A study on residential energy requirement and the effect of the glazing on the optimum insulation thickness

被引:65
作者
Derradji, L. [1 ,2 ]
Imessad, K. [3 ]
Amara, M. [1 ]
Errebai, F. Boudali [1 ]
机构
[1] CNERIB, Algiers, Algeria
[2] Univ Saad Dahleb, Dept Energies Renouvelables, Blida, Algeria
[3] Ctr Dev Energies Renouvelables, Route Observ,BP 62, Bouzareah, Alger, Algeria
关键词
Experimental study; Thermal simulation; Optimum insulation thickness; Energy savings; Cooling loads; Heating loads; BUILDING WALLS; THERMAL PERFORMANCE; EXTERNAL WALLS; MEDITERRANEAN CLIMATE; ENVIRONMENTAL-IMPACT; SAVINGS; OPTIMIZATION; CAMEROON; ZONE;
D O I
10.1016/j.applthermaleng.2016.10.116
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work focuses on experimental and numerical study of a prototype building to study its thermal behavior and to compare its energy performance with those of a classical home in Algeria. Yearly cooling and heating transmission loads are calculated according to the increase of the thickness of the expanded polystyrene insulation for three different structure materials. The effect of the type of the glazing and the percentage of glazing in the wall has been studied to determine the optimum thickness of the insulation. The results of the thermal simulation showed that the inertia associated with good thermal insulation has an important role in improving thermal comfort and can reach up to 70% energy savings on heating and air conditioning. The results for cooling show that the optimum insulation thickness of expanded polystyrene vary between 1 cm and 2.5 cm, the energy savings vary between 0.5 and 1.5 $/m(2) depending on the type and the percentage of the window in the wall. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:975 / 985
页数:11
相关论文
共 33 条
[11]   Analytical periodic solution for the study of thermal performance and optimum insulation thickness of building walls in Tunisia [J].
Daouas, Naouel ;
Hassen, Zaineb ;
Aissia, Habib Ben .
APPLIED THERMAL ENGINEERING, 2010, 30 (04) :319-326
[12]  
del Coz Diaz J.J., 2006, APPL THERM ENG, V27, P1445
[13]  
Derradji L., 2014, J ENERGY ENG AM SOC, V141, P461
[14]  
Derradji L., 2012, MOROCCO
[15]  
Derradji L., 2013, RENEW ENERGY REV, V16, P709
[16]   Optimization of insulation thickness for external walls using different energy-sources [J].
Dombayci, O. Altan ;
Golcu, Mustafa ;
Pancar, Yasar .
APPLIED ENERGY, 2006, 83 (09) :921-928
[17]   The environmental impact of optimum insulation thickness for external walls of buildings [J].
Dombayci, Oe. Altan .
BUILDING AND ENVIRONMENT, 2007, 42 (11) :3855-3859
[18]   Dynamic thermal performance of three types of unfired earth bricks [J].
El Fgaier, Faycal ;
Lafhaj, Zoubeir ;
Antczak, Emmanuel ;
Chapiseau, Christophe .
APPLIED THERMAL ENGINEERING, 2016, 93 :377-383
[19]   Zero energy balance and zero on-site CO2 emission housing development in the Mediterranean climate [J].
Ferrante, A. ;
Cascella, M. T. .
ENERGY AND BUILDINGS, 2011, 43 (08) :2002-2010
[20]   Investigation on the thermal performance of different lightweight roofing structures and its effect on space cooling load [J].
Han, Jun ;
Lu, Lin ;
Yang, Hongxing .
APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) :2491-2499