Performance of Legiolert Test vs. ISO 11731 to Confirm Legionella pneumophila Contamination in Potable Water Samples

被引:20
作者
Scaturro, Maria [1 ]
Buffoni, Matteo [1 ]
Girolamo, Antonietta [1 ]
Cristino, Sandra [2 ]
Girolamini, Luna [2 ]
Mazzotta, Marta [2 ]
Sabattini, Maria Antonietta Bucci [3 ]
Zaccaro, Cristina Maria [3 ]
Chetti, Leonarda [3 ]
Bella, Antonino [1 ]
Rota, Maria Cristina [1 ]
Ricci, Maria Luisa [1 ]
机构
[1] Natl Inst Hlth, Dept Infect Dis, Viale Regina Elena 299, I-00161 Rome, Italy
[2] Univ Bologna, Dept Biol Geol & Environm Sci, Via San Giacomo 12, I-40126 Bologna, Italy
[3] Hlth Protect Agcy Bologna, Reference Lab Environm Control, Via Trachini 17, I-40138 Bologna, Italy
[4] Hlth Protect Agcy, Reference Lab Environm Control, Viale Roma 7-E, I-28100 Rome, Italy
来源
PATHOGENS | 2020年 / 9卷 / 09期
关键词
Legionella; Legiolert; ISO; 11731; plate culture; potable water samples; LEGIONNAIRES-DISEASE; MONITORING LEGIONELLA; OUTBREAK; PCR; ACCURACY; DIAGNOSIS; CULTURE;
D O I
10.3390/pathogens9090690
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Detection and enumeration of Legionella in water samples is of great importance for risk assessment analysis. The plate culture method is the gold standard, but has received several well-known criticisms, which have induced researchers to develop alternative methods. The purpose of this study was to compare Legionella counts obtained by the analysis of potable water samples through the plate culture method and through the IDEXX liquid culture Legiolert method. Legionella plate culture, according to ISO 11731:1998, was performed using 1 L of water. Legiolert was performed using both the 10 mL and 100 mL Legiolert protocols. Overall, 123 potable water samples were analyzed. Thirty-seven (30%) of them, positive for L. pneumophila, serogroups 1 or 2-14 by plate culture, were used for comparison with the Legiolert results. The Legiolert 10 mL test detected 34 positive samples (27.6%) and the Legiolert 100 mL test detected 37 positive samples, 27.6% and 30% respectively, out of the total samples analyzed. No significant difference was found between either the Legiolert 10 mL and Legiolert 100 mL vs. the plate culture (p = 0.9 and p = 0.3, respectively) or between the Legiolert 10 mL and Legiolert 100 mL tests (p = 0.83). This study confirms the reliability of the IDEXX Legiolert test for Legionella pneumophila detection and enumeration, as already shown in similar studies. Like the plate culture method, the Legiolert assay is also suitable for obtaining isolates for typing purposes, relevant for epidemiological investigations.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 38 条
[1]  
AFNOR, 2017, T90431 AFNOR NF
[2]  
American Public Health Association (APHA), 2007, 9260 APHA
[3]  
[Anonymous], **NON-TRADITIONAL**
[4]  
[Anonymous], 2015, Linee guida di prevenzione oncologica: percorsi organizzativi e diagnostici-2015
[5]  
[Anonymous], **NON-TRADITIONAL**
[6]  
[Anonymous], **NON-TRADITIONAL**
[7]   Diagnostic Accuracy of PCR Alone and Compared to Urinary Antigen Testing for Detection of Legionella spp.: a Systematic Review [J].
Avni, Tomer ;
Bieber, Amir ;
Green, Hefziba ;
Steinmetz, Tali ;
Leibovici, Leonard ;
Paul, Mical .
JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (02) :401-411
[8]   Comparison of Legiolert and a Conventional Culture Method for Detection of Legionella pneumophila from Cooling Towers in Quebec [J].
Barrette, Isabelle .
JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (04) :1235-1240
[9]   Comparison of Legionella longbeachae and Legionella pneumophila cases in Scotland; implications for diagnosis, treatment and public health response [J].
Cameron, R. L. ;
Pollock, K. G. J. ;
Lindsay, D. S. J. ;
Anderson, E. .
JOURNAL OF MEDICAL MICROBIOLOGY, 2016, 65 :142-146
[10]   Utility of PCR, Culture, and Antigen Detection Methods for Diagnosis of Legionellosis [J].
Chen, Derrick J. ;
Procop, Gary W. ;
Vogel, Sherilynn ;
Yen-Lieberman, Belinda ;
Richter, Sandra S. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (11) :3474-3477