BNCT dosimetry performed with a mini twin tissue-equivalent proportional counters (TEPC)

被引:20
作者
Moro, D. [1 ,2 ]
Colautti, P. [1 ]
Lollo, M. [1 ]
Esposito, J. [1 ]
Conte, V. [1 ]
De Nardo, L. [2 ]
Ferretti, A. [1 ]
Ceballos, C. [1 ]
机构
[1] Natl Inst Nucl Phys, Legnaro Natl Labs, I-35020 Legnaro, Padova, Italy
[2] Univ Padua, Dept Phys, I-35131 Padua, Italy
关键词
BNCT; Microdosimetry; TEPC; HYTHOR; TAPIRO; TAPIRO REACTOR; CALIBRATION;
D O I
10.1016/j.apradiso.2009.03.042
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The BNCT radiation field is complex because different beam components are mixed, each one having different relative biological effectiveness (RBE). Microdosimetry with tissue-equivalent proportional counters (TEPC) has proven to be an ideal dosimetric technique for mixed radiation fields, because it is able both to measure the absorbed dose and to assess the radiation field relative biological effectiveness with good accuracy. An ideal detector for BNCT should contain two TEPCs, one detector loaded with, while the other one without B-10 in order to record all beam components with a unique measurement. Moreover, Such a detector should be of tiny size in order to be able to measure in the intense BNCT radiation fields without significant pile-up effects. TEPCs have been shown to be pretty good dosimeters for mixed radiation fields. In this paper the first mini twin TEPC counter for BNCT is presented, as well as first measurement at the new HYTHOR thermal irradiation facility at TAPIRO nuclear reactor and comparison with related Monte Carlo calculations. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S171 / S174
页数:4
相关论文
共 17 条
[1]   An international dosimetry exchange for boron neutron capture therapy, Part I:: Absorbed dose measurements [J].
Binns, PJ ;
Riley, KJ ;
Harling, OK ;
Kiger, WS ;
af Rosenschöld, PMM ;
Giusti, V ;
Capala, J ;
Sköld, K ;
Auterinen, I ;
Serén, T ;
Kotiluoto, P ;
Uusi-Simola, J ;
Marek, M ;
Viererbl, L ;
Spurny, F .
MEDICAL PHYSICS, 2005, 32 (12) :3729-3736
[2]   Microdosimetric intercomparison of BNCT beams at BNL and MIT [J].
Burmeister, J ;
Riley, K ;
Coderre, JA ;
Harling, OK ;
Ma, R ;
Wielopolski, L ;
Kota, C ;
Maughan, RL .
MEDICAL PHYSICS, 2003, 30 (08) :2131-2139
[3]  
CROSSMAN JSP, 1994, RADIAT PROT DOSIM, V55, P295
[4]  
De Nardo L, 2004, PHYS MEDICA, V20, P71
[5]   BNCT microdosimetry at the tapiro reactor thermal column [J].
De Nardo, L ;
Seravalli, E ;
Rosi, G ;
Esposito, J ;
Colautti, P ;
Conte, V ;
Tornielli, G .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :579-586
[6]   Mini-TEPCs for radiation therapy [J].
De Nardo, L ;
Cesari, V ;
Donà, G ;
Magrin, G ;
Colautti, P ;
Conte, V ;
Torniellil, G .
RADIATION PROTECTION DOSIMETRY, 2004, 108 (04) :345-352
[7]   Feasibility of BNCT radiobiological experiments at the HYTHOR facility [J].
Esposito, J. ;
Ceballos, C. ;
Soncin, M. ;
Fabris, C. ;
Friso, E. ;
Moro, D. ;
Colautti, P. ;
Jori, G. ;
Rosi, G. ;
Nava, E. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (11) :2587-2593
[8]   The new hybrid thermal neutron facility at tapiro reactor for BNCT radiobiological experiments [J].
Esposito, J. ;
Rosi, G. ;
Agosteo, S. .
RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) :69-73
[9]  
GUEULETTE J, 2006, ADV NEUTRON CAPTURE, P81
[10]  
HENDRICKS J. S., 2006, LAUR063248 LOS AL NA