Sensorless variable speed operation of doubly-fed reluctance wind generators

被引:4
作者
Jovanovic, Milutin [1 ]
Ademi, Sul [2 ]
Binns, Richard [1 ]
机构
[1] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Warwick, Warwick Mfg Grp, Coventry, W Midlands, England
关键词
rotors; reluctance generators; machine vector control; angular velocity control; power convertors; brushless machines; machine control; power generation control; wind power plants; wind turbines; asynchronous generators; shafts; comprehensive comparative simulation; sensorless controller; precise speed reference tracking; intrinsically decoupled real power responses; reactive power responses; grid-connected winding; typical variable loading profiles; narrow speed ranges; laboratory emulated wind turbine; sensorless variable speed operation; doubly-fed reluctance wind generators; improved flux vector orientated control scheme; more robust flux vector orientated control scheme; emerging doubly-fed reluctance generator; shaft angular position; computer-simulated; fractional power electronics converter rating; promising medium-speed brushless machine technology; industrial communities; appealing economical solution; compromised reliability; high maintenance requirements; conventional wound rotor doubly-fed induction generators; commercial wind turbines; FED INDUCTION MACHINE; CONTROL SCHEME; DESIGN; TURBINES; PERFORMANCE; DFIG; MRAS;
D O I
10.1049/iet-rpg.2020.0021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An improved and more robust flux vector orientated control scheme for an emerging doubly-fed reluctance generator without a shaft angular position or velocity sensor has been proposed, computer-simulated, and experimentally verified. Whilst retaining the cost and other advantages of using a fractional power electronics converter rating, this promising medium-speed brushless machine technology has been viewed by research and industrial communities as an appealing economical solution for the compromised reliability and high maintenance requirements associated with the presence of slip rings, brushes, and the failures prone three-stage gearbox of conventional wound rotor doubly-fed induction generators, traditionally deployed for commercial wind turbines. The comprehensive comparative simulation and test results obtained have been shown to agree very well undoubtedly demonstrating the good overall performance of the sensorless controller. A precise speed reference tracking with smooth, intrinsically decoupled real and reactive power responses of the grid-connected winding has been achieved for the typical variable loading profiles and narrow speed ranges (e.g. around $2:1$2:1 or so) of a laboratory emulated wind turbine.
引用
收藏
页码:2810 / 2819
页数:10
相关论文
共 52 条
  • [1] Performance analysis and testing of a 250 kW medium-speed brushless doubly-fed induction generator
    Abdi, Ehsan
    McMahon, Richard
    Malliband, Paul
    Shao, Shiyi
    Mathekga, Mmamolatelo Ezekiel
    Tavner, Peter
    Abdi, Salman
    Oraee, Ashknaz
    Long, Teng
    Tatlow, Mark
    [J]. IET RENEWABLE POWER GENERATION, 2013, 7 (06) : 631 - 638
  • [2] Model-free adaptive learning control scheme for wind turbines with doubly fed induction generators
    Abouheaf, Mohammed
    Gueaieb, Wail
    Sharaf, Adel
    [J]. IET RENEWABLE POWER GENERATION, 2018, 12 (14) : 1675 - 1686
  • [3] A New Sensorless Speed Control Scheme for Doubly Fed Reluctance Generators
    Ademi, Sul
    Jovanovic, Milutin G.
    Chaal, Hamza
    Cao, Wenping
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (03) : 993 - 1001
  • [4] Control of doubly-fed reluctance generators for wind power applications
    Ademi, Sul
    Jovanovic, Milutin
    [J]. RENEWABLE ENERGY, 2016, 85 : 171 - 180
  • [5] Control of Brushless Doubly-Fed Reluctance Generators for Wind Energy Conversion Systems
    Ademi, Sul
    Jovanovic, Milutin G.
    Hasan, Mohammed
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) : 596 - 604
  • [6] Vector Control Methods for Brushless Doubly Fed Reluctance Machines
    Ademi, Sul
    Jovanovic, Milutin G.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (01) : 96 - 104
  • [7] High-efficiency control of brushless doubly-fed machines for wind turbines and pump drives
    Ademi, Sul
    Jovanovic, Milutin
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 81 : 120 - 132
  • [8] Frequency support using doubly fed induction and reluctance wind turbine generators
    Attya, A. B.
    Ademi, S.
    Jovanovic, M.
    Anaya-Lara, O.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 101 : 403 - 414
  • [9] Introduction to the space vector modeling of the brushless doubly fed reluctance machine
    Betz, RE
    Jovanovic, MG
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2003, 31 (08) : 729 - 755
  • [10] Parametrically Robust Dynamic Speed Estimation Based Control for Doubly Fed Induction Generator
    Bhattarai, Rojan
    Gurung, Niroj
    Ghosh, Sudipta
    Kamalasadan, Sukumar
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (06) : 6529 - 6542