Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology

被引:4
|
作者
Takahashi, Genichiro [1 ]
Demirel, Shaban [2 ]
Johnson, Chris A. [3 ]
机构
[1] Jikei Univ, Sch Med, Dept Ophthalmol, Katsushika Med Ctr, Tokyo, Japan
[2] Devers Eye Inst, Discoveries Sight Res Labs, Portland, OR USA
[3] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, 200 Hawkins Dr, Iowa City, IA 52242 USA
关键词
Visual fields; Glaucoma; Frequency doubling; Progression; VISUAL-FIELD DEFECTS; OCULAR HYPERTENSION; SPATIAL-FREQUENCY; MACAQUE MONKEY; GANGLION-CELLS; PROGRESSION; ILLUSION; LOSSES; TRIAL; EYES;
D O I
10.1007/s00417-016-3573-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To test the hypothesis that development of glaucomatous visual fields can be predicted several years earlier from prior visual field information. One-hundred and seven eyes with glaucomatous optic neuropathy (n = 47 eyes) or which were suspicious for glaucoma (n = 60) were prospectively enrolled in a longitudinal study. Visual fields were evaluated on an annual basis using standard automated perimetry (SAP), the original version of frequency doubling technology (FDT) perimetry, and a custom version of FDT that used the 24-2 stimulus pattern. All SAP fields were within normal limits at the initial visit. When the SAP glaucoma hemifield test was 'outside normal limits' or the pattern standard deviation probability was worse than the lower 5th percentile or more than two clustered locations at the p < 0.05 level were present on the pattern deviation probability plot, an eye was defined as being abnormal. We used a classification tree analysis to predict which eyes would convert, using only baseline test results. Classification trees that were constructed using only baseline data had excellent specificity (near 100%) but worse sensitivity (25-50%) for predicting which eyes would convert during follow-up. Predictive information is present in visual field results, even when they are still within normal limits.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 50 条
  • [21] Frequency doubling technology perimetry using a 24-2 stimulus presentation pattern
    Johnson, CA
    Cioffi, GA
    Van Buskirk, EM
    OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) : 571 - 581
  • [22] Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology
    Nishijima, Euido
    Hosaka, Daisuke
    Ogawa, Shumpei
    Itoh, Yoshinori
    Noro, Takahiko
    Okude, Sachiyo
    Sano, Kei
    Yoshikawa, Keiji
    Tatemichi, Masayuki
    Nakano, Tadashi
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (08):
  • [23] Long-term fluctuation of standard automatic perimetry, pulsar Perimetry and frequency-doubling technology in early glaucoma diagnosis
    Gonzalez-Hernandez, M.
    de la Rosa, M. Gonzalez
    de la Vega, R. Rodriguez
    Hernandez-Vidal, A.
    OPHTHALMIC RESEARCH, 2007, 39 (06) : 338 - 343
  • [24] Frequency doubling technology and high-pass resolution perimetry in glaucoma and ocular hypertension
    Kalaboukhova, L
    Lindblom, B
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2003, 81 (03): : 247 - 252
  • [25] Frequency Doubling Technology Perimetry and Changes in Quality of Life of Glaucoma Patients: A Longitudinal Study
    Abe, Ricardo Y.
    Gracitelli, Carolina P. B.
    Diniz-Filho, Alberto
    Zangwill, Linda M.
    Weinreb, Robert N.
    Medeiros, Felipe A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (01) : 114 - 122
  • [26] Visual Field Tests for Glaucoma Patients With Initial Macular Damage: Comparison Between Frequency-doubling Technology and Standard Automated Perimetry Using 24-2 or 10-2 Visual Fields
    Park, Hae-Young Lopilly
    Lee, Jiyoung
    Park, Chan Kee
    JOURNAL OF GLAUCOMA, 2018, 27 (07) : 627 - 634
  • [27] Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
    Schiavi, Costantino
    Tassi, Filippo
    Finzi, Alessandro
    Cellini, Andmauro
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [28] Identifying "Preperimetric'' Glaucoma in Standard Automated Perimetry Visual Fields
    Asaoka, Ryo
    Iwase, Aiko
    Hirasawa, Kazunori
    Murata, Hiroshi
    Araie, Makoto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) : 7814 - 7820
  • [29] Predictive value of frequency doubling technology perimetry for detecting glaucoma in a developing country
    Mansberger, SL
    Johnson, CA
    Cioffi, GA
    Choi, D
    Krishnadas, SR
    Srinivasan, M
    Balamurugan, V
    Kim, U
    Smith, SD
    Wilkins, JH
    Gritz, DC
    JOURNAL OF GLAUCOMA, 2005, 14 (02) : 128 - 134
  • [30] Combining Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry for Glaucoma Detection
    Mwanza, Jean-Claude
    Warren, Joshua L.
    Hochberg, Jessica T.
    Budenz, Donald L.
    Chang, Robert T.
    Ramulu, Pradeep Y.
    JOURNAL OF GLAUCOMA, 2015, 24 (08) : 561 - 567