Effect of one overnight wear of orthokeratology lenses on tear composition

被引:32
作者
Choy, CKM [1 ]
Cho, P
Benzie, IFF
Ng, V
机构
[1] Hong Kong Polytech Univ, Dept Optometry & Radiog, Kowloon, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Sch Nursing, Kowloon, Hong Kong, Peoples R China
关键词
tears; cornea; ascorbate; protein; lactate dehydrogenase; orthokeratology;
D O I
10.1097/01.opx.0000135094.15125.4c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the effect of one night of orthokeratology lens wear on ocular surface health based on the changes in tear components, including ascorbate, urate, lactate dehydrogenase (LD), lactoferrin, lipocalin, lysozyme, secretory immunoglobulin A (slgA), and serum albumin. Methods. Changes in tear components in eight healthy young men before and after 7-h overnight ortho-k lens wear were studied. Subjects attended on two separate occasions during a 1-week period, on one occasion wearing lens overnight and on the other wearing no lens. Tears (yawn-induced) were collected by capillary tube before lens fitting and on awakening. Tear ascorbate and urate were measured by high-performance liquid chromatography; LD was measured by a commercial kit method; tear proteins were measured by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Results. Ascorbate, sIgA, albumin, and LD increased significantly overnight with and without overnight lens wear (p < 0.05); however, no significant increases were found in tear urate, lactoferrin, lipocalin, or lysozyme (p > 0.05). Without lens wear, tear ascorbate, slgA, albumin, and LD increased by 21%, 34%, 9-fold, and 13-fold, respectively (p < 0.05). With ortho-k lens wear, significant flattening of the apical curvature was observed as expected, and the increases in tear ascorbate, slgA, albumin, and LD (increases were 56%, 76%, 13-fold, and 14-fold, respectively) were significantly (p < 0.05) greater than with no lens. There was significant correlation seen between changes in albumin and LD with (r = 0.762; p = 0.037) and without (r = 0.738; p = 0.046) ortho-k lens wear. Conclusions. The result of tear ascorbate suggests that corneal cell disturbance is small after one night of ortho-k lens wear. The marked increases in albumin and LD suggest that the ocular surface is under additional hypoxic stress during overnight ortho-k lens wear.
引用
收藏
页码:414 / 420
页数:7
相关论文
共 39 条
  • [1] The effects of overnight orthokeratology lens wear on corneal thickness
    Alharbi, A
    Swarbrick, HA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (06) : 2518 - 2523
  • [2] Brubaker RF, 2000, INVEST OPHTH VIS SCI, V41, P1681
  • [3] Effects of daily and overnight wear of a novel hyper oxygen-transmissible soft contact lens on bacterial binding and corneal epithelium - A 13-month clinical trial
    Cavanagh, HD
    Ladage, PM
    Li, SL
    Yamamoto, K
    Molai, M
    Ren, DH
    Petroll, WM
    Jester, JV
    [J]. OPHTHALMOLOGY, 2002, 109 (11) : 1957 - 1969
  • [4] Corneal iron ring associated with orthokeratology lens wear
    Cho, P
    Chui, WS
    Moutford, J
    Cheung, SW
    [J]. OPTOMETRY AND VISION SCIENCE, 2002, 79 (09) : 565 - 568
  • [5] Antioxidants in tears and plasma: Inter-relationships and effect of vitamin C supplementation
    Choy, CKM
    Benzie, IFF
    Cho, P
    [J]. CURRENT EYE RESEARCH, 2003, 27 (01) : 55 - 60
  • [6] Choy CKM, 2001, INVEST OPHTH VIS SCI, V42, P3130
  • [7] Dave T, 1998, OPHTHAL PHYSL OPT, V18, P224, DOI 10.1016/S0275-5408(97)00086-0
  • [8] Recovery from hyperemia after overnight wear of low and high transmissibility hydrogel lenses
    du Toit, R
    Simpson, TL
    Fonn, D
    Chalmers, RL
    [J]. CURRENT EYE RESEARCH, 2001, 22 (01) : 68 - 73
  • [9] EFRON N, 2002, CONTACT LENS PRACTIC, P487
  • [10] FULLARD RJ, 1991, INVEST OPHTH VIS SCI, V32, P2290