The femoral neck-shaft angle on plain radiographs: a systematic review

被引:81
作者
Boese, Christoph Kolja [1 ]
Dargel, Jens [1 ]
Oppermann, Johannes [1 ]
Eysel, Peer [1 ]
Scheyerer, Max Joseph [1 ]
Bredow, Jan [1 ]
Lechler, Philipp [2 ]
机构
[1] Univ Hosp Cologne, Dept Orthopaed & Trauma Surg, D-50931 Cologne, Germany
[2] Univ Giessen & Marburg, Dept Trauma Hand & Reconstruct Surg, Marburg, Germany
关键词
Neck shaft angle; NSA; Caput-collum-diaphyseal angle; CCD; Hip anatomy; Hip arthroplasty; TOTAL HIP-ARTHROPLASTY; PROXIMAL FEMUR; ROENTGENOGRAPHIC EVALUATION; CEREBRAL-PALSY; ANATOMIC BASIS; RELIABILITY; OSTEOARTHRITIS; MORPHOLOGY; FRACTURE; JOINT;
D O I
10.1007/s00256-015-2236-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The femoral neck-shaft angle (NSA) is an important measure for the assessment of the anatomy of the hip and planning of operations. Despite its common use, there remains disagreement concerning the method of measurement and the correction of hip rotation and femoral version of the projected NSA on conventional radiographs. We addressed the following questions: (1) What are the reported values for NSA in normal adult subjects and in osteoarthritis? (2) Is there a difference between non-corrected and rotation-corrected measurements? (3) Which methods are used for measuring the NSA on plain radiographs? (4) What could be learned from an analysis of the intra- and interobserver reliability? A systematic literature search was performed including 26 publications reporting the measurement of the NSA on conventional radiographs. The mean NSA of healthy adults (5,089 hips) was 128.8A degrees (98-180A degrees) and 131.5A degrees (115-155A degrees) in patients with osteoarthritis (1230 hips). The mean NSA was 128.5A degrees (127-130.5A degrees) for the rotation-corrected and 129.5A degrees (119.6-151A degrees) for the non-corrected measurements. Our data showed a high variance of the reported neck-shaft angles. Notably, we identified the inconsistency of the published methods of measurement as a central issue. The reported effect of rotation-correction cannot be reliably verified.
引用
收藏
页码:19 / 28
页数:10
相关论文
共 54 条
  • [1] Patterns of sexual, bilateral and interpopulational variation in human femoral neck-shaft angles
    Anderson, JY
    Trinkaus, E
    [J]. JOURNAL OF ANATOMY, 1998, 192 : 279 - 285
  • [2] Anatomy of the dysplastic hip and consequences for total hip arthroplasty
    Argenson, Jean-Noel A.
    Flecher, Xavier
    Parratte, Sebastien
    Aubaniac, Jean-Manuel
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) : 40 - 45
  • [3] Radiographic preoperative templating of extra-offset cemented THA implants: How reliable is it and how does it affect survival?
    Bachour, F.
    Marchetti, E.
    Bocquet, D.
    Vasseur, L.
    Migaud, H.
    Girard, J.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (07) : 760 - 768
  • [4] Radiographic study of the hip joint to determine anthropometric parameters for Indian population
    Bagaria, Vaibhav
    Deshpande, Shirish
    Kuthe, Abhay
    Rasalkar, Darshana D.
    Paunipagar, Bhawan K.
    Madhugiri, Tanushree Subhash
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : 312 - 316
  • [5] The influence of pre-existing radiographic osteoarthritis on functional outcome after trochanteric fracture
    Boese, Christoph Kolja
    Buecking, Benjamin
    Schwarting, Tim
    Debus, Florian
    Ruchholtz, Steffen
    Bliemel, Christoph
    Frink, Michael
    Lechler, Philipp
    [J]. INTERNATIONAL ORTHOPAEDICS, 2015, 39 (07) : 1405 - 1410
  • [6] Reproducibility of radiographic hip measurements in adults
    Bouttier, Ronan
    Morvan, Johanne
    Mazieres, Bernard
    Rat, Anne-Christine
    Ziegler, Liana Euller
    Fardellone, Patrice
    Fautrel, Bruno
    Guillemin, Francis
    Pouchot, Jacques
    Roux, Christian
    Coste, Joel
    Saraux, Alain
    [J]. JOINT BONE SPINE, 2013, 80 (01) : 52 - 56
  • [7] BRUCKL R, 1986, RADIOLOGE, V26, P305
  • [8] Buecking B, 2015, INT ORTHOP
  • [9] Relationship Between Proximal Femoral and Acetabular Alignment in Normal Hip Joints Using 3-Dimensional Computed Tomography
    Buller, Leonard T.
    Rosneck, James
    Monaco, Feno M.
    Butler, Robert
    Smith, Travis
    Barsoum, Wael K.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (02) : 367 - 375
  • [10] Chiu C K, 2009, Med J Malaysia, V64, P22