共 52 条
Sensorless variable speed operation of doubly-fed reluctance wind generators
被引:4
作者:
Jovanovic, Milutin
[1
]
Ademi, Sul
[2
]
Binns, Richard
[1
]
机构:
[1] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Warwick, Warwick Mfg Grp, Coventry, W Midlands, England
关键词:
rotors;
reluctance generators;
machine vector control;
angular velocity control;
power convertors;
brushless machines;
machine control;
power generation control;
wind power plants;
wind turbines;
asynchronous generators;
shafts;
comprehensive comparative simulation;
sensorless controller;
precise speed reference tracking;
intrinsically decoupled real power responses;
reactive power responses;
grid-connected winding;
typical variable loading profiles;
narrow speed ranges;
laboratory emulated wind turbine;
sensorless variable speed operation;
doubly-fed reluctance wind generators;
improved flux vector orientated control scheme;
more robust flux vector orientated control scheme;
emerging doubly-fed reluctance generator;
shaft angular position;
computer-simulated;
fractional power electronics converter rating;
promising medium-speed brushless machine technology;
industrial communities;
appealing economical solution;
compromised reliability;
high maintenance requirements;
conventional wound rotor doubly-fed induction generators;
commercial wind turbines;
FED INDUCTION MACHINE;
CONTROL SCHEME;
DESIGN;
TURBINES;
PERFORMANCE;
DFIG;
MRAS;
D O I:
10.1049/iet-rpg.2020.0021
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
An improved and more robust flux vector orientated control scheme for an emerging doubly-fed reluctance generator without a shaft angular position or velocity sensor has been proposed, computer-simulated, and experimentally verified. Whilst retaining the cost and other advantages of using a fractional power electronics converter rating, this promising medium-speed brushless machine technology has been viewed by research and industrial communities as an appealing economical solution for the compromised reliability and high maintenance requirements associated with the presence of slip rings, brushes, and the failures prone three-stage gearbox of conventional wound rotor doubly-fed induction generators, traditionally deployed for commercial wind turbines. The comprehensive comparative simulation and test results obtained have been shown to agree very well undoubtedly demonstrating the good overall performance of the sensorless controller. A precise speed reference tracking with smooth, intrinsically decoupled real and reactive power responses of the grid-connected winding has been achieved for the typical variable loading profiles and narrow speed ranges (e.g. around $2:1$2:1 or so) of a laboratory emulated wind turbine.
引用
收藏
页码:2810 / 2819
页数:10
相关论文