High-performance liquid chromatographic determination of 2-hydroxypropyl-γ-cyclodextrin in different biological fluids based on cyclodextrin enhanced fluorescence

被引:7
作者
Szemán, J
Gerlóczy, A
Csabai, K
Szejtli, J
Kis, GL
Su, P
Chau, RY
Jacober, A
机构
[1] CYCLOLAB, Cyclodextrin Res & Dev Lab Ltd, H-1525 Budapest, Hungary
[2] Novartis Ophthalm AG, CH-4002 Basel, Switzerland
[3] Novartis Ophthalm Inc, Duluth, GA 30097 USA
[4] Novartis Ophthalm AG, CH-8180 Bulach, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 774卷 / 02期
关键词
2-hydroxypropyl-gamma-cyclodextrin;
D O I
10.1016/S1570-0232(02)00182-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance size exclusion chromatographic method with analyte enhanced fluorescence detection is described for the analysis of 2-hydroxypropyl-gamma-cyclodextrin (HPGCD) in different biological fluids. The principle of detection was the in situ complexation of 8-anilinonaphthalene-1-sulfonic acid (ANS) by HPGCD. When HPGCD eluted from the column the increased fluorescence was measured at excitation and emission wavelengths of 270 and 512 nm, respectively. Solid-phase extraction cleanup and concentration of samples resulted in higher than 7$% recovery of HPGCD for each of the studied biological fluids. Some important details of the method development as well as the validation of the method for rabbit plasma, rabbit aqueous humour, monkey plasma and monkey urine are given. The limits of quantification varied between 1 and 10 nmol/ml (correspond to 1.5-15 mug/ml) depending on the biological matrix used. The method was successfully adapted in another laboratory proving that HPGCD had not absorbed into aqueous humour and plasma after topical application of HPGCD containing eye drop in rabbits. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 50 条
[31]   RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF PROBENECID IN BIOLOGICAL-FLUIDS [J].
HEKMAN, P ;
PORSKAMP, PATW ;
KETELAARS, HCJ ;
VANGINNEKEN, CAM .
JOURNAL OF CHROMATOGRAPHY, 1980, 182 (02) :252-256
[32]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THIOPURINE METABOLITES OF AZATHIOPRINE IN BIOLOGICAL-FLUIDS [J].
BOULIEU, R ;
LENOIR, A ;
BORY, C .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 615 (02) :352-356
[33]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF BETA-NAPHTHOFLAVONE IN BIOLOGICAL-FLUIDS [J].
ADEDOYIN, A ;
AARONS, L ;
HOUSTON, JB .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 416 (01) :160-164
[34]   SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CAPTOPRIL IN BIOLOGICAL-FLUIDS [J].
SHEN, G ;
TIAN, WR ;
WANG, SX .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 582 (1-2) :258-262
[35]   Linking the concentrations of itraconazole and 2-hydroxypropyl-β-cyclodextrin in human intestinal fluids after oral intake of Sporanox® [J].
Berben, Philippe ;
Stappaerts, Jef ;
Vink, Matthias J. A. ;
Dominguez-Vega, Elena ;
Somsen, Govert W. ;
Brouwers, Joachim ;
Augustijns, Patrick .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2018, 132 :231-236
[36]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MULTIVITAMIN PREPARATIONS USING A CHEMICALLY BONDED CYCLODEXTRIN STATIONARY PHASE [J].
ELGIZAWY, SM ;
AHMED, AN ;
ELRABBAT, NA .
ANALYTICAL LETTERS, 1991, 24 (07) :1173-1181
[37]   UTILITY OF CYCLODEXTRIN IN MOBILE PHASE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BUFADIENOLIDES [J].
SHIMADA, K ;
KURATA, Y ;
OE, T .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (03) :493-504
[38]   UTILITY OF CYCLODEXTRIN IN MOBILE PHASE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF CARDENOLIDES [J].
SHIMADA, K ;
OE, T ;
KANNO, C ;
NAMBARA, T .
ANALYTICAL SCIENCES, 1988, 4 (04) :377-380
[39]   DETERMINATION OF PHOLCODINE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
CHEN, ZR ;
SIEBERT, DM ;
SOMOGYI, AA ;
BOCHNER, F .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 424 (01) :170-176
[40]   RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF DAPSONE AND MONOACETYLDAPSONE IN BIOLOGICAL-FLUIDS [J].
ZUIDEMA, J ;
MODDERMAN, ESM ;
HILBERS, HW ;
MERKUS, FWHM .
JOURNAL OF CHROMATOGRAPHY, 1980, 182 (01) :130-135