Shear-Wave Elastography in the Characterization of Pleural Effusions

被引:15
作者
Ozgokce, Mesut [1 ]
Durmaz, Fatma [1 ]
Yavuz, Alpaslan [1 ]
Urley, Ibrahim [2 ]
Yildiz, Hanifi [2 ]
Arslan, Harun [1 ]
Dundar, Ilyas [1 ]
Havan, Nuri [3 ]
Ogul, Havri [4 ]
机构
[1] Yuzuncu Yil Univ, Med Fac, Dept Radiol, TR-65100 Van, Turkey
[2] Yuzuncu Yil Univ, Med Fac, Dept Chest Dis, Van, Turkey
[3] Kartal Kosuyolu Res & Training Hosp, Dept Radiol, Istanbul, Turkey
[4] Ataturk Univ, Med Fac, Dept Radiol, Erzurum, Turkey
关键词
pleural effusion; elastography; ultrasonography; ATTENUATION VALUES; THORACENTESIS; FLUID; CT; DIFFERENTIATION; COMPLICATIONS; GUIDELINES; LUNG;
D O I
10.1097/RUQ.0000000000000424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to investigate the efficacy of shear-wave elastography (SWE) in the differentiation of transudative and exudative pleural effusions. This monocentric study comprised 60 cases (17 transudative, 43 exudative).Transthoracic SWE was performed in 60 cases for whom to use thoracentesis for the pleural fluid analysis was planned. The mean SWE values of each patient were recorded, and the correlation between the biochemical analysis results of pleural fluid after thoracentesis and SWE findings was evaluated. The effusion SWE values and biochemical analysis results were compared. Of the 60 patients who participated in this study, 32 (53.4) were male and 28 (46.6%) were female. The mean +/- SD age was 59 +/- 17.09 years (range = 21-89 years). Simultaneous serum biochemical analysis was performed for the patients with PE. The mean +/- SD shear-wave velocity value of the transudative fluid was calculated 2.29 +/- 0.41 (1.6-2.94), whereas the mean +/- SD shear-wave velocity value of the exudative pleural fluid was calculated as 3.29 +/- 0.63 (2.01-4.88) (P < 0.001). The receiver operating characteristic analysis showed that sensitivity and specificity were found as 91% and 76.5%, respectively, when the cutoff value was selected as 2.52 m/s in the differentiation of the transudative and exudative effusions. Shear-wave elastography may help in the differentiation of transudative and exudative of the pleural effusions.
引用
收藏
页码:164 / 168
页数:5
相关论文
共 28 条
[1]   Pleural Effusion: Characterization with CT Attenuation Values and CT Appearance [J].
Abramowitz, Yigal ;
Simanovsky, Natalia ;
Goldstein, Michael S. ;
Hiller, Nurith .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) :618-623
[2]   Diffusion-weighted MR imaging of pleural fluid:: differentiation of transudative vs exudative pleural effusions [J].
Baysal, T ;
Bulut, T ;
Gökirmak, M ;
Kalkan, S ;
Dusak, A ;
Dogan, M .
EUROPEAN RADIOLOGY, 2004, 14 (05) :890-896
[3]   WHAT IS THE ORIGIN OF PLEURAL TRANSUDATES AND EXUDATES [J].
BROADDUS, VC ;
LIGHT, RW .
CHEST, 1992, 102 (03) :658-659
[4]   THORACENTESIS - CLINICAL-VALUE, COMPLICATIONS, TECHNICAL PROBLEMS, AND PATIENT EXPERIENCE [J].
COLLINS, TR ;
SAHN, SA .
CHEST, 1987, 91 (06) :817-822
[5]  
COLT HG, 1995, CLIN CHEST MED, V16, P505
[6]   Efficacy of CT in diagnosis of transudates and exudates in patients with pleural effusion [J].
Cullu, Nesat ;
Kalemci, Serdar ;
Karakas, Omer ;
Eser, Irfan ;
Yalcin, Funda ;
Boyaci, Fatima Nurefsan ;
Karakas, Ekrem .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (02) :116-120
[7]   MR IMAGING OF PLEURAL EFFUSIONS [J].
DAVIS, SD ;
HENSCHKE, CI ;
YANKELEVITZ, DF ;
CAHILL, PT ;
YI, Y .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (02) :192-198
[8]   Exudative effusions in congestive heart failure [J].
Eid, AA ;
Keddissi, JI ;
Samaha, M ;
Tawk, MM ;
Kimmell, K ;
Kinasewitz, GT .
CHEST, 2002, 122 (05) :1518-1523
[9]   FDG PET of pleural effusions in patients with non-small cell lung cancer [J].
Erasmus, JJ ;
McAdams, HP ;
Rossi, SE ;
Goodman, PC ;
Coleman, RE ;
Patz, EF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (01) :245-249
[10]   Transudative vs exudative pleural effusions: differentiation using Gd-DTPA-enhanced MRI [J].
Frola, C ;
Cantoni, S ;
Turtulici, I ;
Leoni, C ;
Floria, F ;
Gaeta, M ;
Derchi, LE .
EUROPEAN RADIOLOGY, 1997, 7 (06) :860-864