RETRACTED: Boiler Tube Leakage Acoustic Localization Error Analysis (Retracted Article)

被引:0
|
作者
Wang, Peng [1 ]
An, Liansuo [1 ]
Jiang, Genshan [1 ]
Shen, Guoqing [1 ]
Lu, Yongxing [1 ]
机构
[1] North China Elect Power Univ, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing, Peoples R China
来源
2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC) | 2010年
基金
中国国家自然科学基金;
关键词
Acoustic; leakage localizition; time differences of arrive; generalized cross correlati; accelerationg genetic algorithm; error;
D O I
10.1109/APPEEC.2010.5448980
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Efficient and reliable operation is the main requirement of the modern power plant, hence it's significant that the boiler tube leakage source is localized precisely. The four-element acoustic array was exploited in the furnace, a set of hyperbolic equations were established and the sensors distributed for capture the leakage signal were given. The stable and sharp peak can be obtained by an approximation of the maximum likelihood (ML) estimator, which was verified via the experiment on localization of leakage. The time differences of arrival (TDOA) error level was 0.1us, the array failed to fix position as the remarkable coordinate error, while the error level was 0.01us, the coordinates error was linearized and reduced to the permitted range (less than 1m).
引用
收藏
页数:4
相关论文
共 2 条
  • [1] Boiler Tube Leakage Acoustic Localization Base on AGA
    Wang, Peng
    An, Liansuo
    Shen, Guoqing
    Shi, Jie
    Lu, Yongxing
    2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 3179 - 3183
  • [2] RETRACTED: Application of 3D Solid Modeling in Measurement and Error Evaluation of Spiral Bevel Gear (Retracted Article)
    Hua, Zhao
    Piao, Sheng
    2011 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL SCIENCE-ICEES 2011, 2011, 11 : 1662 - 1669