-selective electrode for acetate based an a urea-functionalized porphyrin as a hydrogen-bonding ionophore [J].
Amemiya, S ;
Bühlmann, P ;
Umezawa, Y ;
Jagessar, RC ;
Burns, DH .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1049-1054
[4]   PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2502-2505
[5]   Thiocyanate-selective electrodes based on nickel and iron phthalocyanines [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :137-143
[6]  
[Anonymous], 1969, ION SEL EL REV, V1, P139
[7]   LIQUID-STATE HG-2+-SENSITIVE ELECTRODE [J].
BAIULESCU, GE ;
COSOFRET, VV .
TALANTA, 1976, 23 (09) :677-678
[8]  
CATRALL RW, 1976, ANAL CHEM, V48, P552
[9]   Flow-injection potentiometric detection of metal ions based on tungsten oxide electrode [J].
Chen, ZL ;
Alexander, PW .
ELECTROANALYSIS, 1997, 9 (02) :141-144
[10]   CESIUM-SENSITIVE ELECTRODE [J].
COETZEE, CJ ;
BASSON, AJ .
ANALYTICA CHIMICA ACTA, 1971, 57 (02) :478-&