Intraocular lens power calculations using a Scheimpflug camera to measure corneal power

被引:10
|
作者
Xu, K. [1 ]
Hao, Y. [1 ]
Qi, H. [1 ]
机构
[1] Peking Univ, Hosp 3, Dept Ophthalmol, Beijing 100871, Peoples R China
关键词
cornea; eyes; IOL calculation; lens; Pentacam; refractive surgery; Scheimpflug camera; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; EXCIMER-LASER SURGERY; REFRACTIVE SURGERY; EYES; PENTACAM; FORMULA; PREDICTION;
D O I
10.3109/10520295.2013.867532
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We measured corneal power using an Oculus Pentacam (R) to assess its accuracy for calculating intraocular lens (IOL) power after myopic refractive surgery. A series of corneal power measurements were performed on 22 patients (43 eyes) who had undergone myopic refractive surgery. In 37 of the 43 eyes, phacoemulsification and IOL implantation subsequently were performed. Conventional keratometry and three corneal measurements (mean true net power, central true net power, and 4.5 mm equivalent K reading) obtained using a Pentacam were analyzed and compared to values derived from the clinical history method. Prediction errors of three Pentacam corneal power measurements inserted in third generation IOL formulas also were compared. Analysis of the variance showed that only two Pentacam corneal measurements, mean true net power and central true net power, were not significantly different from those of the clinical history method. Mean true net power was correlated more closely with the clinical history method corneal power than other corneal power values. The one-sample t-test showed that of three Pentacam corneal measurements combined with third-generation formulas, only the mean true net power inserted in the SRK/T implant power calculation formula was not significantly different from zero. The percentages of eyes within +/- 0.50 D and +/- 1.00 D of the refractive prediction error of this method were 67.6% and 86.5%, respectively. Mean true net power inserted in the SRK/T formula can be used to calculate directly IOL power after myopic refractive surgery.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 50 条
  • [41] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Anders, Philipp
    Anders, Lisa-Marie
    Barbara, Adel
    Szentmary, Nora
    Langenbucher, Achim
    Gatzioufas, Zisis
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14
  • [42] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    EYE AND VISION, 2018, 5
  • [43] Reproducibility of Scheimpflug Tomography Measurements Regarding Corneal Front and Back Surface Power
    Stavridis, E.
    Eppig, T.
    Szentmary, N.
    Seitz, B.
    Langenbucher, A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (11) : 1297 - 1303
  • [44] Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery
    Holladay, Jack T.
    Hill, Warren E.
    Steinmueller, Andreas
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) : 862 - 868
  • [45] Intraocular lens power calculation after myopic excimer laser surgery: Clinical comparison of published methods
    Savini, Giacomo
    Hoffer, Kenneth J.
    Carbonelli, Michele
    Barboni, Piero
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) : 1455 - 1465
  • [46] Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery
    Lawless, Michael
    Jiang, James Y.
    Hodge, Chris
    Sutton, Gerard
    Roberts, Timothy, V
    Barrett, Graham
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (06) : 749 - 756
  • [47] Modified double-K method for intraocular lens power calculation after excimer laser corneal refractive surgery
    Saiki, Megumi
    Negishi, Kazuno
    Kato, Naoko
    Ogino, Rika
    Arai, Hiroyuki
    Toda, Ikuko
    Dogru, Murat
    Tsubota, Kazuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04) : 556 - 562
  • [48] Calculation of intraocular lens power after corneal refractive surgery
    Chan, Colin C. K.
    Hodge, Chris
    Lawless, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (07) : 640 - 644
  • [49] Intraocular Lens Power Calculation After Corneal Refractive Surgery
    Feiz, Vahid
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2010, 17 (01) : 63 - 68
  • [50] An Intraocular Lens Power Calculation Formula Based on Optical Coherence Tomography: A Pilot Study
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (06) : 430 - 437